Titus Kuehne

Titus Kuehne

Auto-generated profile, based on publicly available information

Titus Kuehne

Charité - Universitätsmedizin Berlin, Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Germany (S.N., M. Kelm, T.K.)

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2008 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
NBNarendra K. Bodhey
Narendra K. Bodhey
PBPhilipp Beerbaum
Philipp Beerbaum
SSSamir Sarikouch
Samir Sarikouch
SKSiegfried Kropf
Siegfried Kropf
PLPeter Lange
Peter Lange
TKTitus Kuehne
Titus Kuehne
Anatomic and functional observations suggest that the right ventricle (RV) can be analyzed in terms of its inlet, apical trabecular, and outlet components. Our study was designed to evaluate the regional adaptation of these components to different conditions of loading, with additional analysis of the surgical techniques used for primary repair. We studied prospectively 45 patients with tetralogy of Fallot (age, 20.5+/-8.1 years) and 24 control subjects (age, 20.1+/-5.8 years). All subjects were studied by using cardiac MRI. End-diastolic (EDV), end-systolic (ESV), stroke volumes (SV), and ejection fraction (EF) were determined for the overall RV and separately for its inlet, apical trabecular, and outlet components. The patients had pulmonary regurgitant fractions of 33.2+/-11.1%, and RV peak-systolic pressures of 40.7+/-16.1 mm Hg. In controls, the apical trabecular component EDV was 51.5+/-11.1 mL/m(2) (54.3+/-6.8% of the total RV EDV), ESV was 19.2+/-6.3 mL/m(2) (47.6+/-10.5% of RV ESV), and SV was 32.3+/-6.9 mL/m(2) (58.9+/-6.6% of RV SV), resulting in an EF of 63.1+/-7.7%. When considering all patients, the apical trabecular component took up the greatest part of the overload, having an EDV of 76.5+/-18.1 mL/m(2), and an ESV of 31.6+/-12.8 mL/m(2), reflecting an increase of 49 and 67% over controls, respectively (P<0.001). EF was 59.7+/-10.7%, and was maintained at control levels (P=0.132). In controls, the outlet had considerable ejecting force, with an EF of 54.8+/-9.1%, whereas it was decreased in the patients with tetralogy (EF=28.5+/-11.9%). There was significant increase of ESV (P<0.001), but not of EDV, with EF decreased by 45% (P<0.001). The inlet was not significantly affected by overload. The surgical technique did not significantly affect any measured parameter for any component. In patients with tetralogy of Fallot, subsequent to surgical correction, the individual components of the RV respond in characteristic fashion to RV overload.

1 September 2014 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
EREugénie Riesenkampff
Eugénie Riesenkampff
JFJoao Filipe Fernandes
Joao Filipe Fernandes
SMSebastian Meier
Sebastian Meier
LGLeonid Goubergrits
Leonid Goubergrits
SKSiegfried Kropf
Siegfried Kropf
TKTitus Kuehne
Titus Kuehne

1 January 2012 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
IVIsrael Valverde
Israel Valverde
SNSarah Nordmeyer
Sarah Nordmeyer
SUsergio uribe
sergio uribe
GGGerald Greil
Gerald Greil
FBFelix Berger
Felix Berger
PBPhilipp Beerbaum
Philipp Beerbaum
Systemic-to-pulmonary collateral flow (SPCF) may constitute a risk factor for increased morbidity and mortality in patients with single-ventricle physiology (SV). However, clinical research is limited by the complexity of multi-vessel two-dimensional (2D) cardiovascular magnetic resonance (CMR) flow measurements. We sought to validate four-dimensional (4D) velocity acquisition sequence for concise quantification of SPCF and flow distribution in patients with SV.

1 August 2005 in Heart
Verified
Journal Article
Open access
PDF file
TKT Kuehne
T Kuehne
SYS Yilmaz
S Yilmaz
ISI Schulze-Neick
I Schulze-Neick
EWE Wellnhofer
E Wellnhofer
PEP Ewert
P Ewert
PLP Lange
P Lange
Objectives: To validate in vivo a magnetic resonance imaging (MRI) method for measurement of pulmonary vascular resistance (PVR) and subsequently to apply this technique to patients with pulmonary hypertension (PHT). Methods and results: PVR was assessed from velocity encoded cine MRI derived pulmonary artery (PA) flow volumes and simultaneously determined invasive PA pressures. For pressure measurements flow directed catheters were guided under magnetic resonance fluoroscopy at 1.5 T into the PA. In preliminary validation studies (eight swine) PVR was determined with the thermodilution technique and compared with PVR obtained by MRI (0.9 (0.5) v 1.1 (0.3) Wood units·m2, p = 0.7). Bland-Altman test showed agreement between both methods. Inter-examination variability was high for thermodilution (6.2 (2.2)%) but low for MRI measurements (2.1 (0.3)%). After validation, the MRI method was applied in 10 patients with PHT and five controls. In patients with PHT PVR was measured at baseline and during inhalation of nitric oxide. Compared with the control group, PVR was significantly increased in the PHT group (1.2 (0.8) v 13.1 (5.6) Wood units·m2, p < 0.001) but decreased significantly to 10.3 (4.6) Wood units·m2 during inhalation of nitric oxide (p < 0.05). Inter-examination variability of MRI derived PVR measurements was 2.6 (0.6)%. In all experiments (in vivo and clinical) flow directed catheters were guided successfully into the PA under MRI control. Conclusions: Guidance of flow directed catheters into the PA is feasible under MRI control. PVR can be determined with high measurement precision with the proposed MRI technique, which is a promising tool to assess PVR in the clinical setting.

1 September 2010 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
BSBoris Schmitt
Boris Schmitt
PSPaul Steendijk
Paul Steendijk
SOStanislav Ovroutski
Stanislav Ovroutski
KLKarsten Lunze
Karsten Lunze
PRPedram Rahmanzadeh
Pedram Rahmanzadeh
TKTitus Kuehne
Titus Kuehne
Background—: The role, interplay, and relative importance of the multifactorial hemodynamic and myocardial mechanisms causing dysfunction of the Fontan circulation remain incompletely understood. Methods and Results—: Using an MRI catheterization technique, we performed a differential analysis of pulmonary vascular resistance and aortopulmonary collateral blood flow in conjunction with global ventricular pump function, myocontractility (end-systolic pressure-volume relation), and diastolic compliance (end-diastolic pressure-volume relation) in 10 patients with a Fontan circulation at rest and during dobutamine stress. Pulmonary and ventricular pressures were measured invasively and synchronized with velocity-encoded MRI-derived pulmonary and aortic blood flows and cine MRI-derived ventricular volumes. Pulmonary vascular resistance and end-systolic and end-diastolic pressure-volume relations were then determined. Aortopulmonary collateral flow was calculated as the difference between aortic and pulmonary flow. Compared to rest, dobutamine caused a small increase in mean pulmonary pressures ( P <0.05). Collateral flow was significantly augmented ( P <0.001) and contributed importantly to an increase in pulmonary flow ( P <0.01). Pulmonary vascular resistance decreased significantly ( P <0.01). Dobutamine did not increase stroke volumes significantly despite slightly enhanced contractility (end-systolic pressure-volume relation). Active early relaxation (τ) was inconspicuous, but the end-diastolic pressure-volume relation shifted upward, indicating reduced compliance. Conclusions—: In patients with a Fontan circulation, aortopulmonary collateral flow contributes substantially to enhanced pulmonary flow during stress. Our data indicate that pulmonary vascular response to augmented cardiac output was adequate, but decreased diastolic compliance was identified as an important component of ventricular dysfunction.

30 July 2010 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
DMDaniel R Messroghli
Daniel R Messroghli
ARAndre Rudolph
Andre Rudolph
HAHassan Abdel-Aty
Hassan Abdel-Aty
RWRalf Wassmuth
Ralf Wassmuth
TKTitus Kühne
Titus Kühne
JSJeanette Schulz-Menger
Jeanette Schulz-Menger
In magnetic resonance (MR) imaging, T1, T2 and T2* relaxation times represent characteristic tissue properties that can be quantified with the help of specific imaging strategies. While there are basic software tools for specific pulse sequences, until now there is no universal software program available to automate pixel-wise mapping of relaxation times from various types of images or MR systems. Such a software program would allow researchers to test and compare new imaging strategies and thus would significantly facilitate research in the area of quantitative tissue characterization.