Keitaro Okamoto

Keitaro Okamoto

Auto-generated profile, based on publicly available information

Keitaro Okamoto

Department of Cardiovascular Surgery, Oita University, Oita, Japan

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Cell Metabolism
Verified
Journal Article
Closed access
CJCholsoon Jang
Cholsoon Jang
SHSheng Hui
Sheng Hui
XZXianfeng Zeng
Xianfeng Zeng
ACAlexis J. Cowan
Alexis J. Cowan
LWLin Wang
Lin Wang
JRJoshua D. Rabinowitz
Joshua D. Rabinowitz

11 January 2022 in EJVES Vascular Forum
Verified
Journal Article
Open access
RHRyuji Higashita
Ryuji Higashita
YNYasuhide Nakayama
Yasuhide Nakayama
YSYasuyuki Shiraishi
Yasuyuki Shiraishi
RIRyosuke Iwai
Ryosuke Iwai
YIYusuke Inoue
Yusuke Inoue
SMSHINJI MIYAMOTO
SHINJI MIYAMOTO
There is a need for small diameter vascular substitutes in the absence of available autologous material. A small diameter, long tissue engineered vascular graft was developed using a completely autologous approach called “in body tissue architecture technology (iBTA)”. The aim of this pilot study was to evaluate “Biotubes”, iBTA induced autologous collagenous tubes, for their potential use as small diameter vascular bypass conduits. Biotubes (internal diameter 4 mm, length 50 cm, wall thickness 0.85 mm) were prepared by subcutaneous embedding of plastic moulds (Biotube Maker) in three goats for approximately two months. Allogenic Biotubes (length 10 cm [n = 2], 15 cm [n = 2], 22 cm [n = 2]) were bypassed to both carotid arteries by end to side anastomosis with their ligation between the anastomoses in another three goats. Residual Biotubes were examined for their mechanical properties. After four weeks, the harvested Biotubes were evaluated histologically. All Biotubes had sufficient pressure resistance, approximately 3000 mmHg. Although wall thickening occurred at two proximal anastomosis sites, all six grafts were patent without luminal thrombus formation, stenosis, or aneurysm deformation throughout the implantation period. Endothelial cells covered both anastomosis sites almost completely, with partial covering in the central portion of the grafts. Furthermore, α smooth muscle actin positive cells infiltrated the middle layer along almost the entire graft length. This preliminary study showed that small diameter, long, tissue engineered Biotubes could function properly as arterial bypass conduits in a large animal for one month without any abnormal change in vascular shape. Thus, small diameter, long Biotubes are potentially viable conduits, which are biocompatible and labour non-intensive, and therefore, suitable for clinical practice. Additionally, Biotubes can start the regeneration process in a short period of time.

1 June 2018 in Journal of Biomechanics
Verified
Journal Article
Closed access
EPEric L. Pierce
Eric L. Pierce
CBCharles H. Bloodworth
Charles H. Bloodworth
AIAkito Imai
Akito Imai
KOKeitaro Okamoto
Keitaro Okamoto
YSYoshiaki Saito
Yoshiaki Saito
AYAjit Yoganathan
Ajit Yoganathan

1 January 2020 in General Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
PDF file
TKTakayuki Kawashima
Takayuki Kawashima
KHKyohei Hatori
Kyohei Hatori
TMTakayuki Mizoguchi
Takayuki Mizoguchi
YOYoshifumi Oda
Yoshifumi Oda
MAMasanagi Arakura
Masanagi Arakura
SMShinji Miyamoto
Shinji Miyamoto

1 May 2020 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
BNBeatrice E. Ncho
Beatrice E. Ncho
EPEric L. Pierce
Eric L. Pierce
CBCharles H. Bloodworth
Charles H. Bloodworth
AIAkito Imai
Akito Imai
KOKeitaro Okamoto
Keitaro Okamoto
AYAjit Yoganathan
Ajit Yoganathan

1 January 2016 in Annals of Vascular Diseases
Verified
Journal Article
Open access
STSatoshi Takebayashi
Satoshi Takebayashi
JHJun Hirota
Jun Hirota
KMKazuki Mori
Kazuki Mori
TSTakashi Shuto
Takashi Shuto
KOKeitaro Okamoto
Keitaro Okamoto
SMShinji Miyamoto
Shinji Miyamoto
Endovascular aortic aneurysm repair (EVAR) has revolutionized the management of abdominal aortic aneurysms (AAAs), with lower perioperative morbidity and mortality compared to conventional surgical repair. However, late secondary re-interventions after EVAR are still needed before aneurysm rupture in many cases. A patient with impending rupture of an AAA associated with a type I endoleak 7 years after EVAR who was successfully treated with a unique technique of fixation of the proximal aortic neck taking into account the structure of the stent graft is reported. This technique offers a safe solution to late open conversion after failed EVAR.