26 September 2018 in IEEE Transactions on Circuits and Systems I: Regular Papers
An ultra-low power electrocardiogram (ECG) processing architecture with an adequate level of accuracy is a necessity for Internet of Things (IoT) medical wearable devices. This paper presents a novel real-time QRS detector and an ECG compression architecture for IoT healthcare devices. An absolute-value curve length transform (A-CLT) is proposed that effectively enhances the QRS complex detection with minimized hardware resources. The proposed architecture requires adders, shifters, and comparators only, and removes the need for any multipliers. QRS detection was accomplished by using adaptive thresholds in the A-CLT transformed ECG signal, and achieved a sensitivity of 99.37% and the predictivity of 99.38% when validated using Physionet ECG database. Furthermore, a lossless compression technique was incorporated into the proposed architecture that uses the ECG signal first derivative and entropy encoding. An average compression ratio of 2.05 was achieved when evaluated using MIT-BIH database. The proposed QRS detection architecture deals with almost all the ECG signal artifacts, such as low-frequency noise, baseline drift, and high-frequency interference with minimum hardware resources. The proposed QRS architecture was synthesized using 65-nm low-power process using standard-cell-based flow. The power consumption of the design was 6.5 nW while operating at a supply of 1 V and a frequency of 250 Hz. Moreover, the system could benefit from duty-cycling.
12 May 2017 in IEEE Transactions on Circuits and Systems I: Regular Papers
Internet of Things (IoT) promises to revolutionize the health-care sector through remote, continuous, and non-invasive monitoring of patients. However, there are two main challenges faced by the IoT-enabled medical devices: energy-efficiency and security/privacy concerns. Researchers have independently attempted to develop solutions, such as low-power ECG-processors and security protocols, that address these challenges on an individual basis. However, it is imperative to investigate holistic solutions that integrate in a synergistic manner, delivering an overall secure and energy-efficient product. In this paper, we develop an ultra-low power and secure IoT sensing/pre-processing platform for prediction of ventricular arrhythmia using ECG signals. Our proposed solution is able to predict the on-set of the critical cardiovascular events upto 3 h in advance with 86% accuracy. Moreover, the proposed architecture is designed using an Application Specific Integrated Circuits design flow in 65-nm Low Power Enhanced technology; the power it consumes is 62.2% less than that of the state-of-the-art approaches, while occupying 16.0% smaller area. The proposed processor makes use of ECG signals to extract a chip-specific ECG key that enables protection of communication channel. By integrating the ECG key with an existing design-for-trust solution, the proposed platform offers protection also at the hardware level, thwarting hardware security threats, such as reverse engineering and counterfeiting. Through efficient sharing of on-chip resources, the overhead of the multi-layered security infrastructure is kept at 9.5% for area and 0.7% for power with no impact on the speed of the design.
12 July 2018 in IEEE Transactions on Biomedical Circuits and Systems
This paper presents an electrocardiogram (ECG) processor on chip for full ECG feature extraction and cardiac autonomic neuropathy (CAN) classification. Full ECG extraction is performed using absolute value curve length transform (A-CLT) for QRS peak detection and using low-pass differentiation for other ECG features such as QRS on , QRS off , P wave , and T wave . The proposed QRS detector attained a sensitivity of 99.37% and predictivity of 99.38%. The extracted QRS peak to QRS peak intervals (RR intervals) along with QT intervals enable CAN severity detection, which is a cardiac arrhythmia usually seen in diabetic patients leading to increased risk of sudden cardiac death. This paper presents the first hardware real-time implementation of CAN severity detector that is based on RR variability and QT variability analysis. RR variability metrics are based on mean RR interval and root mean square of standard differences of the RR intervals. The proposed architecture was implemented in 65-nm technology and consumed 75 nW only at 0.6 V, when operating at 250 Hz. Ultralow power dissipation of the system enables it to be integrated into wearable healthcare devices.
18 February 2019 in Analog Integrated Circuits and Signal Processing
12 March 2019 in Analog Integrated Circuits and Signal Processing