Lin-Mei Zhao

Lin-Mei Zhao

Auto-generated profile, based on publicly available information

Lin-Mei Zhao

Department of Radiology, University of Colorado School of Medicine, Aurora, CO, USA; Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
LZLin-Mei Zhao
Lin-Mei Zhao
HZHelen Zhang Zhang
Helen Zhang Zhang
DKDaniel D Kim
Daniel D Kim
KGKanchan Ghimire
Kanchan Ghimire
RHRong Hu
Rong Hu
XFXue Feng
Xue Feng
Objective. Radiation therapy for head and neck (H&N) cancer relies on accurate segmentation of the primary tumor. A robust, accurate, and automated gross tumor volume segmentation method is warranted for H&N cancer therapeutic management. The purpose of this study is to develop a novel deep learning segmentation model for H&N cancer based on independent and combined CT and FDG-PET modalities. Approach. In this study, we developed a robust deep learning-based model leveraging information from both CT and PET. We implemented a 3D U-Net architecture with 5 levels of encoding and decoding, computing model loss through deep supervision. We used a channel dropout technique to emulate different combinations of input modalities. This technique prevents potential performance issues when only one modality is available, increasing model robustness. We implemented ensemble modeling by combining two types of convolutions with differing receptive fields, conventional and dilated, to improve capture of both fine details and global information. Main Results. Our proposed methods yielded promising results, with a Dice similarity coefficient (DSC) of 0.802 when deployed on combined CT and PET, DSC of 0.610 when deployed on CT, and DSC of 0.750 when deployed on PET. Significance. Application of a channel dropout method allowed for a single model to achieve high performance when deployed on either single modality images (CT or PET) or combined modality images (CT and PET). The presented segmentation techniques are clinically relevant to applications where images from a certain modality might not always be available.

12 June 2024 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
OLOwen Leary
Owen Leary
ZZZhusi Zhong
Zhusi Zhong
LBLulu Bi
Lulu Bi
ZJZhicheng Jiao
Zhicheng Jiao
YDYu-Wei Dai
Yu-Wei Dai
JBJerrold Boxerman
Jerrold Boxerman
BACKGROUND AND PURPOSE: Symptoms of normal pressure hydrocephalus (NPH) are sometimes refractory to shunt placement, with limited ability to predict improvement for individual patients. We evaluated an MRI-based artificial intelligence method to predict post-shunt NPH symptom improvement. MATERIALS AND METHODS: NPH patients who underwent magnetic resonance imaging (MRI) prior to shunt placement at a single center (2014–2021) were identified. Twelve-month post-shunt improvement in modified Rankin Scale (mRS), incontinence, gait, and cognition were retrospectively abstracted from clinical documentation. 3D deep residual neural networks were built on skull stripped T2-weighted and fluid attenuated inversion recovery (FLAIR) images. Predictions based on both sequences were fused by additional network layers. Patients from 2014–2019 were used for parameter optimization, while those from 2020–2021 were used for testing. Models were validated on an external validation dataset from a second institution (n=33). RESULTS: Of 249 patients, n=201 and n=185 were included in the T2-based and FLAIR-based models according to imaging availability. The combination of T2-weighted and FLAIR sequences offered the best performance in mRS and gait improvement predictions relative to models trained on imaging acquired using only one sequence, with AUROC values of 0.7395 [0.5765–0.9024] for mRS and 0.8816 [0.8030–0.9602] for gait. For urinary incontinence and cognition, combined model performances on predicting outcomes were similar to FLAIR-only performance, with AUROC values of 0.7874 [0.6845–0.8903] and 0.7230 [0.5600–0.8859]. CONCLUSIONS: Application of a combined algorithm using both T2-weighted and FLAIR sequences offered the best image-based prediction of post-shunt symptom improvement, particularly for gait and overall function in terms of mRS. ABBREVIATIONS: NPH = normal pressure hydrocephalus; iNPH = idiopathic NPH; sNPH = secondary NPH; AI = artificial intelligence; ML = machine learning; CSF = cerebrospinal fluid; AUROC = area under the receiver operating characteristic; FLAIR = fluid attenuated inversion recovery; BMI = body mass index; CCI = Charlson Comorbidity Index; SD = standard deviation; IQR = interquartile range

5 November 2025 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
LZLinmei Zhao
Linmei Zhao
MIMaliha R. Imami
Maliha R. Imami
YWYuli Wang
Yuli Wang
YMYitao Mao
Yitao Mao
WHWen-Chi Hsu
Wen-Chi Hsu
HBHarrison X Bai
Harrison X Bai

22 May 2024 in Heliyon
Verified
Journal Article
Open access
LZLin-Mei Zhao
Lin-Mei Zhao
ALAndrew C. Lancaster
Andrew C. Lancaster
RPRitesh Patel
Ritesh Patel
HZHelen Zhang
Helen Zhang
TDTim Q. Duong
Tim Q. Duong
HBHarrison X. Bai
Harrison X. Bai
The purpose of this study is to identify clinical and imaging characteristics associated with post-COVID pulmonary function decline. This study included 22 patients recovering from COVID-19 who underwent serial spirometry pulmonary function testing (PFT) before and after diagnosis. Patients were divided into two cohorts by difference between baseline and post-COVID follow-up PFT: Decline group (>10 % decrease in FEV1), and Stable group (≤10 % decrease or improvement in FEV1). Demographic, clinical, and laboratory data were collected, as well as PFT and chest computed tomography (CT) at the time of COVID diagnosis and follow-up. CTs were semi-quantitatively scored on a five-point severity scale for disease extent in each lobe by two radiologists. Mann-Whitney U-tests, T-tests, and Chi-Squared tests were used for comparison. P-values <0.05 were considered statistically significant. The Decline group had a higher proportion of neutrophils (79.47 ± 4.83 % vs. 65.45 ± 10.22 %; p = 0.003), a higher absolute neutrophil count (5.73 ± 2.68 × 109/L vs. 3.43 ± 1.74 × 109/L; p = 0.031), and a lower proportion of lymphocytes (9.90 ± 4.20 % vs. 21.21 ± 10.97 %; p = 0.018) compared to the Stable group. The Decline group also had significantly higher involvement of ground-glass opacities (GGO) on follow-up chest CT [8.50 (4.50, 14.50) vs. 3.0 (1.50, 9.50); p = 0.032] and significantly higher extent of reticulations on chest CT at time of COVID diagnosis [6.50 (4.00, 9.00) vs. 2.00 (0.00, 6.00); p = 0.039] and follow-up [5.00 (3.00, 13.00) vs. 2.00 (0.00, 5.00); p = 0.041]. ICU admission was higher in the Decline group than in the Stable group (71.4 % vs. 13.3 %; p = 0.014). This study provides novel insight into factors influencing post-COVID lung function, irrespective of pre-existing pulmonary conditions. Our findings underscore the significance of neutrophil counts, reduced lymphocyte counts, pulmonary reticulation on chest CT at diagnosis, and extent of GGOs on follow-up chest CT as potential indicators of decreased post-COVID lung function. This knowledge may guide prediction and further understanding of long-term sequelae of COVID-19 infection.