Qiang Yi

Qiang Yi

Auto-generated profile, based on publicly available information

Qiang Yi

China Acad Engn Phys, Inst Nucl Phys & Chem, Mianyang 621900, Peoples R China

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2004 in Color Research & Application
Verified
Journal Article
Open access
PDF file
TST. Suzuki
T. Suzuki
QYQ. Yi
Q. Yi
SSS. Sakuragawa
S. Sakuragawa
HTH. Tamura
H. Tamura
KOK. Okajima
K. Okajima
We measured response time, the number of nonresponses, response error, and subjective visibility evaluation for color Landolt‐Cs with a gray color background presented on a CRT display to young and old adults (mean ages: 22.3 and 65.9 years, respectively) and to the same young adults wearing glasses with filters simulating an aging human crystalline lens. Comparing the results of elderly and young subjects without the filter, the results of the elderly subjects showed a longer response time, higher nonresponse ratio, slower response speed, and lower visibility, particularly for gray and blue stimuli. Conversely, the results for the young subjects who were fitted with the filters showed tendencies similar to those of the elderly subjects. These results indicate that the yellowing of the human lens strongly influences the visibility of color targets in the elderly and that wearing the filters enables young adults to simulate the visibility of the elderly. It suggests that the simulated filter as well as the aging human lens modifies the effective luminance, effective luminance contrast, and color difference between the color target and the background on the retina. Moreover, the relationship between the subjective evaluation and the response speed changes remarkably with age, regardless of the filters, suggesting that not only the subjective evaluation but also the evaluation of the performance, such as response speed, is important in estimating visibility and controllability in the elderly. The filter used in the present study will be an effective tool for the young to evaluate the visibility of elderly adults in terms of both response speed and subjective evaluation of visibility. © 2004 Wiley Periodicals, Inc. Col Res Appl, 30, 5–12, 2005; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/col.20071

1 December 2021 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
SMS. J. Meng
S. J. Meng
FYF. Ye
F. Ye
ZXZ. P. Xu
Z. P. Xu
XYX. S. Yan
X. S. Yan
SJS. Q. Jiang
S. Q. Jiang
ZLZ. H. Li
Z. H. Li
A study of the evolution and structure of magnetically driven converging radiative shock waves generated in Z-pinch foil liner implosion at an 8-MA pulsed-power facility is presented. End-on extreme ultraviolet images show an inward propagating shock that is circular to <±5% as a function of azimuthal angle, with a standard deviation in the emission intensity of <±30%, implying good cylindrical symmetry. The launch time and shock trajectory are determined by linear fitting of the measured data, giving a shock speed of Mach 6. One-dimensional radiation hydrodynamics MULTI-IFE-Z simulations agree with the experimental observations qualitatively and confirm the existence of a radiative precursor. It is demonstrated with experiment and simulation that the radiative shock wave is generated by magnetic piston compression of dense plasma shell. Analytic estimates of the post-shock plasma conditions suggest that these Z-pinch magnetically-driven high-Mach shocks are strongly radiatively cooled. It is applicable to the optically thick downstream, optically thin upstream radiative shock regime; thus, it can be described by three-layer model, which potentially could be applied to scale studies of astrophysical shocks in the laboratory.

1 October 2020 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
QYQiang Yi
Qiang Yi
HGHongsheng Guo
Hongsheng Guo
QHQingyuan Hu
Qingyuan Hu
SMShijian Meng
Shijian Meng
JYJianlun Yang
Jianlun Yang
ZLZhenghong Li
Zhenghong Li
The thermonuclear yield from deuterium-filled capsule implosions driven by Z-pinch dynamic hohlraums on an 8-MA pulsed power facility is diagnosed by Ag activation and neutron time-of-flight (nTOF). However, both detector systems suffer from an excessive bremsstrahlung background. Tests on the Ag activation system suggest that the facility may produce such an intense super-MeV x-ray background that the resulting photonuclear-excitation reactions can overwhelm the potential neutron signal. In the nTOF detectors, the high bremsstrahlung background generates such an excessive afterglow in the scintillator that confirming any thermonuclear yield may require a liquid scintillator with a much lower afterglow together with a gated photomultiplier.

1 August 2021 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
QYQiang Yi
Qiang Yi
SMShijian Meng
Shijian Meng
JYJianlun Yang
Jianlun Yang
QHQingyuan Hu
Qingyuan Hu
WYWenhao You
Wenhao You
ZLZhenghong Li
Zhenghong Li
In ongoing attempts to generate thermonuclear neutrons with the Z-pinch dynamic hohlraum concept at an 8-MA pulsed power facility, it has become possible to determine an upper limit for the neutron yield. The neutron time-of-flight diagnostic uses thick Pb shields and a specifically formulated fast liquid scintillator coupled to gated photomultiplier tubes to mitigate the hard bremsstrahlung x-ray (HXR) background that would otherwise overwhelm a potential neutron signal, and its suppression gives an upper-limit estimation for the neutron yield. A slow-neutron detector in the form of a BF3 counting system suggests a lower limit to the neutron yield although the early HXR pulse interference requires further confirmation as to whether the subsequent multiple pulses are induced by neutrons. Together, these measurements suggest a neutron-yield upper limit of 1.1×107 .

9 December 2024 in Physical Review E
Verified
Journal Article
Closed access
QYQiang Yi
Qiang Yi
FYFan Ye
Fan Ye
JLJian Lu
Jian Lu
XYXiaosong Yan
Xiaosong Yan
RYRuihua Yang
Ruihua Yang
XZXiuwen Zhou
Xiuwen Zhou
In this research, <^>0.14-micron-thick aluminum tamped by plastic is heated up to <^>110 eV by the x-ray pulse from the Z-pinch-driven dynamic Hohlraum on an 8-MA machine in China. After an <^>6 - ns heating stage, higher-energy xrays from an <^>2 - ns- long backlight pulse pass through the hot aluminum. The transmission is estimated by comparing the radiation passing through the aluminum sample in one shot with the radiation through only the plastic in another shot, with the x-ray spectra obtained using an elliptically bent concave crystal spectrometer. The transmission reveals features corresponding to x-ray absorption in Li-like and a series of He-like aluminum ions that provide values for its temperature and density. One method involves using a tabulated opacity database, while the other involves analyzing the line shapes and line ratios of the absorption features. The challenges in these measurements are discussed both theoretically and experimentally.

1 March 2023 in AIP Advances
Verified
Journal Article
Open access
PDF file
QYQiang Yi
Qiang Yi
SMShijian Meng
Shijian Meng
FYFan Ye
Fan Ye
JLJian Lu
Jian Lu
XYXiaosong Yan
Xiaosong Yan
ZLZhenghong Li
Zhenghong Li
This paper reports some important properties of a dynamic hohlraum radiation source intended to study the high-temperature opacity of medium-Z atoms. The time-resolved axial radiation power in two x-ray diodes gives the time-evolution of an equivalent black-body temperature that peaks at ∼260 eV at stagnation. Time-gated framing pinhole images show that the source comprises an intense high-temperature core that lasts for ∼2 ns preceded by a 10-ns-long lower-temperature implosion phase that emits mostly softer x rays. Combining pinhole images with soft x-ray power gives a time-resolved brightness radiation temperature that reaches 130 eV. Thus, the lower-temperature source could ionize an opacity sample, then the intense high-temperature radiation pulse could measure its opacity. Likewise, the time-integrated spectrum measured with a spherically bent crystal spectrometer is compatible with multiple blackbodies with different temperatures, from 176 to 185 eV. These characterizations suggest that this dynamic hohlraum can be used for high-temperature opacity measurements.