Representative Publications

View All Publications
19 March 2007 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MCMyoung Hwan Choi
Myoung Hwan Choi
TKTzu-Jen Kao
Tzu-Jen Kao
DIDavid Isaacson
David Isaacson
GSGary J. Saulnier
Gary J. Saulnier
JNJonathan C. Newell
Jonathan C. Newell
The conductivity and permittivity of breast tumors are known to differ significantly from those of normal breast tissues, and electrical impedance tomography (EIT) is being studied as a modality for breast cancer imaging to exploit these differences. At present, X-ray mammography is the primary standard imaging modality used for breast cancer screening in clinical practice, so it is desirable to study EIT in the geometry of mammography. This paper presents a forward model of a simplified mammography geometry and a reconstruction algorithm for breast tumor imaging using EIT techniques. The mammography geometry is modeled as a rectangular box with electrode arrays on the top and bottom planes. A forward model for the electrical impedance imaging problem is derived for a homogeneous conductivity distribution and is validated by experiment using a phantom tank. A reconstruction algorithm for breast tumor imaging based on a linearization approach and the proposed forward model is presented. It is found that the proposed reconstruction algorithm performs well in the phantom experiment, and that the locations of a 5-mm-cube metal target and a 6-mm-cube agar target could be recovered at a target depth of 15 mm using a 32 electrode system

7 December 2009 in Physical Review E
Verified
Journal Article
Closed access
PDF file
SISamuel A. Isaacson
Samuel A. Isaacson
DIDavid Isaacson
David Isaacson
To model biochemical systems in which both noise in the chemical reaction process and spatial movement of molecules is important, both the reaction-diffusion master equation (RDME) and Smoluchowski diffusion-limited reaction (SDLR) partial differential equation (PDE) models have been used. In previous work we showed that the solution to the RDME may be interpreted as an asymptotic approximation in the reaction radius to the solution of the SDLR PDE [S. A. Isaacson, SIAM J. Appl. Math. 70, 77 (2009)]. The approximation was shown to be divergent in the limit that the lattice spacing in the RDME approached zero. In this work we expand upon these results for the special case of the two-molecule annihilation reaction, A+B→∅. We first introduce a third stochastic reaction-diffusion PDE model that incorporates a pseudopotential based bimolecular reaction mechanism. The solution to the pseudopotential model is then shown to be an asymptotic approximation to the solution of the SDLR PDE for small reaction radii. We next illustrate how the RDME may be obtained by a formal discretization of the pseudopotential model, motivating why the RDME is itself an asymptotic approximation of the SDLR PDE. Finally, we give a more detailed numerical analysis of the difference between solutions to the RDME and SDLR PDE models as a function of both the reaction-radius and the lattice spacing (in the RDME).

1 February 2000 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
RBR S Blue
R S Blue
DID Isaacson
D Isaacson
JNJ C Newell
J C Newell
Electrical impedance tomography is a technology for producing images of internal body structures based upon electrical measurements made from electrodes on the body surface. Typically a single plane of electrodes is used, seeking to reconstruct a cross section of the body. Yet the majority of image reconstruction algorithms ignore the three-dimensional (3D) characteristics of the current flow in the body. Actually, a substantial amount of current flows out of the electrode plane, creating distortions in the resulting images. This paper describes a reconstruction algorithm, ToDLeR, for solving a linearized 3D inverse problem in impedance imaging. The algorithm models the body as a homogeneous cylinder and accounts for the 3D current flow in the body by analytically solving for the current flow from one or more layers of electrodes on the surface of the cylinder. The algorithm was implemented on the ACT3 real-time imaging system and data were collected from a 3D test phantom using one, two and four layers of electrodes. By using multiple planes of electrodes, improved accuracy in any particular electrode plane was obtained, with decreased sensitivity to out-of-plane objects. A cylindrical target located vertically more than 8 cm below a single layer of 16 electrodes, and positioned radially midway between the centre and the boundary, produced an image that had 35% of the value obtained when the target was in the electrode plane. By adding an additional layer of 16 electrodes below the first electrode plane, and using 3D current patterns, this artefact was reduced to less than 10% of the peak value. We conclude that the 3D algorithm, used with multiple planes of electrodes, reduces the distortions from out-of-plane structures in the body.

20 June 2008 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
TKTzu-Jen Kao
Tzu-Jen Kao
GSGary J. Saulnier
Gary J. Saulnier
DIDavid Isaacson
David Isaacson
TSThomas L. Szabo
Thomas L. Szabo
JNJonathan C. Newell
Jonathan C. Newell
Phantoms are frequently used in medical imaging systems to test hardware, reconstruction algorithms, and the interpretation of data. This report describes and characterizes the use of powdered graphite as a means of adding a significant reactive component or permittivity to useful phantom media for electrical impedance imaging. The phantom materials produced have usable complex admittivity at the electrical impedance tomography (EIT) frequencies from a few kilohertz to 1 MHz, as measured by our EIT system (ACT4) and by a commercial bioimpedance analyzer (BIS 4000, Xitron). We have also studied a commercial ultrasound coupling gel, which is highly electrically conductive and semisolid but that permits objects to move within it. The mixture of agar-graphite and gel-graphite, increases in permittivity and conductivity are proportional to the graphite concentration. We also report the use of a porous polymer membrane to simulate skin. A thin layer of this membrane increased resistance and the characteristic frequency of the phantoms, providing a promising candidate to simulate the effect of skin and the layered structure of a breast or other anatomical structure. The graphite also provides a realistic level of ldquospecklerdquo in ultrasound images of the phantom, which may be useful in developing dual-mode imaging systems with ultrasound and the EIT.

1 August 2007
Verified
Conference Paper
Closed access
GSGary J. Saulnier
Gary J. Saulnier
NLNing Liu
Ning Liu
CTChandana Tamma
Chandana Tamma
HXHongjun Xia
Hongjun Xia
TKTzu-Jen Kao
Tzu-Jen Kao
DIDavid Isaacson
David Isaacson
This paper describes Rensselaer's ACT 4 electrical impedance tomography system which has been developed for breast cancer detection. ACT 4 acquires electrical impedance data at a set of discrete frequencies in the range from 3.33 kHz to 1 MHz and can support up to 72 electrodes. The instrument applies either voltages or currents to all the electrodes simultaneously and measures the resulting currents and/or voltages. Radiolucent electrode arrays are applied to the compression plates of an x-ray mammography system for collecting impedance data in register with x-ray images. The analog front-end electronics are supported with a distributed digital system, including a computer, Digital Signal Processors (DSPs) and Field-Programmable Gate Arrays (FPGAs). A Microsoft Visual C/C++ -based user interface controls the system operation. The overall system architecture is presented as well as performance results.

23 May 2008 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
TKTzu-Jen Kao
Tzu-Jen Kao
GBGregory Boverman
Gregory Boverman
BKBong Seok Kim
Bong Seok Kim
DIDavid Isaacson
David Isaacson
GSGary J. Saulnier
Gary J. Saulnier
DKDaniel B Kopans
Daniel B Kopans
It has been known for some time that many tumors have a significantly different conductivity and permittivity from surrounding normal tissue. This high ldquocontrastrdquo in tissue electrical properties, occurring between a few kilohertz and several megahertz, may permit differentiating malignant from benign tissues. Here we show the ability of electrical impedance spectroscopy (EIS) to roughly localize and clearly distinguish cancers from normal tissues and benign lesions. Localization of these lesions is confirmed by simultaneous, in register digital breast tomosynthesis (DBT) mammography or 3-D mammograms.