Daniel Xie

Daniel Xie

Auto-generated profile, based on publicly available information

Daniel Xie

Lawrence Berkeley National Laboratory, Berkeley, CA, USA

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
HZH. W. Zhao
H. W. Zhao
Liangting SUNLiangting SUN
Liangting SUN
JGJ. W. Guo
J. W. Guo
WZW. H. Zhang
W. H. Zhang
WLW. Lu
W. Lu
DXD. Z. Xie
D. Z. Xie
The development of superconducting ECR source with higher magnetic fields and higher microwave frequency is the most straight forward path to achieve higher beam intensity and higher charge state performance. SECRAL, a superconducting third generation ECR ion source, is designed for 24-28 GHz microwave frequency operation with an innovative magnet configuration of sextupole coils located outside the three solenoids. SECRAL at 24 GHz has already produced a number of record beam intensities, such as 40Ar12+ 1.4 emA, 129Xe26+ 1.1 emA, 129Xe30+ 0.36 emA, and 209Bi31+ 0.68 emA. SECRAL-II, an upgraded version of SECRAL, was built successfully in less than 3 years and has recently been commissioned at full power of a 28 GHz gyrotron and three-frequency heating (28 + 45 + 18 GHz). New record beam intensities for highly charged ion production have been achieved, such as 620 eμA 40Ar16+, 15 eμA 40Ar18+, 146 eμA 86Kr28+, 0.5 eμA 86Kr33+, 53 eμA 129Xe38+, and 17 eμA 129Xe42+. Recent beam test results at SECRAL and SECRAL II have demonstrated that the production of more intense highly charged heavy ion beams needs higher microwave power and higher frequency, as the scaling law predicted. A 45 GHz superconducting ECR ion source FECR (a first fourth generation ECR ion source) is being built at IMP. FECR will be the world’s first Nb3Sn superconducting-magnet-based ECR ion source with 6.5 T axial mirror field, 3.5 T sextupole field on the plasma chamber inner wall, and 20 kW at a 45 GHz microwave coupling system. This paper will focus on SECRAL performance studies at 24-28 GHz and technical design of 45 GHz FECR, which demonstrates a technical path for highly charged ion beam production from 24 to 28 GHz SECRAL to 45 GHz FECR.

1 March 2013 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
YYY. Yang
Y. Yang
ZZZ. M. Zhang
Z. M. Zhang
QWQ. Wu
Q. Wu
WZW. H. Zhang
W. H. Zhang
HMH. Y. Ma
H. Y. Ma
DXD. Z. Xie
D. Z. Xie
A low energy beam transport (LEBT) system has been built for a compact pulsed hadron source (CPHS) at Tsinghua University in China. The LEBT, consisting of two solenoids and three short-drift sections, transports a pulsed proton beam of 60 mA of energy of 50 keV to the entrance of a radio frequency quadrupole (RFQ). Measurement has shown a normalized RMS beam emittance less than 0.2 π mm mrad at the end of the LEBT. Beam simulations were carried out to compare with the measurement and are in good agreement. Based on the successful CPHS LEBT development, a new LEBT for a China ADS projector has been designed. The features of the new design, including a beam chopper and beam simulations of the LEBT are presented and discussed along with CPHS LEBT development in this article.

29 September 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
DXD. Z. Xie
D. Z. Xie
JBJ. Y. Benitez
J. Y. Benitez
AHA. Hodgkinson
A. Hodgkinson
TLT. Loew
T. Loew
CLC. M. Lyneis
C. M. Lyneis
DTD. S. Todd
D. S. Todd
To demonstrate a Mixed Axial and Radial field System (MARS) as the best magnet scheme for future ECRISs, MARS-D, a demonstrative ECRIS using a NbTi MARS magnet is progressing at Lawrence Berkeley National Laboratory. An optimized MARS design can use either NbTi or Nb3Sn coils with reduced engineering complexities to construct the needed high-field magnets. The optimized magnet design could enhance MARS-D to a next generation ECRIS by producing minimum-B field maxima of 5.6 T axially and 3.2 T radially for operating frequencies up to 45 GHz. In-progress test winding has achieved a milestone demonstrating the fabrication feasibility of a MARS closed-loop coil.

11 January 2018 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
Liangting SUNLiangting SUN
Liangting SUN
WLWang Lu
Wang Lu
EMEnming Mei
Enming Mei
GSGianLuca Sabbi
GianLuca Sabbi
WWWei Wu
Wei Wu
HZHongwei Zhao
Hongwei Zhao
Modern heavy ion accelerators require intense heavy ion beams with high charge state. Electron cyclotron resonance (ECR) sources are the primary tool for generating such beams, making them indispensable devices for heavy ion physics research. Remarkable performance advancements were obtained during the last decades. At present, state of the art “third generation” ECR ion sources are based on magnets built with NbTi conductor. However, future nuclear physics facilities will require significant improvement in beam intensity and quality, which can only be met by ECR sources operating at higher frequency and field. These fourth generation machines will need to incorporate a sophisticated sextupole magnet built with high performance Nb 3 Sn or NbTi conductor. In this paper, we review the technical challenges and worldwide progress in developing high performance superconducting ECR ion sources, and discuss the development of both third and fourth generation ECR ion source magnets at IMP.

15 January 2018 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Open access
ERE. Ravaioli
E. Ravaioli
SZS. J. Zheng
S. J. Zheng
AHA. Ray Hafalia
A. Ray Hafalia
MJM. Juchno
M. Juchno
WLW. Lu
W. Lu
HZH. W. Zhao
H. W. Zhao
Lawrence Berkeley National Laboratory in collaboration with the Institute of Modern Physics has developed a Nb 3 Sn-based superconducting magnet system for a fourthgeneration electron cyclotron resonance source, with a goal of achieving the magnetic field required for operating at the microwave frequency of 45 GHz. The magnet system is composed of one sextupole magnet inside three solenoids of different sizes manufactured from Nb 3 Sn round wire. Given the high stored energy density and relatively low wire copper fraction, the coils are not self-protected in the case of a quench. The study of the transient following a quench is carried out by means of the lumped-element dynamic electro-thermal program, which includes a detailed simulation of the interfilament coupling losses developing in the wire. Nonlinear effects occurring in the magnet, such as coupling loss and differential inductance reduction, have a significant impact on protecting these magnets. The resulting baseline quench protection strategy based on four independent energy extraction systems protecting the four magnets meets the quench protection requirements. Furthermore, in order to enhance the redundancy of the quench protection system and reduce the peak voltages to ground, the implementation of a coupling-loss induced quench (CLIQ) system is considered.

10 March 2022 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
MJM. Juchno
M. Juchno
JBJ. Y. Benitez
J. Y. Benitez
JDJ. Doyle
J. Doyle
AHA. Hodgkinson
A. Hodgkinson
TLT. Leow
T. Leow
DXD. Vv Z. Xie
D. Vv Z. Xie
Superconducting electron cyclotron resonance ion sources (ECRISs) using NbTi coils and optimized for 28 GHz resonant heating have been successfully operated for almost two decades. Moving to higher heating frequencies requires increased magnetic fields, but traditional racetrack-and-solenoid ECRIS structures are at their limit using NbTi. Rather than moving to a superconductor untested in this field, the Mixed Axial and Radial field System (MARS) being developed at Lawrence Berkeley National Laboratory employs a novel closed-loop-coil design that more efficiently utilizes conductor fields and will allow the use of NbTi in a next-generation, 45 GHz ECRIS. This article presents the design of the shell-based support structure central to the MARS-D magnet design, as well as structural analysis of its components and optimization of pre-load parameters that will guarantee its successful operation.