28 May 2024 in Dalton Transactions
Zr(iv), Ce(iv), and Hf(iv), and the linkers BDC and PDC has been fully studied for the CO2 adsorption capability.
1 September 2021 in Applied Catalysis A: General
7 December 2022 in Environmental Science: Water Research & Technology
Sewage sludge (SS) management constitutes both a challenge and an opportunity for the sustainability of wastewater treatment plants (WWTPs). Standalone anaerobic digestion (AD) stabilizes the biodegradable organics contained in SS but recovers only a fraction of the chemical energy stored therein and produces large amounts of un-stabilized sludge. Hydrothermal liquefaction (HTL) coupled with AD can enhance the treatment and energy recovery of SS. Standalone AD was compared against (1) an HTL–AD configuration, with SS as HTL input, and the generated aqueous product (AP) as AD input; and (2), an AD–HTL–AD configuration, with SS as AD input, the digestate as HTL input, and the generated AP as AD input. Both configurations decreased the SS' COD from 27.5 to 0.6 g L−1, while the overall energy recovered was increased up to 2.2-fold relative to conventional SS treatment using only AD. Under the HTL–AD configuration, biocrude yields were higher (i.e., 26.4 vs. 15.8) and the AP generated was more biodegradable (0.78 vs. 0.65), than those obtained under the AD–HTL–AD configuration. Monte Carlo uncertainty analyses confirmed that overall energy recoveries would follow the order AD–HTL–AD > HTL–AD > AD; with energy recoveries (95% confidence) between, 63.5–94.7%, 54.6–91.2%, and 33.2–71.1%, respectively. This study shows that, by implementing HTL as a standalone SS treatment, WWTPs can recover more energy than using AD alone. Furthermore, WWTPs with existing AD would recover additional energy through HTL of the generated digestate, significantly reducing the environmental impacts and costs of conventional solids management.
1 May 2011 in Applied Catalysis A: General
30 July 2020 in New Journal of Chemistry
The benzaldehyde acetalization reaction catalyzed by UiO-66, and its fluorinated analog UiO-66F, was carried out in a batch-type reactor at room temperature and atmospheric pressure, and the full kinetic study was performed using the Langmuir–Hinshelwood and Eley–Rideal models. It was established that the Eley–Rideal model is the one that best fits the experimental data. The catalytic results indicated that both MOFs enable carrying out the acetalization reaction. However, UiO-66F has the highest activity, which could be attributed to its high acidity. Both structures were characterized by N2 physisorption, thermogravimetry, powder X-ray diffraction, potentiometric titrations, and infrared spectroscopy. The highest acidity displayed by UiO-66F was explained by DFT studies and experimental studies.
20 October 2016 in Biotechnology Letters