Malte Ellerbrock

Malte Ellerbrock

Auto-generated profile, based on publicly available information

Malte Ellerbrock

Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2023 in Radiotherapy and Oncology
Verified
Journal Article
Open access
NPNils Peters
Nils Peters
VTVicki Trier Taasti
Vicki Trier Taasti
BABenjamin Ackermann
Benjamin Ackermann
ABAlessandra Bolsi
Alessandra Bolsi
CDChristina Vallhagen Dahlgren
Christina Vallhagen Dahlgren
PWPatrick Wohlfahrt
Patrick Wohlfahrt
Studies have shown large variations in stopping-power ratio (SPR) prediction from computed tomography (CT) across European proton centres. To standardise this process, a step-by-step guide on specifying a Hounsfield look-up table (HLUT) is presented here. The HLUT specification process is divided into six steps: Phantom setup, CT acquisition, CT number extraction, SPR determination, HLUT specification, and HLUT validation. Appropriate CT phantoms have a head- and body-sized part, with tissue-equivalent inserts in regard to X-ray and proton interactions. CT numbers are extracted from a region-of-interest covering the inner 70% of each insert in-plane and several axial CT slices in scan direction. For optimal HLUT specification, the SPR of phantom inserts is measured in a proton beam and the SPR of tabulated human tissues is computed stoichiometrically at 100 MeV. Including both phantom inserts and tabulated human tissues increases HLUT stability. Piecewise linear regressions are performed between CT numbers and SPRs for four tissue groups (lung, adipose, soft tissue, and bone) and then connected with straight lines. Finally, a thorough but simple validation is performed. The best practices and individual challenges are explained comprehensively for each step. A well-defined strategy for specifying the connection points between the individual line segments of the HLUT is presented. The guide was tested exemplarily on three CT scanners from different vendors, proving its feasibility. The presented step-by-step guide for CT-based HLUT specification with recommendations and examples can contribute to reduce inter-centre variations in SPR prediction.

1 October 2021 in Radiotherapy and Oncology
Verified
Journal Article
Open access
NPNils Peters
Nils Peters
PWPatrick Wohlfahrt
Patrick Wohlfahrt
CDChristina V. Dahlgren
Christina V. Dahlgren
LMLudovic De Marzi
Ludovic De Marzi
MEMalte Ellerbrock
Malte Ellerbrock
CRChristian Richter
Christian Richter
Experimental assessment of inter-centre variation and absolute accuracy of stopping-power-ratio (SPR) prediction within 17 particle therapy centres of the European Particle Therapy Network. A head and body phantom with seventeen tissue-equivalent materials were scanned consecutively at the participating centres using their individual clinical CT scan protocol and translated into SPR with their in-house CT-number-to-SPR conversion. Inter-centre variation and absolute accuracy in SPR prediction were quantified for three tissue groups: lung, soft tissues and bones. The integral effect on range prediction for typical clinical beams traversing different tissues was determined for representative beam paths for the treatment of primary brain tumours as well as lung and prostate cancer. An inter-centre variation in SPR prediction (2σ) of 8.7%, 6.3% and 1.5% relative to water was determined for bone, lung and soft-tissue surrogates in the head setup, respectively. Slightly smaller variations were observed in the body phantom (6.2%, 3.1%, 1.3%). This translated into inter-centre variation of integral range prediction (2σ) of 2.9%, 2.6% and 1.3% for typical beam paths of prostate-, lung- and primary brain-tumour treatments, respectively. The absolute error in range exceeded 2% in every fourth participating centre. The consideration of beam hardening and the execution of an independent HLUT validation had a positive effect, on average. The large inter-centre variations in SPR and range prediction justify the currently clinically used margins accounting for range uncertainty, which are of the same magnitude as the inter-centre variation. This study underlines the necessity of higher standardisation in CT-number-to-SPR conversion.

1 November 2001 in Physics Letters B
Verified
Journal Article
Open access
CAC. Adloff
C. Adloff
VAV. Andreev
V. Andreev
BAB. Andrieu
B. Andrieu
TAT. Anthonis
T. Anthonis
VAV. Arkadov
V. Arkadov
MNM. Zur Nedden
M. Zur Nedden
A measurement is presented of the cross section for D ∗± meson production in diffractive deep-inelastic scattering for the first time at HERA. The cross section is given for the process ep → eXY , where the system X contains at least one D ∗± meson and is separated by a large rapidity gap from a low mass proton remnant system Y . The cross section is presented in the diffractive deep-inelastic region defined by 2< Q 2 2 GeV and |η D ∗ |<1.5 . The cross section is found to be 246±54±56 pb and forms about 6% of the corresponding inclusive D ∗± cross section. The cross section is presented as a function of various kinematic variables, including z P obs which is an estimate of the fraction of the momentum of the diffractive exchange carried by the parton entering the hard-subprocess. The data show a large component of the cross section at low z P obs where the contribution of the boson–gluon-fusion process is expected to dominate. The data are compared with several QCD-based calculations

18 October 2002 in Physics Letters B
Verified
Journal Article
Open access
CAC. Adloff
C. Adloff
VAV. Andreev
V. Andreev
BAB. Andrieu
B. Andrieu
TAT. Anthonis
T. Anthonis
AAA. Astvatsatourov
A. Astvatsatourov
MNM. Zur Nedden
M. Zur Nedden
A search for excited electron (e∗) production is described in which the electroweak decays e∗→eγ, e∗→eZ and e∗→νW are considered. The data used correspond to an integrated luminosity of 120 pb−1 taken in e±p collisions from 1994 to 2000 with the H1 detector at HERA at centre-of-mass energies of 300 and 318 GeV. No evidence for a signal is found. Mass dependent exclusion limits are derived for the ratio of the couplings to the compositeness scale, f/Λ. These limits extend the excluded region to higher masses than has been possible in previous direct searches for excited electrons.

1 November 2021 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Open access
TTThomas Tessonnier
Thomas Tessonnier
SMS. Mein
S. Mein
JBJ. Besuglow
J. Besuglow
BKB. Kopp
B. Kopp
SES. Ecker
S. Ecker
AMA. Mairani
A. Mairani