Matthieu Dietz

Matthieu Dietz

Auto-generated profile, based on publicly available information

Matthieu Dietz

Nuclear Medicine and Molecular Imaging Department, Lausanne University Hospital, Lausanne, Switzerland

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2020 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
MDMatthieu Dietz
Matthieu Dietz
GCGilles Chironi
Gilles Chironi
YCYann-Erick Claessens
Yann-Erick Claessens
RFRyan Lukas Farhad
Ryan Lukas Farhad
IRIsabelle Rouquette
Isabelle Rouquette
DTD. Tran
D. Tran

14 August 2021 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
MDMatthieu Dietz
Matthieu Dietz
CKChristel Hermann Kamani
Christel Hermann Kamani
EDEML des
EML des
Vincent DunetVincent Dunet
Vincent Dunet
PMPeriklis Mitsakis
Periklis Mitsakis
John PriorJohn Prior
John Prior
Background: Integrin alpha-V-beta-3 (αvβ3) pathway is involved in intraplaque angiogenesis and inflammation and represents a promising target for molecular imaging in cardiovascular diseases such as atherosclerosis. The aim of this study was to assess the clinical correlates of arterial wall accumulation of 68Ga-NODAGA-RGD, a specific αvβ3 integrin ligand for PET. Materials and methods: The data of 44 patients who underwent 68Ga-NODAGA-RGD PET/CT scans were retrospectively analyzed. Tracer accumulation in the vessel wall of major arteries was analyzed semi-quantitatively by blood-pool-corrected target-to-background ratios. Tracer uptake was compared with clinically documented atherosclerotic cardiovascular disease, cardiovascular risk factors and calcified plaque burden. Data were compared using the Mann–Whitney U test, Pearson correlation and Spearman correlation. Results: 68Ga-NODAGA-RGD arterial uptake was significantly higher in patients with previous clinically documented atherosclerotic cardiovascular disease (mean TBR 2.44 [2.03–2.55] vs. 1.81 [1.56–1.96], p = 0.001) and showed a significant correlation with prior cardiovascular or cerebrovascular event (r = 0.33, p = 0.027), BMI (ρ = 0.38, p = 0.01), plaque burden (ρ = 0.31, p = 0.04) and hypercholesterolemia (r = 0.31, p = 0.04). Conclusions: 68Ga-NODAGA-RGD holds promise as a non-invasive marker of disease activity in atherosclerosis, providing information about intraplaque angiogenesis.

11 May 2020 in Clinical Nuclear Medicine
Verified
Journal Article
Closed access
MDMatthieu Dietz
Matthieu Dietz
SNSophie Neyrand
Sophie Neyrand
ADAnthony Dhomps
Anthony Dhomps
MDMyriam Decaussin-Petrucci
Myriam Decaussin-Petrucci
JTJeremie Tordo
Jeremie Tordo
A 28-year old man, with previous history of chronic abdominal pain, was referred to our nuclear medicine center for an 18F-FDG PET/CT following the fortuitous discovery of a 48-mm right adrenal gland lesion of heterogeneous density at the CT scan. The PET/CT showed an isolated heterogeneous significant uptake evocative of neoplasia. Surprisingly, the anatomopathological analysis after surgery revealed an adenoid tumor of the adrenal gland. This case of a rare benign tumor can be a source of false-positive and mimicking malignancies in the exploration of adrenal lesions.

6 November 2023 in European Journal of Hybrid Imaging
Verified
Journal Article
Open access
PDF file
BMBianca Mazini
Bianca Mazini
MDMatthieu Dietz
Matthieu Dietz
BMBénédi Maréchal
Bénédi Maréchal
RCRicardo Corredor-Jerez
Ricardo Corredor-Jerez
John PriorJohn Prior
John Prior
Vincent DunetVincent Dunet
Vincent Dunet
Background: Small-vessel disease (SVD) plays a crucial role in cardiac and brain ischemia, but little is known about potential interrelation between both. We retrospectively evaluated 370 patients, aiming at assessing the interrelation between cardiac and brain SVD by using quantitative 82Rb cardiac PET/CT and brain MRI. Results: In our population of 370 patients, 176 had normal myocardial perfusion, 38 had pure cardiac SVD and 156 had obstructive coronary artery disease. All underwent both a cardiac 82Rb PET/CT and a brain 1.5T or 3T MRI. Left-ventricle myocardial blood flow (LV-MBF) and flow reserve (LV-MFR) were recorded from 82Rb PET/CT, while Fazekas score, white matter lesion (WMab) volume, deep gray matter lesion (GMab) volume, and brain morphometry (for z-score calculation) using the MorphoBox research application were derived from MRI. Groups were compared with Kruskal–Wallis test, and the potential interrelation between heart and brain SVD markers was assessed using Pearson’s correlation coefficient. Patients with cardiac SVD had lower stress LV-MBF and MFR (P < 0.001) than patients with normal myocardial perfusion; Fazekas scores and WMab volumes were similar in those two groups (P > 0.45). In patients with cardiac SVD only, higher rest LV-MBF was associated with a lower left-putamen (rho = − 0.62, P = 0.033), right-thalamus (rho = 0.64, P = 0.026), and right-pallidum (rho = 0.60, P = 0.039) z-scores and with a higher GMab volume. Lower stress LV-MBF was associated with lower left-caudate z-score (rho = 0.69, P = 0.014), while lower LV-MFR was associated with lower left (rho = 0.75, P = 0.005)- and right (rho = 0.59, P = 0.045)-putamen z-scores, as well as higher right-thalamus GMab volume (rho = − 0.72, P = 0.009). Conclusion: Significant interrelations between cardiac and cerebral SVD markers were found, especially regarding deep gray matter alterations, which supports the hypothesis of SVD as a systemic disease.

12 May 2023 in Pediatric Radiology
Verified
Journal Article
Open access
PDF file
MDMatthieu Dietz
Matthieu Dietz
NJNicolas Jacquet-Francillon
Nicolas Jacquet-Francillon
ABAlexandre Bani-Sadr
Alexandre Bani-Sadr
BCBoris Collette
Boris Collette
PMPierre-Yves Mure
Pierre-Yves Mure
AFAnthime FLAUS
Anthime FLAUS
Background: One of the main limitations of 99mtechnetium-dimercaptosuccinic acid (DMSA) scan is the long acquisition time. Objective: To evaluate the feasibility of short DMSA scan acquisition times using a cadmium-zinc-telluride-based single-photon emission computed tomography (SPECT) system in children. Materials and methods: The data of 27 children (median age: 4 years; 16 girls) who underwent DMSA SPECT were retrospectively analyzed. Both planar and SPECT DMSA were performed. SPECT images were analyzed using coronal-simulated planar two-dimensional images. A reduction in SPECT acquisition time was simulated to provide 4 series (SPECT-15 min, SPECT-10 min, SPECT-5 min and SPECT-2.5 min). A direct comparison of the planar and SPECT series was performed, including semi-quantification reproducibility, image quality (mean quality score on a scale of 0 to 2) and inter- and intra-observer reproducibility of the scintigraphic patterns. Results: The overall image quality score (± standard deviation) was 1.3 (± 0.6) for the planar data set, 1.6 (± 0.5) for the SPECT-15 min data set, 1.4 (± 0.5) for the SPECT-10 min data set, 1.0 (± 0.5) for the SPECT-5 min data set and 0.6 (± 0.6) for the SPECT-2.5 min data set. Median Kappa coefficients for inter-observer agreement between planar and SPECT images were greater than 0.83 for all series and all readers except one reader for the SPECT-2.5 min series (median Kappa coefficient = 0.77). Conclusion: Shortening SPECT acquisitions to 5 min is feasible with minimal impact on images in terms of quality and reproducibility. Graphical

2 December 2021 in Research Square
Verified
Preprint
Open access
PDF file
MDMatthieu Dietz
Matthieu Dietz
CKChristel H Kamani
Christel H Kamani
GAGilles Allenbach
Gilles Allenbach
VRVladimir Rubimbura
Vladimir Rubimbura
SFStephane Fournier
Stephane Fournier
John PriorJohn Prior
John Prior
Purpose The aim of this study was to assess the most reliable quantitative variable on Rubidium-82 (82Rb) cardiac PET/CT for predicting major adverse cardiovascular events (MACE), on the latest PET camera using silicon photomultipliers digital readout (SiPM) technology. Methods We prospectively enrolled 274 consecutive participants with suspected myocardial ischemia. Participants underwent 82Rb cardiac SiPM PET/CT and were followed-up for MACE over 652 days (interquartile range: 559 to 751 days). For each participant, global and regional myocardial flow reserve (MFR), stress myocardial blood flow (stress MBF) and their combination as myocardial flow capacity radius (MFC radius) were measured. Results On receiver operator curve analysis, MACE prediction was similar for global and regional MFR, stress MBF, and MFC radius (area under the curve; (i) Global: 0.70 vs. 0.71 and 0.73, and (ii) Regional: 0.71 vs. 0.71 and 0.73, respectively, p > 0.1 for all pairwise comparisons). On multivariable analysis, (i) Global: MFR < 1.98, stress MBF < 1.94 mL/g/min, and MFC radius < 3.12, as well as (ii) Regional: MFR < 1.75, stress MBF < 1.75 mL/g/min, and MFC radius < 2.7, emerged all as similar independent predictors of MACE (p < 0.001 for all). Conclusions Using the latest SiPM PET technology with 82Rb, global and regional MFR, stress MBF, and MFC radius are similar powerful predictors of cardiovascular event.