19 March 2007 in IEEE Transactions on Biomedical Engineering
The conductivity and permittivity of breast tumors are known to differ significantly from those of normal breast tissues, and electrical impedance tomography (EIT) is being studied as a modality for breast cancer imaging to exploit these differences. At present, X-ray mammography is the primary standard imaging modality used for breast cancer screening in clinical practice, so it is desirable to study EIT in the geometry of mammography. This paper presents a forward model of a simplified mammography geometry and a reconstruction algorithm for breast tumor imaging using EIT techniques. The mammography geometry is modeled as a rectangular box with electrode arrays on the top and bottom planes. A forward model for the electrical impedance imaging problem is derived for a homogeneous conductivity distribution and is validated by experiment using a phantom tank. A reconstruction algorithm for breast tumor imaging based on a linearization approach and the proposed forward model is presented. It is found that the proposed reconstruction algorithm performs well in the phantom experiment, and that the locations of a 5-mm-cube metal target and a 6-mm-cube agar target could be recovered at a target depth of 15 mm using a 32 electrode system
1 January 1997 in IEEE Transactions on Biomedical Engineering
Electrical impedance tomography (EIT) uses low-frequency current and voltage measurements made on the boundary of a body to compute the conductivity distribution within the body. Since the permittivity distribution inside the body also contributes significantly to the measured voltages, the present reconstruction algorithm images complex conductivity distributions. A finite element model (FEM) is used to solve the forward problem, using a 6017-node mesh for a piecewise-linear potential distribution. The finite element solution using this mesh is compared with the analytical solution for a homogeneous field and a maximum error of 0.05% is observed in the voltage distribution. The boundary element method (BEM) is also used to generate the voltage data for inhomogeneous conductivity distributions inside regions with noncircular boundaries. An iterative reconstruction algorithm is described for approximating both the conductivity and permittivity distributions from this data. The results for an off-centered inhomogeneity showed a 35% improvement in contrast from that seen with only one iteration, for both the conductivity and the permittivity values. It is also shown that a significant improvement in images results from accurately modeling a noncircular boundary. Both static and difference images are distorted by assuming a circular boundary and the amount of distortion increases significantly as the boundary shape becomes more elliptical. For a homogeneous field in an elliptical body with axis ratio of 0.73, an image reconstructed assuming the boundary to be circular has an artifact at the center of the image with an error of 20%. This error increased to 37% when the axis ratio was 0.64. A reconstruction algorithm which used a mesh with the same axis ratio as the elliptical boundary reduced the error in the conductivity values to within 0.5% of the actual values.
1 January 1996 in IEEE Transactions on Biomedical Engineering
Acute pulmonary edema was assessed quantitatively in 12 experiments on six anesthetized dogs. Thirty-two copper foil electrodes were placed around each animal's thorax at the level of the third intercostal space. A real-time electrical impedance tomograph was used to form images of the electrical admittivity of the thorax in and near the plane of these electrodes. The lungs were identified by studying the change in admittivity associated with inspiration. Mean admittivity in these lung regions was assessed at 40-min intervals for the next 3-6 hours. In six control experiments, each having a duration of 200 min, the initial admittivity of the lung regions was 102 +/- 16(SD) mS/m. Lung admittivity usually increased during the first 80 min, and then remained within 2 mS/m of its value at 80 min for the remaining 120 min. In six experiments with pulmonary edema, an initial period of change followed by stability was observed. When stability had been attained, 0.07 ml/kg of oleic acid was injected slowly into a central venous site. Five animals received oleic acid, the sixth received a sham injection of saline. In the five receiving oleic acid, lung admittivity rose steadily for the remainder of the experiment. The increase in lung admittivity in these five animals was between 4 and 16 mS/m. In the sham injected experiment, the lung admittivity changed by 1 mS/m. We conclude that impedance imaging can provide semiquantitative assessment of the development of acute pulmonary edema.
1 February 2000 in Physiological Measurement
Electrical impedance tomography is a technology for producing images of internal body structures based upon electrical measurements made from electrodes on the body surface. Typically a single plane of electrodes is used, seeking to reconstruct a cross section of the body. Yet the majority of image reconstruction algorithms ignore the three-dimensional (3D) characteristics of the current flow in the body. Actually, a substantial amount of current flows out of the electrode plane, creating distortions in the resulting images. This paper describes a reconstruction algorithm, ToDLeR, for solving a linearized 3D inverse problem in impedance imaging. The algorithm models the body as a homogeneous cylinder and accounts for the 3D current flow in the body by analytically solving for the current flow from one or more layers of electrodes on the surface of the cylinder. The algorithm was implemented on the ACT3 real-time imaging system and data were collected from a 3D test phantom using one, two and four layers of electrodes. By using multiple planes of electrodes, improved accuracy in any particular electrode plane was obtained, with decreased sensitivity to out-of-plane objects. A cylindrical target located vertically more than 8 cm below a single layer of 16 electrodes, and positioned radially midway between the centre and the boundary, produced an image that had 35% of the value obtained when the target was in the electrode plane. By adding an additional layer of 16 electrodes below the first electrode plane, and using 3D current patterns, this artefact was reduced to less than 10% of the peak value. We conclude that the 3D algorithm, used with multiple planes of electrodes, reduces the distortions from out-of-plane structures in the body.
20 June 2008 in IEEE Transactions on Biomedical Engineering
Phantoms are frequently used in medical imaging systems to test hardware, reconstruction algorithms, and the interpretation of data. This report describes and characterizes the use of powdered graphite as a means of adding a significant reactive component or permittivity to useful phantom media for electrical impedance imaging. The phantom materials produced have usable complex admittivity at the electrical impedance tomography (EIT) frequencies from a few kilohertz to 1 MHz, as measured by our EIT system (ACT4) and by a commercial bioimpedance analyzer (BIS 4000, Xitron). We have also studied a commercial ultrasound coupling gel, which is highly electrically conductive and semisolid but that permits objects to move within it. The mixture of agar-graphite and gel-graphite, increases in permittivity and conductivity are proportional to the graphite concentration. We also report the use of a porous polymer membrane to simulate skin. A thin layer of this membrane increased resistance and the characteristic frequency of the phantoms, providing a promising candidate to simulate the effect of skin and the layered structure of a breast or other anatomical structure. The graphite also provides a realistic level of ldquospecklerdquo in ultrasound images of the phantom, which may be useful in developing dual-mode imaging systems with ultrasound and the EIT.
26 June 2007 in Physiological Measurement
Research on freshly-excised malignant breast tissues and surrounding normal tissues in an in vitro impedance cell has shown that breast tumors have different conductivity and permittivity from normal or non-malignant tissues. This contrast may provide a basis for breast cancer detection using electrical impedance imaging. This paper describes a procedure for collecting electrical impedance spectroscopy data simultaneously and in register with tomosynthesis data from patients. We describe the methods used to analyze the data in order to determine if the electrodes are making contact with the breast of the patient. Canonical voltage patterns are applied and used to synthesize the data that would have resulted from constant voltage patterns applied to each of two parallel mammography plates. A type of Cole-Cole plot is generated and displayed from each of the currents measured on each of the electrodes for each of the frequencies (5, 10, 30, 100 and 300 kHz) of applied voltages. We illustrate the potential usefulness of these displays in distinguishing breast cancer from benign lesions with the Cole-Cole plots for two patients--one having cancer and one having a benign lesion--by comparing these graphs with electrical impedance spectra previously found by Jossinet and Schmitt in tissue samples taken from a variety of patients.