Yusuke Inoue

Advanced Medical Engineering Research Center Asahikawa Medical University Asahikawa Japan

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2007 in IEEE/MTT-S International Microwave Symposium
Verified
Conference Paper
Closed access
YIY. Inoue
Y. Inoue
SMS. Masuda
S. Masuda
MKM. Kanamura
M. Kanamura
TOT. Ohki
T. Ohki
KMK. Makiyama
K. Makiyama
KJK. Joshin
K. Joshin
We analyzed the degradation mode of GaN-HEMTs. We observed the sudden degradation to make serious influence on the reliability. In this paper, we proposed a new approach to eliminate sudden-degradation devices. By measuring the gate leakage current before stress test, we can predict the sudden degradation. We also discussed the gate leakage current factor, for example, the surface hexagonal pits. Using this eliminating method, we could select the reliable devices with a life of over 1 times 106 hours at high-temperature of 200degC.

18 February 2008 in Acta Physiologica
Verified
Journal Article
Closed access
PDF file
IYI. Yokoyama
I. Yokoyama
YIY. Inoue
Y. Inoue
TKT. Kinoshita
T. Kinoshita
HIHIDEKI ITOH
HIDEKI ITOH
IKI. Kanno
I. Kanno
HIHidehiro Iida
Hidehiro Iida

11 January 2022 in EJVES Vascular Forum
Verified
Journal Article
Open access
RHRyuji Higashita
Ryuji Higashita
YNYasuhide Nakayama
Yasuhide Nakayama
YSYasuyuki Shiraishi
Yasuyuki Shiraishi
RIRyosuke Iwai
Ryosuke Iwai
YIYusuke Inoue
Yusuke Inoue
SMSHINJI MIYAMOTO
SHINJI MIYAMOTO
There is a need for small diameter vascular substitutes in the absence of available autologous material. A small diameter, long tissue engineered vascular graft was developed using a completely autologous approach called “in body tissue architecture technology (iBTA)”. The aim of this pilot study was to evaluate “Biotubes”, iBTA induced autologous collagenous tubes, for their potential use as small diameter vascular bypass conduits. Biotubes (internal diameter 4 mm, length 50 cm, wall thickness 0.85 mm) were prepared by subcutaneous embedding of plastic moulds (Biotube Maker) in three goats for approximately two months. Allogenic Biotubes (length 10 cm [n = 2], 15 cm [n = 2], 22 cm [n = 2]) were bypassed to both carotid arteries by end to side anastomosis with their ligation between the anastomoses in another three goats. Residual Biotubes were examined for their mechanical properties. After four weeks, the harvested Biotubes were evaluated histologically. All Biotubes had sufficient pressure resistance, approximately 3000 mmHg. Although wall thickening occurred at two proximal anastomosis sites, all six grafts were patent without luminal thrombus formation, stenosis, or aneurysm deformation throughout the implantation period. Endothelial cells covered both anastomosis sites almost completely, with partial covering in the central portion of the grafts. Furthermore, α smooth muscle actin positive cells infiltrated the middle layer along almost the entire graft length. This preliminary study showed that small diameter, long, tissue engineered Biotubes could function properly as arterial bypass conduits in a large animal for one month without any abnormal change in vascular shape. Thus, small diameter, long Biotubes are potentially viable conduits, which are biocompatible and labour non-intensive, and therefore, suitable for clinical practice. Additionally, Biotubes can start the regeneration process in a short period of time.

1 November 2013
Verified
Conference Paper
Closed access
YIYusuke Inoue
Yusuke Inoue
THTakahiro Hirama
Takahiro Hirama
MWMasayoshi Wada
Masayoshi Wada
In this paper, we study the design of omnidirectional mobile robots with Active-Caster RObotic drive with BAll Transmission (ACROBAT). ACROBAT system has been developed by the authors group which realizes mechanical coordination of wheel and steering motions for creating caster behaviors without computer calculations. A motion in the specific direction relative to a robot body is fully depends on the motion of a specific motor. This feature gives a robot designer to build an omnidirectional mobile robot propelled by active-casters with no redundant actuation with a simple control. A controller of the robot becomes as simple as that for omni-wheeled robotic bases. Namely 3DOF of the omnidirectional robot is controlled by three motors using a simple and constant kinematics. ACROBAT includes a unique dual-ball transmission to transmit traction power to rotate and orient a drive wheel with distributing velocity components to wheel and steering axes in an appropriate ratio. Therefore a sensor for measuring a wheel orientation and calculations for velocity distributions are totally removed from a conventional control system. To build an omnidirectional vehicle by ACROBAT, the significant feature is some multiple drive shafts can be driven by a common motor which realizes non-redundant actuation of the robotic platform. A kinematic model of the proposed robot with ACROBAT is analyzed and a mechanical condition for realizing a non-redundant actuation is derived. Based on the kinematic model and the mechanical condition, computer simulations of the mechanism are performed. A prototype two-wheeled robot with two ACROBATs is designed and built to verify the availability of the proposed system. In the experiments, the prototype robot shows successful omnidirectional motions with a simple and constant kinematics based control.

1 January 2021 in Advanced Biomedical Engineering
Verified
Journal Article
Open access
PDF file
AYAkihiro Yamada
Akihiro Yamada
YIYusuke Inoue
Yusuke Inoue
YSYasuyuki Shiraishi
Yasuyuki Shiraishi
TSTakashi Seki
Takashi Seki
TYTomoyuki Yambe
Tomoyuki Yambe
In traditional Chinese pulse diagnosis, the pulses of bilateral radial arteries are palpated by three fingers. In this study, a device that can objectively perform pulse diagnosis using multiple pressure sensors with a cuff was developed. The device has three pressure sensors in series and a cuff to apply external pressure load. Pulse waves were measured using the non-invasive pulse diagnostic device. The relationship of the data obtained from the proposed system with the diagnosis by the traditional method was examined. The study was conducted with the approval of the Ethics Committee in Tohoku University. Twelve adult male subjects were studied. Data of pulse waveforms recorded from the pulse diagnosis device, electrocardiogram, and continuous blood pressure measured at the fingertip were stored and analyzed. The pulse waves of the subjects were categorized as middle pulse, floating pulse, or sunken pulse according to pulse diagnosis in traditional Chinese medicine. Pulse–waveform data were obtained to measure the pulse–pressure changes, which showed different patterns of the rise time at the three measurement sites. Envelope analysis of the pulse waveform from the middle sensor revealed that the peak value of the pulse pressure increased during calculation stress compared to the resting state. It was possible to measure the pulse waves even when a higher external pressure was applied. Objective pulse-wave measurement using a method similar to that in traditional pulse diagnosis was realized, and pulse waveforms were measured using the proposed pulse diagnosis system.

12 November 2022 in Artificial Organs
Verified
Journal Article
Open access
KHKohei Hatakenaka
Kohei Hatakenaka
WHWataru Hijikata
Wataru Hijikata
TFTatsuki Fujiwara
Tatsuki Fujiwara
KOKatsuhiro Ohuchi
Katsuhiro Ohuchi
YIYusuke Inoue
Yusuke Inoue
Background: Mechanical circulatory support devices, such as left ventricular assist devices, have recently been used in patients with heart failure as destination therapy but the formation of thrombus in blood pumps remains a critical problem. In this study, we propose a mechanical antithrombogenic method by impeller excitation using a magnetically levitated (Maglev) centrifugal pump. Previous studies have shown that one‐directional excitation prevents thrombus; however, it is effective in only one direction. In this study, we aimed to obtain a better effect by vibrating it in a circular orbit to induce uniform changes in the shear‐rate field entirely around the impeller.Methods: The blood coagulation time was compared using porcine blood. (1) The flow rate was set to 1 L/min, and applied excitation was at a frequency of 280 Hz and amplitude of 3 μm. (2) Moreover, the effect was compared by varying the frequency, amplitude, and direction of the excitation. In this experiment, the flow rate was set to 0.3 L/min.Results: (1) The thrombus formation time was 77 min without excitation and 133 min with excitation, which was 1.7 times longer. (2) The results showed no difference between (280 Hz, 3 μm) and (50 Hz, 16 μm) circular orbital excitations, and no directional difference, with thrombus formation of 2.5 times longer under all conditions than that without excitation.Conclusion: In the case of simple reciprocating excitation, the time was approximately 1.2 times longer. This indicated that the circular orbital excitation is more effective.