12 August 2020 in Nuclear Fusion
1 December 2021 in Physics of Plasmas
A study of the evolution and structure of magnetically driven converging radiative shock waves generated in Z-pinch foil liner implosion at an 8-MA pulsed-power facility is presented. End-on extreme ultraviolet images show an inward propagating shock that is circular to <±5% as a function of azimuthal angle, with a standard deviation in the emission intensity of <±30%, implying good cylindrical symmetry. The launch time and shock trajectory are determined by linear fitting of the measured data, giving a shock speed of Mach 6. One-dimensional radiation hydrodynamics MULTI-IFE-Z simulations agree with the experimental observations qualitatively and confirm the existence of a radiative precursor. It is demonstrated with experiment and simulation that the radiative shock wave is generated by magnetic piston compression of dense plasma shell. Analytic estimates of the post-shock plasma conditions suggest that these Z-pinch magnetically-driven high-Mach shocks are strongly radiatively cooled. It is applicable to the optically thick downstream, optically thin upstream radiative shock regime; thus, it can be described by three-layer model, which potentially could be applied to scale studies of astrophysical shocks in the laboratory.
1 April 2020 in Journal of Instrumentation
Routine diagnostics of total x-ray energy and peak power at an 8-MA pulsed-power generator in China will be described, together with calibrations. Successfully measurements with those diagnostics in Z-pinch dynamic hohlraum at low radiation temperature of similar to 70 eV were provided. Also presented are results from a flat response x-ray diode (XRD) for comparison. It is found that, in such an application, total x-ray energy from free-standing (FS) bolometer agrees well with that by scintillant power meter (SPM), but twice higher than that by XRD. This discrepancy lies in low spectral sensitivity of the flat response XRD and diffraction effect of pinhole array at low energy, confirmed by calculation and calibration. X-ray peak power from SPM agrees with that from XRD and diamond photo-conducting detector (PCD) within 10% and 20% deviation, respectively. We suggest that the SPM would be the preferred choice for both measurements for diagnosing low-radiation-temperature x-ray source.
1 August 2021 in Physics of Plasmas
In ongoing attempts to generate thermonuclear neutrons with the Z-pinch dynamic hohlraum concept at an 8-MA pulsed power facility, it has become possible to determine an upper limit for the neutron yield. The neutron time-of-flight diagnostic uses thick Pb shields and a specifically formulated fast liquid scintillator coupled to gated photomultiplier tubes to mitigate the hard bremsstrahlung x-ray (HXR) background that would otherwise overwhelm a potential neutron signal, and its suppression gives an upper-limit estimation for the neutron yield. A slow-neutron detector in the form of a BF3 counting system suggests a lower limit to the neutron yield although the early HXR pulse interference requires further confirmation as to whether the subsequent multiple pulses are induced by neutrons. Together, these measurements suggest a neutron-yield upper limit of .
1 March 2023 in AIP Advances
This paper reports some important properties of a dynamic hohlraum radiation source intended to study the high-temperature opacity of medium-Z atoms. The time-resolved axial radiation power in two x-ray diodes gives the time-evolution of an equivalent black-body temperature that peaks at ∼260 eV at stagnation. Time-gated framing pinhole images show that the source comprises an intense high-temperature core that lasts for ∼2 ns preceded by a 10-ns-long lower-temperature implosion phase that emits mostly softer x rays. Combining pinhole images with soft x-ray power gives a time-resolved brightness radiation temperature that reaches 130 eV. Thus, the lower-temperature source could ionize an opacity sample, then the intense high-temperature radiation pulse could measure its opacity. Likewise, the time-integrated spectrum measured with a spherically bent crystal spectrometer is compatible with multiple blackbodies with different temperatures, from 176 to 185 eV. These characterizations suggest that this dynamic hohlraum can be used for high-temperature opacity measurements.
1 November 2023 in Review of Scientific Instruments
Microchannel plate (MCP) photomultiplier tubes (PMTs) are frequently used in experimental diagnostics, where they are operated in single-pulse current measurement mode. However, considering the significant amplitude fluctuations in the measured signal, the resulting output signal from the MCP-PMT is inevitably distorted by gain saturation. Therefore, understanding the correlation between the MCP-PMT output signal and gain saturation is critical in assessing the extent of output signal distortion and determining the MCP-PMT saturation level. This knowledge allows for a more precise assessment of the input signal's features. In this paper, we present an experimental method for restoring the initial waveform from the saturated MCP-PMT signal. To correct the amplitude-drop caused by gain saturation, our technique involves calibrating the MCP-PMT's relative gain as a function of the accumulated output charge using a square-wave light source. We then applied this approach to restore a ∼500 ns saturated pulse from a double-layer 10 mm diameter MCP-PMT. The restored signal showed a deviation of less than 6% from the reference waveform, which validates the effectiveness of the technique.