Qiang Chi

Qiang Chi

Auto-generated profile, based on publicly available information

Qiang Chi

LIST, Key Laboratory of New Generation Artificial Intelligence Technology and Its Interdisciplinary Applications, Ministry of Education, and Jiangsu Provincial Joint International Research Laboratory of Medical Information Processing, Southeast University, Nanjing, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YLYuhang Liu
Yuhang Liu
HSHuazhong Shu
Huazhong Shu
QCQiang Chi
Qiang Chi
YZYue Zhang
Yue Zhang
ZLZidong Liu
Zidong Liu
ZGZhiguo Gui
Zhiguo Gui
Low-dose computed tomography (LDCT) reduces radiation exposure but suffers from high noise, impacting image quality and diagnostic accuracy. Supervised learning has helped address this challenge but requires numerous paired datasets of LDCT and normal-dose CT (NDCT) images, which limits their clinical practice. This article proposes a novel self-supervised disentangled convolutional neural network (SDCNN) that can directly reconstruct high-quality CT images from LDCT data without the need for a clean reference. Unlike other methods that treat noise as a uniform entity, SDCNN disentangles LDCT images into noise-free images, signal-dependent noise, and signal-independent noise, aligning with the intrinsic principles of low-dose noise generation. To enhance the purity of disentanglement, we introduce the concept of combination and re-disentanglement to establish a training framework based on SDCNN. Additionally, we design self-supervised loss functions, including novel anisotropic total variation (TV) and distance loss functions, to improve the efficiency of the denoising process. The signal-guided attention (SGA) module effectively captures the relationship between signal-dependent noise and the signal across both spatial and channel dimensions. Experiments on clinical and animal data demonstrate that the proposed method performed better than all competing state-of-the-art (SOTA) self-supervised algorithms in noise and artifact removal. For example, compared to the self-supervised algorithms, SDCNN improves the multiscale structural similarity (MSSIM), peak signal-to-noise ratio (PSNR), and feature similarity (FSIM) by at least 2.26%, 1.20 dB, 1.23%, whereas, the gradient magnitude similarity deviation (GMSD) is reduced by at least 1.11% on the Mayo clinical data. The code is available at https://github.com/YuhangLiu98/SDCNN .

24 November 2025 in Expert Systems with Applications
Verified
Journal Article
Closed access
YLYuhang Liu
Yuhang Liu
HSHuazhong Shu
Huazhong Shu
QCQiang Chi
Qiang Chi
YZYue Zhang
Yue Zhang
ZLZidong Liu
Zidong Liu
ZGZhiguo Gui
Zhiguo Gui