William da Rosa Fröhlich

William da Rosa Fröhlich

Auto-generated profile, based on publicly available information

William da Rosa Fröhlich

PUCRS,Porto Alegre,Brazil

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2023 in Future Generation Computer Systems
Verified
Journal Article
Closed access
WFWilliam da Rosa Fröhlich
William da Rosa Fröhlich
SRSandro José Rigo
Sandro José Rigo
MBMarta Rosecler Bez
Marta Rosecler Bez

12 October 2023
Verified
Book Chapter
Closed access
PDF file
DSDiego Pinheiro da Silva
Diego Pinheiro da Silva
WFWilliam da Rosa Fröhlich
William da Rosa Fröhlich
MSMarco Antonio Schwertner
Marco Antonio Schwertner
SRSandro José Rigo
Sandro José Rigo

27 June 2023
Verified
Conference Paper
Open access
PDF file
WFWilliam da Rosa Fröhlich
William da Rosa Fröhlich
SRSandro José Rigo
Sandro José Rigo
MBMarta Bez
Marta Bez
Stress is one relevant cause of diseases nowadays, and prolonged exposure to stress can cause a disturbance in the allostatic load. Alternatives have been sought to deal with this situation and verify the impact of this allostatic load disorder. Wearable sensors are an option for automatically identifying acute stress since they can measure signs such as electrocardiogram, heart rate, electroencephalogram, electromyogram, or galvanic skin response. All these signals have intrinsic characteristics in a normal state and change if associated with stress occurrence. The literature presents Machine Learning Approaches and Deep Learning Models as alternatives to pattern detection in physiological signals. Nevertheless, we identify a gap regarding the allostatic load impact identification and the real-time classification when using these models. this article aims to acquire data in stress induction experiments in clinical and non-clinical patients, train a machine learning model, and, in sequence, carry out a new experiment to evaluate the classification in near real-time. The classification experiment presented results with accuracy above 92.72%. When it comes to real-time classification experiments we obtained an accuracy of 78.93%. Evaluating participants in experiments divided into clinical and non-clinical groups, a decrease of 5% in precision was identified. Based on the results obtained, we verified that the allostatic load can present challenges for real-time stress classification.

25 February 2025
Verified
Conference Paper
Closed access
WFWilliam da Rosa Fröhlich
William da Rosa Fröhlich
RBRafael Bittencourt
Rafael Bittencourt
SRSandro José Rigo
Sandro José Rigo
RBRafael Baptista
Rafael Baptista
César MarconCésar Marcon
César Marcon
In gait analysis, precise results typically depend on gold-standard techniques such as motion capture with kinematics cameras and force platforms in biomechanics labs. However, these methods are costly, time-consuming, and require controlled environments, limiting their accessibility for clinical and research use. This study investigates inertial measurement units as a costeffective wearable circuit implementation alternative. We focused on extracting features from inertial data, such as acceleration and angular velocity. We derived metrics like speed and angular acceleration to approximate the accuracy of camera kinematic data. After extensive preprocessing of inertial data and kinematic datasets, we explored alternatives, including Pearson correlation and cross-correlation analyses, to identify significant relationships between the data sources. The highest correlated features were used to train machine learning models, which were then analyzed using clustering techniques to evaluate the consistency and reliability of the results. The findings show that certain inertial data aspects strongly correlate with kinematic outcomes, indicating that inertial data can replicate results traditionally obtained through more complex methods under specific conditions.