Sarah Jeuthe

Sarah Jeuthe

Auto-generated profile, based on publicly available information

Sarah Jeuthe

Department of Internal Medicine / Cardiology, Charité-Universitätsmedizin Berlin, Berlin, Germany

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
SJSarah Jeuthe
Sarah Jeuthe
KWKatharina Wassilew
Katharina Wassilew
DHDarach O H-Ici
Darach O H-Ici
TSTiago Ferreira da Silva
Tiago Ferreira da Silva
FMFrédéric Muench
Frédéric Muench
DMDaniel R. Messroghli
Daniel R. Messroghli
Cardiovascular magnetic resonance offers both diagnostic and prognostic information in myocarditis. Using an established animal model of myocarditis, the aim of this study was to measure myocardial T1 before the onset, in the acute and in the chronic phases of the disease and to compare its course with histological and immunohistochemistry findings. Male young Lewis rats were immunized with 0.25 mg porcine myocardial myosin into the rear footpads on day 0. Native and contrast-enhanced ECG-triggered cardiac MRI examinations were performed before immunization on day 0 and on days 14, 21 and 35. Left ventricular function, pre- and post- contrast T1 parameters and LGE images were assessed using Small animal look-locker inversion recovery (SALLI). For each of the indicated time points a minimum of 4 rats were randomly sacrificed for pathological investigations including conventional histology (HE and Sirius-Red staining) and immunohistochemistry (CD 68) investigations. All immunized rats developed myocarditis (morbidity 100 %). Histologically we observed increased wall thickness with biventricular macrophage-rich mixed inflammatory infiltrates. All rats with a histologically severe myocarditis showed increased native T1 and decreased post-contrast T1 of the myocardium. The assessment of native T1 and post-contrast T1 allows accurate differentiation between healthy myocardium and myocardium with inflammation and also between the acute and chronic phases of the disease.

23 August 2017 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
TLTomas Lapinskas
Tomas Lapinskas
JGJana Grune
Jana Grune
SZSeyedeh Mahsa Zamani
Seyedeh Mahsa Zamani
SJSarah Jeuthe
Sarah Jeuthe
DMDaniel Messroghli
Daniel Messroghli
SKSebastian Kelle
Sebastian Kelle
Cardiovascular magnetic resonance feature tracking (CMR-FT) is a novel tissue tracking technique developed for noninvasive assessment of myocardial motion and deformation. This preliminary study aimed to evaluate the observer’s reproducibility of CMR-FT in a small animal (mouse) model and define sample size calculation for future trials. Six C57BL/6 J mice were selected from the ongoing experimental mouse model onsite and underwent CMR with a 3 Tesla small animal MRI scanner. Myocardial deformation was analyzed using dedicated software (TomTec, Germany) by two observers. Left ventricular (LV) longitudinal, circumferential and radial strain (EllLAX, EccSAX and ErrSAX) were calculated. To assess intra-observer agreement data analysis was repeated after 4 weeks. The sample size required to detect a relative change in strain was calculated. In general, EccSAX and EllLAX demonstrated highest inter-observer reproducibility (ICC 0.79 (0.46–0.91) and 0.73 (0.56–0.83) EccSAX and EllLAX respectively). In contrast, at the intra-observer level EllLAX was more reproducible than EccSAX (ICC 0.83 (0.73–0.90) and 0.74 (0.49–0.87) EllLAX and EccSAX respectively). The reproducibility of ErrSAX was weak at both observer levels. Preliminary sample size calculation showed that a small study sample (e.g. ten animals to detect a relative 10% change in EccSAX) could be sufficient to detect changes if parameter variability is low. This pilot study demonstrates good to excellent inter- and intra-observer reproducibility of CMR-FT technique in small animal model. The most reproducible measures are global circumferential and global longitudinal strain, whereas reproducibility of radial strain is weak. Furthermore, sample size calculation demonstrates that a small number of animals could be sufficient for future trials.

4 October 2014 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
DHDarach O H-Ici
Darach O H-Ici
SJSarah Jeuthe
Sarah Jeuthe
TDThore Dietrich
Thore Dietrich
FBFelix Berger
Felix Berger
TKTitus Kuehne
Titus Kuehne
DMDaniel R. Messroghli
Daniel R. Messroghli