Christophe Meyer

Christophe Meyer

Auto-generated profile, based on publicly available information

Christophe Meyer

Service de Chirurgie Maxillo-Faciale, Stomatologie et Odontologie Hospitalière, CHU Besançon, F-25000 Besançon, France

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2021 in Membranes
Verified
Journal Article
Open access
PDF file
MFMathilde FENELON
Mathilde FENELON
SCSylvain Catros
Sylvain Catros
CMChristophe Meyer
Christophe Meyer
JFJean-Christophe Fricain
Jean-Christophe Fricain
LOLaurent Obert
Laurent Obert
Florelle GindrauxFlorelle Gindraux
Florelle Gindraux
An important component of tissue engineering (TE) is the supporting matrix upon which cells and tissues grow, also known as the scaffold. Scaffolds must easily integrate with host tissue and provide an excellent environment for cell growth and differentiation. Human amniotic membrane (hAM) is considered as a surgical waste without ethical issue, so it is a highly abundant, cost-effective, and readily available biomaterial. It has biocompatibility, low immunogenicity, adequate mechanical properties (permeability, stability, elasticity, flexibility, resorbability), and good cell adhesion. It exerts anti-inflammatory, antifibrotic, and antimutagenic properties and pain-relieving effects. It is also a source of growth factors, cytokines, and hAM cells with stem cell properties. This important source for scaffolding material has been widely studied and used in various areas of tissue repair: corneal repair, chronic wound treatment, genital reconstruction, tendon repair, microvascular reconstruction, nerve repair, and intraoral reconstruction. Depending on the targeted application, hAM has been used as a simple scaffold or seeded with various types of cells that are able to grow and differentiate. Thus, this natural biomaterial offers a wide range of applications in TE applications. Here, we review hAM properties as a biocompatible and degradable scaffold. Its use strategies (i.e., alone or combined with cells, cell seeding) and its degradation rate are also presented.

11 February 2015 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
MWMariska Wesseling
Mariska Wesseling
FGFriedl de Groote
Friedl de Groote
CMChristophe Meyer
Christophe Meyer
KCKristoff Corten
Kristoff Corten
JSJean‐Pierre Simon
Jean‐Pierre Simon
IJIlse Jonkers
Ilse Jonkers
Patients with hip pathology present alterations in gait which have an effect on joint moments and loading. In knee osteoarthritic patients, the relation between medial knee contact forces and the knee adduction moment are currently being exploited to define gait retraining strategies to effectively reduce pain and disease progression. However, the relation between hip contact forces and joint moments has not been clearly established. Therefore, this study aims to investigate the effect of changes in hip and pelvis kinematics during gait on internal hip moments and contact forces which is calculated using muscle driven simulations. The results showed that frontal plane kinetics have the largest effect on hip contact forces. Given the high correlation between the change in hip adduction moment and contact force at initial stance ( R 2 = 0.87), this parameter can be used to alter kinematics and predict changes in contact force. At terminal stance the hip adduction and flexion moment can be used to predict changes in contact force ( R 2   = 0.76). Therefore, gait training that focuses on decreasing hip adduction moments, a wide base gait pattern, has the largest potential to reduce hip contact forces. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:1094–1102, 2015.

19 November 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CMChristophe Meyer
Christophe Meyer
KCKristoff Corten
Kristoff Corten
MWMariska Wesseling
Mariska Wesseling
KPKoen Peers
Koen Peers
JSJean-Pierre Simon
Jean-Pierre Simon
KDKaat Desloovere
Kaat Desloovere
The burden of hip muscles weakness and its relation to other impairments has been well documented. It is therefore a pre-requisite to have a reliable method for clinical assessment of hip muscles function allowing the design and implementation of a proper strengthening program. Motor-driven dynamometry has been widely accepted as the gold-standard for lower limb muscle strength assessment but is mainly related to the knee joint. Studies focusing on the hip joint are less exhaustive and somewhat discrepant with regard to optimal participants position, consequently influencing outcome measures. Thus, we aimed to develop a standardized test setup for the assessment of hip muscles strength, i.e. flexors/extensors and abductors/adductors, with improved participant stability and to define its psychometric characteristics. Eighteen participants performed unilateral isokinetic and isometric contractions of the hip muscles in the sagittal and coronal plane at two separate occasions. Peak torque and normalized peak torque were measured for each contraction. Relative and absolute measures of reliability were calculated using the intraclass correlation coefficient and standard error of measurement, respectively. Results from this study revealed higher levels of between-day reliability of isokinetic/isometric hip abduction/flexion peak torque compared to existing literature. The least reliable measures were found for hip extension and adduction, which could be explained by a less efficient stabilization technique. Our study additionally provided a first set of reference normalized data which can be used in future research.

1 January 2018 in Gait & Posture
Verified
Journal Article
Closed access
CMChristophe A.G. Meyer
Christophe A.G. Meyer
MWMariska Wesseling
Mariska Wesseling
KCKristoff Corten
Kristoff Corten
ANAngela Nieuwenhuys
Angela Nieuwenhuys
DMDavide Monari
Davide Monari
KDKaat Desloovere
Kaat Desloovere

9 December 2014 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
MWMariska Wesseling
Mariska Wesseling
LDLoes C. Derikx
Loes C. Derikx
FGFriedl de Groote
Friedl de Groote
WBWard Bartels
Ward Bartels
CMChristophe Meyer
Christophe Meyer
IJIlse Jonkers
Ilse Jonkers
In musculoskeletal modelling, several optimization techniques are used to calculate muscle forces, which strongly influence resultant hip contact forces (HCF). The goal of this study was to calculate muscle forces using four different optimization techniques, i.e., two different static optimization techniques, computed muscle control (CMC) and the physiological inverse approach (PIA). We investigated their subsequent effects on HCFs during gait and sit to stand and found that at the first peak in gait at 15–20% of the gait cycle, CMC calculated the highest HCFs (median 3.9 times peak GRF (pGRF)). When comparing calculated HCFs to experimental HCFs reported in literature, the former were up to 238% larger. Both static optimization techniques produced lower HCFs (median 3.0 and 3.1 pGRF), while PIA included muscle dynamics without an excessive increase in HCF (median 3.2 pGRF). The increased HCFs in CMC were potentially caused by higher muscle forces resulting from co‐contraction of agonists and antagonists around the hip. Alternatively, these higher HCFs may be caused by the slightly poorer tracking of the net joint moment by the muscle moments calculated by CMC. We conclude that the use of different optimization techniques affects calculated HCFs, and static optimization approached experimental values best. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:???–???, 2015.

18 May 2015 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
CMChristophe A.G. Meyer
Christophe A.G. Meyer
KCKristoff Corten
Kristoff Corten
SFSteffen Fieuws
Steffen Fieuws
KDKevin Deschamps
Kevin Deschamps
DMDavide Monari
Davide Monari
KDKaat Desloovere
Kaat Desloovere
Critical appraisal of the literature highlights that the discriminative power of gait‐related features in patients with hip osteoarthritis (OA) has not been fully explored. We aimed to reduce the number of gait‐related features and define the most discriminative ones comparing the three‐dimensional gait analysis of 20 patients with hip osteoarthritis (OA) with those of 17 healthy peers. First, principal component analysis was used to reduce the high‐dimensional gait data into a reduced set of interpretable variables for further analysis, including tests for group differences. These differences were indicative for the selection of the top 10 variables to be included into linear discriminant analysis models (LDA). Our findings demonstrated the successful data reduction of hip osteoarthritic‐related gait features with a high discriminatory power. The combination of the top variables into LDA models clearly separated groups, with a maximum misclassification error rate of 19%, estimated by cross‐validation. Decreased hip/knee extension, hip flexion and internal rotation moment were gait features with the highest discriminatory power. This study listed the most clinically relevant gait features characteristics of hip OA. Moreover, it will help clinicians and physiotherapists understand the movement pathomechanics related to hip OA useful in the management and design of rehabilitation intervention. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:1498–1507, 2015.