Keith Winwood

Keith Winwood

Auto-generated profile, based on publicly available information

Keith Winwood

Reader, Department of Life Sciences, Manchester Metropolitan University, Dalton Building, Chester Street, Manchester M1 5GD, UK

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2020 in Annals of Human Biology
Verified
Journal Article
Closed access
JPJames Parr
James Parr
KWKeith Winwood
Keith Winwood
EHEmma Hodson-Tole
Emma Hodson-Tole
Frederik J.A. DeconinckFrederik J.A. Deconinck
Frederik J.A. Deconinck
LPLes Parry
Les Parry
SCSean P. Cumming
Sean P. Cumming
Background: Three commonly used non-invasive protocols are implemented to estimate the timing at which PHV most likely occurs. Accurate estimation of circumpubertal years can aid in managing training load of adolescent athletes. Aim: Three protocols were compared against observed age at PHV: an estimate of 13.8 ± 1.0 years - generic age at PHV (from longitudinal measures); an estimate based on the maturity offset equation, predicted age at PHV ±1.0 year; a window of PHV based on 85 – 96% of predicted adult height at time of observation. Subjects and methods: A final sample of 23 (from 28) adolescent participants who were selected from the academy of an English Premier League club. Anthropometric measures were collected across five playing seasons; age at PHV was estimated with Super-Imposition by Translation and Rotation (SITAR). The three protocols were compared based on measures at 13.0 years. Results and Conclusions: An age window based on predicted maturity offset did not improve estimation of PHV compared to generic age method; however, the percentage of predicted adult height window showed improvement in performance shown by the following results. Predicted age at PHV correctly assigned 15 participants (65%) as experiencing PHV, while the percentage height correctly assigned 17 participants (74%). Generic age and predicted age at PHV correctly predicted observed age at PHV for 14 participants (61%), percentage of adult height window correctly predicted 22 participants (96%).

1 August 2020 in Journal of Sports Medicine
Verified
Journal Article
Open access
PDF file
JPJames Parr
James Parr
KWKeith Winwood
Keith Winwood
EHEmma Hodson-Tole
Emma Hodson-Tole
Frederik J.A. DeconinckFrederik J.A. Deconinck
Frederik J.A. Deconinck
JHJames P. Hill
James P. Hill
SCSean P. Cumming
Sean P. Cumming
The main and interactive effect of biological maturity and relative age upon physical performance in adolescent male soccer players was considered. Consistent with previous research, it was hypothesised that participants of greater maturity or born earlier in the selection year would perform better in terms of physical performance tests. This cross-sectional study consisted of 84 male participants aged between 11.3 and 16.2 years from a professional soccer academy in the English Premier League. Date of birth, height, weight, and parental height were collected. Sprint, change of direction, countermovement jump, and reactive strength index were considered for physical performance. Relative age was based on the birth quarter for the selection year. Maturity status was based upon the percentage of predicted adult height attained. Linear regression models highlighted that maturation was associated with performance on all but one of the physical performance tests, the reactive strength index. In contrast, relative age only served as a significant predictor of performance on the countermovement jump. This study indicated that physical performance (in the tests studied) seems to be related to the biological maturity status of a player but not their relative age. This finding is important because it suggests that early-maturing players perform better in the majority of physical performance tests, and the commonly held belief that relative age effect influences performance may be overstated.

2 March 2023 in Sports Engineering
Verified
Journal Article
Open access
PDF file
SISyed Adil Imam
Syed Adil Imam
AHAngus C. Hughes
Angus C. Hughes
Matt CarreMatt Carre
Matt Carre
HDHeather Driscoll
Heather Driscoll
KWKeith Winwood
Keith Winwood
Tom AllenTom Allen
Tom Allen
A finite element model of an impact test on a soft tissue simulant, used as part of a shoulder surrogate, was developed in Ansys© LS-DYNA®. The surrogate consisted of a metal hemicylindrical core, with a diameter of 75 mm, covered with a 15 mm thick relaxed muscle simulant. The muscle simulant consisted of a 14 mm thick layer of silicone covered with 1 mm thick chamois leather to represent skin. The material properties of the silicone were obtained via quasi-static compression testing (curve fit with hyperelastic models) and compressive stress relaxation testing (curve fit with a Prony series). Outputs of the finite element models were compared against experimental data from impact tests on the shoulder surrogate at energies of 4.9, 9.8 and 14.7 J. The accuracy of the finite element models was assessed using four parameters: peak impact force, maximum deformation, impact duration and impulse. A 5-parameter Mooney-Rivlin material model combined with a 2-term Prony series was found to be suitable for modelling the soft tissue simulant of the shoulder surrogate. This model had under 10% overall mean deviation from the experimental values for the four assessment parameters across the three impact energies. Overall, the model provided a repeatable test method that can be adapted to help predict injuries to skin tissue and the performance/efficacy of personal protective equipment.

21 August 2023 in Annals of 3D Printed Medicine
Verified
Journal Article
Open access
GLGemma Leslie
Gemma Leslie
KWKeith Winwood
Keith Winwood
ASAndy Sanderson
Andy Sanderson
PZPeter Zioupos
Peter Zioupos
Tom AllenTom Allen
Tom Allen

27 April 2023 in JSAMS Plus
Verified
Journal Article
Open access
GLGemma E. Leslie
Gemma E. Leslie
KWKeith Winwood
Keith Winwood
WWWeizhuo Wang
Weizhuo Wang
NHNick Hamilton
Nick Hamilton
Tom AllenTom Allen
Tom Allen
To investigate the effect on the impact response of wrist protectors by incorporating a soft tissue simulant on to a wrist surrogate made of stiff material. The effect of protector strapping condition was also investigated. A compliant and a stiff surrogate were made, based on the wrist geometry specified in ISO 20320:2020 for the “Limitation of wrist extension” test. Two styles of wrist protectors (short, long) were tested on each limb surrogate, subject to a ∼31 J impact. Six protectors of each style were tested, with two of each at each strapping condition (loose, moderate, tight) on each surrogate (stiff, compliant) (24 combinations). Example temporal force and wrist angle and force vs. wrist angle plots are presented for comparison between conditions. When protectors were on the compliant surrogate, peak impact force was 55–68% lower (short 3.1 vs. 6.8 kN, long 2.7 vs. 8.3 kN). The time to reach this peak force was ∼4 ms (12%) longer, than for the stiff surrogate. Protector strapping condition had no clear effect for the stiff surrogate, with the wrist extending to its limit for all tests. Strapping protectors tighter on the compliant surrogate tended to decrease the maximum wrist angle and peak force. With results being sensitive to surrogate design and strapping condition, these both need to be clearly reported in future work impact testing wrist protectors, with implications for certification tests within standards.

30 May 2025 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
SCSe Hun Chung
Se Hun Chung
KCKathryn Chamberlain
Kathryn Chamberlain
KWKeith Winwood
Keith Winwood
TCTrevor J. Coward
Trevor J. Coward
The lifespan of maxillofacial silicone elastomer-based prostheses can be as short as 6 months, primarily because of sunlight-induced color degradation. Efforts to enhance color stability have led to incorporating additives that include nanoparticles, opacifiers, and ultraviolet (UV) blockers. However, variability in testing methods and the absence of standardized protocols have led to inconsistent findings, underscoring the need for uniform testing to evaluate the color stability of these materials effectively. The purpose of this systematic review and meta-analysis was to assess the methodologies used in maxillofacial color longevity research and to synthesize findings on the effectiveness of additives in enhancing the color stability of pigmented silicone formulations exposed to solar radiation. This systematic review, adhering to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, evaluated the impact of additives on color stability under solar radiation. Searches across PubMed, Web of Science, Embase, Scopus, and Cochrane databases (up to October 2024) followed the Population, Intervention, Comparator, Outcomes (PICO) criteria, limited to English-language studies. Articles were evaluated using a modified Consolidated Standards of Reporting Trials (CONSORT) guideline and quality-assessed with the Newcastle-Ottawa Scale, with high-quality studies (scoring 6 to 9) eligible for meta-analysis. A random-effects model in the RevMan Web tool was used, with heterogeneity assessed via the I² test and results presented in forest plots with 95% confidence intervals. A lack of standardized protocols persists in methodologies concerning specimen dimensions and pigmentation formulations, despite established weathering methods for both outdoor and artificial conditions. The meta-analysis demonstrated consistent improvements in color stability with additives under artificial weathering (P<.001), while no significant improvement was observed during a 3-month period of outdoor weathering (P=.120). High heterogeneity across studies was observed, largely associated with variability in silicone pigmentation formulations. Additives including nanoparticles, opacifiers, and UV blockers enhance the color stability of maxillofacial prostheses; however, the inherent stability of pigments remains a critical factor. Future research should focus on developing standardized testing methods tailored to maxillofacial applications, ensuring representativeness for prostheses and accounting for silicone formulation parameters relative to UV penetration.