Sridhar Ramamurthy

Sridhar Ramamurthy

Auto-generated profile, based on publicly available information

Sridhar Ramamurthy

Surface Science Western Western University London Ontario Canada

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Electrochimica Acta
Verified
Journal Article
Open access
TSThalia Standish
Thalia Standish
JCJian Chen
Jian Chen
RJRebecca Jacklin
Rebecca Jacklin
PJPellumb Jakupi
Pellumb Jakupi
SRSridhar Ramamurthy
Sridhar Ramamurthy
DSDavid Shoesmith
David Shoesmith
The corrosion of high level nuclear waste containers under permanent disposal conditions can occur via a number of processes which change in importance as the environment within a deep geologic repository evolves from oxic to anoxic. The container design involves a copper coating on a steel vessel. The characteristics of these coatings are being assessed using standard analytical methods, including microscopy and electron backscatter diffraction. The corrosion processes on the surface of the coatings and at through-coating defects are also being investigated electrochemically. Although minor differences exist, the surface corrosion of cold sprayed and electrodeposited coatings generally exhibited similar corrosion behaviour to standard wrought copper. Corrosion at the base of a simulated through-coating defect in a cold-sprayed coating was found to proceed via galvanic coupling to oxygen reduction on the coating surface. Besides accumulating damage at the base of the defect, corrosion propagated along the copper/steel interface, most likely a consequence of the damage inflicted during the deposition process

1 August 2018 in Corrosion Science
Verified
Journal Article
Closed access
BIB. Ibrahim
B. Ibrahim
DZD. Zagidulin
D. Zagidulin
MBMehran Behazin
Mehran Behazin
SRS. Ramamurthy
S. Ramamurthy
JWJ.C. Wren
J.C. Wren
DSD.W. Shoesmith
D.W. Shoesmith

12 July 2015 in Corrosion
Verified
Journal Article
Closed access
RPRaheleh Partovi-Nia
Raheleh Partovi-Nia
SRSridhar Ramamurthy
Sridhar Ramamurthy
DZDmitrij Zagidulin
Dmitrij Zagidulin
JCJian Chen
Jian Chen
RJRebecca Jacklin
Rebecca Jacklin
DSDavid W. Shoesmith
David W. Shoesmith
The corrosion behavior of copper cold spray coatings on a carbon steel substrate was compared to that of commercially available wrought copper under the conditions anticipated in a nuclear waste repository. Corrosion potential and linear polarization resistance measurements were conducted over 90 d to 120 d in 3.0 mol/L NaCl under anoxic (1) and oxygenated-to-anoxic (2) conditions to simulate the long (1) and short (2) term redox conditions expected in a Canadian repository. Scanning electron microscopy and x-ray diffractometry were used to observe the morphology of the corroded surface and to identify the corrosion products formed. The two specimens behaved very similarly under both sets of conditions. Negligible corrosion was observed under anoxic conditions and the formation of both Cu+1 (Cu2O) and Cu+2 (Cu2(OH)3Cl) phases occurred under oxygenated conditions. No evidence was observed to suggest the particle boundaries in the cold sprayed coating were preferential corrosion sites.

26 September 2018 in Geosciences
Verified
Journal Article
Open access
PDF file
TSThalia Standish
Thalia Standish
DZDmitrij Zagidulin
Dmitrij Zagidulin
SRSridhar Ramamurthy
Sridhar Ramamurthy
PKPeter G. Keech
Peter G. Keech
DSDavid W. Shoesmith
David W. Shoesmith
JNJames J. Noël
James J. Noël
Within the multi-barrier system proposed for the permanent disposal of used nuclear fuel, the primary engineered barrier is the sealed metallic container. The present Canadian container design utilizes a carbon steel vessel coated with Cu for corrosion protection. In the event of a defect in the Cu coating that exposes the steel substrate, galvanically accelerated corrosion of steel is, in principle, possible. In this work, the progression of corrosion at a simulated through-coating defect in 3.0 mol/L NaCl solution containing dissolved O2 was monitored using electrochemical measurements and imaged non-destructively using synchrotron X-ray micro computed tomography (micro-CT). The damage volume at the base of the simulated defect was measured from the 3D micro-CT data and used to calculate the amount of O2 used to drive steel corrosion. The results demonstrate that the availability of O2 determines the rate and overall extent of corrosion, while the coatings produced using different deposition and treatment methods (cold spray deposition, heat-treated cold spray deposition, electrodeposition) lead to different corrosion propagation geometries, with the distribution of damage depending on the quality of the Cu/steel interface.

19 June 2025 in Corrosion Science
Verified
Journal Article
Open access
SSSebastian A. Skaanvik
Sebastian A. Skaanvik
Xuejie LiXuejie Li
Xuejie Li
JWJessica E.M. Winslade
Jessica E.M. Winslade
HNHeng-Yong Nie
Heng-Yong Nie
JHJonas Hedberg
Jonas Hedberg
JNJames J. Noël
James J. Noël

15 May 2024 in ChemRxiv
Verified
Preprint
Open access
PDF file
Xuejie LiXuejie Li
Xuejie Li
FFFraser Filice
Fraser Filice
JHJeffrey Daniel Henderson
Jeffrey Daniel Henderson
MBMehran Behazin
Mehran Behazin
SRSridhar Ramamurthy
Sridhar Ramamurthy
JNJames J. Noël
James J. Noël
The mechanism of particle-particle interface (PPI) corrosion observed in cold sprayed (CS) Cu immersed in dilute HNO3 has been elucidated. PPI corrosion is initiated by the oxide inclusions present along the PPIs. The accelerated corrosion rate at PPIs results from the combined effects of confined geometry and catalytic reactions, which involve the electrochemical dissolution of Cu and reduction of NO3−. Annealing the CS Cu at 600°C coalesces the oxide inclusions, thereby breaking the interconnected oxide inclusion network. As a result, the propagation of PPI corrosion is impeded.