Yang Liu

Yang Liu

Auto-generated profile, based on publicly available information

Yang Liu

School of Instrumentation Science and Opto-electronics Engineering, Beihang University, Beijing, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2023 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
YLYang Liu
Yang Liu
Cheng LiCheng Li
Cheng Li
BLBuxuan Li
Buxuan Li
SLShanshan Lu
Shanshan Lu
SFShangchun Fan
Shangchun Fan
MSMengxian Shen
Mengxian Shen

13 August 2023 in Applied Surface Science
Verified
Journal Article
Closed access
WZwan zhen
wan zhen
Cheng LiCheng Li
Cheng Li
YLYang Liu
Yang Liu
YLYujian Liu
Yujian Liu
XXXi Xiao
Xi Xiao
SHSong Han
Song Han

19 January 2024 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
ZWZhen Wan
Zhen Wan
Cheng LiCheng Li
Cheng Li
RLRonghui Liu
Ronghui Liu
Wei ZhouWei Zhou
Wei Zhou
WFWenjing Fan
Wenjing Fan
YLYang Liu
Yang Liu

22 February 2024 in Carbon
Verified
Journal Article
Closed access
YLYang Liu
Yang Liu
Cheng LiCheng Li
Cheng Li
TMTiantian Ma
Tiantian Ma
Wei ZhouWei Zhou
Wei Zhou
SDShuxuan Dong
Shuxuan Dong
SFShangchun Fan
Shangchun Fan

2 June 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YLYang Liu
Yang Liu
Cheng LiCheng Li
Cheng Li
SLShanshan Lu
Shanshan Lu
SDShuxuan Dong
Shuxuan Dong
SFShangchun Fan
Shangchun Fan
Graphene-based Fabry-Perot (F-P) acoustic sensor exhibits excellent performance with high sensitivity and compact dimensions. However, temperature fluctuations compromise its thermal stability of sensitivity due to the changes in cavity length. Herein, a simple and portable graphene-based F-P acoustic sensor with quartz cavity structure (QCS) is developed to address this problem. Acoustic tests show that the cavity length change of the fabricated sensor with QCS is significantly decreased to 3.1 nm/°C in the tested range of 20–80 °C, 95 times smaller than a referenced F-P acoustic sensor with ceramic cavity structure (CCS). The measured frequency response variation (75.6% in the range of 0.1–18 kHz) and sensitivity variation (0.46%/°C at a typical frequency of 1 kHz) are 1.8 times and 2.3 times smaller than the results for the latter, respectively. Moreover, the maximum mechanical sensitivity (SM) at 20 °C is up to 395.99 nm/Pa@17 kHz in the aforementioned frequency range, which is at least 147% higher than the state-of-the-art F-P acoustic sensors reported previously. The as-fabricated temperature self-compensated sensor demonstrates potential for weak acoustic detection in varying temperature environments.

3 April 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WZwan zhen
wan zhen
Cheng LiCheng Li
Cheng Li
YLYang Liu
Yang Liu
ZWZhengwei Wu
Zhengwei Wu
SFShangchun Fan
Shangchun Fan
Photothermal graphene resonant sensors hold significant promise for micromechanical sensing due to their superior mechanical and thermal properties. This study investigates the resonant and thermal behaviors of graphene resonators under varying optical power and temperature conditions. We measured the thermal time constants of five-layer (5L), eight-layer (8L), ten-layer (10L) graphene resonators, observing increases by 71, 74, and 57 ns, respectively, as optical power increased from 1 to 5 mW, alongside temperature rises in the graphene films. Additionally, the corresponding thermal and mechanical properties were further examined across different ambient temperatures. Results show that the resonant frequency increases with temperature-induced surface tension, while increased tension enhances Umklapp scattering among phonons, reducing thermal conductivity. This work lays the groundwork for utilizing photothermal graphene resonators in mechanical sensing applications.