Stewart Mein

Stewart Mein

Auto-generated profile, based on publicly available information

Stewart Mein

National Institutes for Quantum Science and Technology, 4 Chome-9-1 Anagawa, Inage Ward, Chiba, 263-0024, Chiba, Chiba, 263-8555, JAPAN

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2019 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
SMStewart Mein
Stewart Mein
IDIvana Dokic
Ivana Dokic
CKCarmen Klein
Carmen Klein
TTThomas Tessonnier
Thomas Tessonnier
TBTill Tobias Böhlen
Till Tobias Böhlen
AMAndrea Mairani
Andrea Mairani
Helium (4He) ion beam therapy provides favorable biophysical characteristics compared to currently administered particle therapies, i.e., reduced lateral scattering and enhanced biological damage to deep-seated tumors like heavier ions, while simultaneously lessened particle fragmentation in distal healthy tissues as observed with lighter protons. Despite these biophysical advantages, raster-scanning 4He ion therapy remains poorly explored e.g., clinical translational is hampered by the lack of reliable and robust estimation of physical and radiobiological uncertainties. Therefore, prior to the upcoming 4He ion therapy program at the Heidelberg Ion-beam Therapy Center (HIT), we aimed to characterize the biophysical phenomena of 4He ion beams and various aspects of the associated models for clinical integration. Characterization of biological effect for 4He ion beams was performed in both homogenous and patient-like treatment scenarios using innovative models for estimation of relative biological effectiveness (RBE) in silico and their experimental validation using clonogenic cell survival as the gold-standard surrogate. Towards translation of RBE models in patients, the first GPU-based treatment planning system (non-commercial) for raster-scanning 4He ion beams was devised in-house (FRoG). Our data indicate clinically relevant uncertainty of ±5–10% across different model simulations, highlighting their distinct biological and computational methodologies. The in vitro surrogate for highly radio-resistant tissues presented large RBE variability and uncertainty within the clinical dose range. Existing phenomenological and mechanistic/biophysical models were successfully integrated and validated in both Monte Carlo and GPU-accelerated analytical platforms against in vitro experiments, and tested using pristine peaks and clinical fields in highly radio-resistant tissues where models exhibit the greatest RBE uncertainty. Together, these efforts mark an important step towards clinical translation of raster-scanning 4He ion beam therapy to the clinic.

23 October 2018 in Cancers
Verified
Journal Article
Open access
PDF file
KCKyungdon Choi
Kyungdon Choi
SMStewart B Mein
Stewart B Mein
BKBenedikt Kopp
Benedikt Kopp
Giuseppe MagroGiuseppe Magro
Giuseppe Magro
SMSilvia Molinelli
Silvia Molinelli
AMAndrea Mairani
Andrea Mairani
A fast and accurate dose calculation engine for hadrontherapy is critical for both routine clinical and advanced research applications. FRoG is a graphics processing unit (GPU)-based forward calculation tool developed at CNAO (Centro Nazionale di Adroterapia Oncologica) and at HIT (Heidelberg Ion Beam Therapy Center) for fast and accurate calculation of both physical and biological dose. FRoG calculation engine adopts a triple Gaussian parameterization for the description of the lateral dose distribution. FRoG provides dose, dose-averaged linear energy transfer, and biological dose-maps, -profiles, and -volume-histograms. For the benchmark of the FRoG calculation engine, using the clinical settings available at CNAO, spread-out Bragg peaks (SOBPs) and patient cases for both proton and carbon ion beams have been calculated and compared against FLUKA Monte Carlo (MC) predictions. In addition, FRoG patient-specific quality assurance (QA) has been performed for twenty-five proton and carbon ion fields. As a result, for protons, biological dose values, using a relative biological effectiveness (RBE) of 1.1, agree on average with MC within ~1% for both SOBPs and patient plans. For carbon ions, RBE-weighted dose (DRBE) agreement against FLUKA is within ~2.5% for the studied SOBPs and patient plans. Both MKM (Microdosimetric Kinetic Model) and LEM (Local Effect Model) DRBE are implemented and tested in FRoG to support the NIRS (National Institute of Radiological Sciences)-based to LEM-based biological dose conversion. FRoG matched the measured QA dosimetric data within ~2.0% for both particle species. The typical calculation times for patients ranged from roughly 1 to 4 min for proton beams and 3 to 6 min for carbon ions on a NVIDIA® GeForce® GTX 1080 Ti. This works demonstrates FRoG’s potential to bolster clinical activity with proton and carbon ion beams at CNAO.

3 November 2021 in Frontiers in Physics
Verified
Journal Article
Open access
PLPeter Lysakovski
Peter Lysakovski
AFAlfredo Ferrari
Alfredo Ferrari
TTThomas Tessonnier
Thomas Tessonnier
JBJudith Besuglow
Judith Besuglow
BKBenedikt Kopp
Benedikt Kopp
AMAndrea Mairani
Andrea Mairani
Dose calculation algorithms based on Monte Carlo (MC) simulations play a crucial role in radiotherapy. Here, the development and benchmarking of a novel MC dose engine, MonteRay, is presented for proton therapy aiming to support clinical activity at the Heidelberg Ion Beam Therapy center (HIT) and the development of MRI (magnetic resonance imaging)-guided particle therapy. Comparisons against dosimetric data and gold standard MC FLUKA calculations at different levels of complexity, ranging from single pencil beams in water to patient plans, showed high levels of agreement, validating the physical approach implemented in the dose engine. Additionally, MonteRay has been found to match satisfactorily to FLUKA dose predictions in magnetic fields both in homogeneous and heterogeneous scenarios advocating its use for future MRI-guided proton therapy applications. Benchmarked on 150 MeV protons transported on a 2 × 2 × 2 mm3 grid, MonteRay achieved a high computational throughput and was able to simulate the histories of more than 30,000 primary protons per second on a single CPU core.

29 April 2022 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
PDF file
SMStewart Mein
Stewart Mein
TTThomas Tessonnier
Thomas Tessonnier
BKBenedikt Kopp
Benedikt Kopp
CSChristian Schömers
Christian Schömers
Semi B HarrabiSemi B Harrabi
Semi B Harrabi
AMAndrea Mairani
Andrea Mairani

Verified
Journal Article
Open access
PDF file
HLHans Liew
Hans Liew
SMStewart Mein
Stewart Mein
JDJürgen Debus
Jürgen Debus
IDIvana Dokic
Ivana Dokic
AMAndrea Mairani
Andrea Mairani
The demand for personalized medicine in radiotherapy has been met by a surge of mechanistic models offering predictions of the biological effect of ionizing radiation under consideration of a growing number of parameters. We present an extension of our existing model of cell survival after photon irradiation to explicitly differentiate between the damage inflicted by the direct and indirect (radicals-mediated) action of ionizing radiation. Within our approach, we assume that the oxygenation status affects the indirect action. The effect of different concentrations of dimethyl sulfoxide (DMSO), an effective radical scavenger, has been simulated at different dose levels in normoxic and hypoxic conditions for various cell lines. Our model is found to accurately predict experimental data available in literature, validating the assumptions made in our approach. The presented extension adds further flexibility to our model and could act as basis for further developments of our model.

Verified
Journal Article
Open access
PDF file
HLHans Liew
Hans Liew
SMStewart Mein
Stewart Mein
TTThomas Tessonnier
Thomas Tessonnier
AAAmir Abdollahi
Amir Abdollahi
JDJürgen Debus
Jürgen Debus
AMAndrea Mairani
Andrea Mairani
The impact of the exact temporal pulse structure on the potential cell and tissue sparing of ultra-high dose-rate irradiation applied in FLASH studies has gained increasing attention. A previous version of our biophysical mechanistic model (UNIVERSE: UNIfied and VERSatile bio response Engine), based on the oxygen depletion hypothesis, has been extended in this work by considering oxygen-dependent damage fixation dynamics on the sub-milliseconds scale and introducing an explicit implementation of the temporal pulse structure. The model successfully reproduces in vitro experimental data on the fast kinetics of the oxygen effect in irradiated mammalian cells. The implemented changes result in a reduction in the assumed amount of oxygen depletion. Furthermore, its increase towards conventional dose-rates is parameterized based on experimental data from the literature. A recalculation of previous benchmarks shows that the model retains its predictive power, while the assumed amount of depleted oxygen approaches measured values. The updated UNIVERSE could be used to investigate the impact of different combinations of pulse structure parameters (e.g., dose per pulse, pulse frequency, number of pulses, etc.), thereby aiding the optimization of potential clinical application and the development of suitable accelerators.