Marián Mikula

Marián Mikula

Auto-generated profile, based on publicly available information

Marián Mikula

Comenius University in Bratislava

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2020 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Open access
PDF file
VŠViktor Šroba
Viktor Šroba
TFTomáš Fiantok
Tomáš Fiantok
MTMartin Truchlý
Martin Truchlý
TRTomáš Roch
Tomáš Roch
MZMiroslav Zahoran
Miroslav Zahoran
MMMarián Mikula
Marián Mikula
Tantalum diboride (TaB2) belonging to the ultrahigh temperature ceramics family is proving to be a promising material for hard protective films, thanks to its high thermal stability and excellent mechanical properties. However, growth of TaB2 ± x films prepared using physical vapor deposition techniques is strongly affected by Ar neutrals reflected from a stoichiometric TaB2 target due to a significant mass difference of heavy Ta and light B atoms leading to substantial changes in the final chemical composition and structure of films. In this work, TaB2 ± x films are experimentally prepared using high target utilization sputtering. Stopping and range of ions in matter simulations are used to investigate the behavior of Ar neutrals during deposition processes. A wide range of analytical methods is used to completely characterize the chemical composition, structure, and mechanical properties of TaB2 ± x films, and the explanation of the obtained results is supported by density functional theory calculations. TaB2 ± x films grow in a broad compositional range from TaB1.36 to TaB3.84 depending on the kinetic energy of Ar neutrals. The structure of overstoichiometric TaB2 + x films consists of 0001 preferentially oriented α-TaB2 nanocolumns surrounded by a boron-tissue phase. In the case of highly understoichiometric TaB2 − x films, the boron-tissue phase disappears and the structure consisting of 0001 and 101¯1 oriented α-TaB2 nanocolumns is formed. All TaB2 ± x films exhibit excellent mechanical properties with high hardness, ranging from 27 to 43 GPa and relatively low values of Young's modulus in the range of 304–488 GPa.

29 April 2022 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Closed access
PDF file
TFTomáš Fiantok
Tomáš Fiantok
VŠViktor Šroba
Viktor Šroba
NKNikola Koutná
Nikola Koutná
VIVitalii Izai
Vitalii Izai
TRTomáš Roch
Tomáš Roch
MMMarián Mikula
Marián Mikula
Zirconium diboride (ZrB2) represents a promising hard coating material for demanding high-temperature applications and could provide an excellent basis for fine-tuning mechanical properties via the concept of alloying. Here, combining density functional theory and experiments, we investigate the effect of aluminum alloying on thermally induced structure evolution and mechanical properties of α-structured Zr1 − xAlxB2 + Δ. Ab initio calculations predict a strong tendency for spinodal phase separation of hexagonal Zr1 − xAlxB2 solid solution into isostructural binaries. Experimental results confirm predictions of the insolubility of aluminum in the ZrB2 phase when the structure of magnetron co-sputtered Zr0.72Al0.28B2.64 films with an aluminum content of 8 at. % has a nanocomposite character consisting of hexagonal α-ZrB2 nanocolumns surrounded by an amorphous Al-rich tissue phase. The films are structurally stable up to 1100 °C but out-diffusion of Al atoms from boundary regions during annealing was observed. Al alloying causes a significant decrease in hardness when the hardness of the reference as-deposited ZrB2.2 and Zr0.72Al0.28B2.64 is 39 and 23 GPa, respectively. Low hardening effect in ternaries was observed after annealing at 1000 °C when the hardness increased from 23.5 to 26.5 GPa due to the locally increased concentration of point defects at the boundaries of the nanocolumns and Al-rich tissue phases. Young's modulus decrease from 445 (ZrB2.2) to 345 GPa (Zr0.72Al0.28B2.64) indicates a change in the mechanical response of the ternary film toward more ductile behavior.

12 October 2014 in Surface and Coatings Technology
Verified
Journal Article
Closed access
MMM. Mikula
M. Mikula
TRT. Roch
T. Roch
DPD. Plašienka
D. Plašienka
LSL. Satrapinskyy
L. Satrapinskyy
PŠP. Švec
P. Švec
PKP. Kúš
P. Kúš

26 January 2024 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Open access
PDF file
VŠViktor Šroba
Viktor Šroba
KVKatarína Viskupová
Katarína Viskupová
BWBartosz Wicher
Bartosz Wicher
VRVladyslav Rogoz
Vladyslav Rogoz
XLXiao Li
Xiao Li
GGGrzegorz Greczynski
Grzegorz Greczynski
Time-resolved ion mass spectrometry is used to analyze the type and the energy of metal-ion fluxes during hybrid high-power impulse/direct-current magnetron co-sputtering (HiPIMS/DCMS) in Ar. The study focuses on the effect of HiPIMS plasma plumes on the cross-ionization of the material flux sputtered from the DCMS source. Al, Si, Ti, and Hf elemental targets are used to investigate the effect of the metal’s first ionization potential IPMe1 and mass on the extent of cross-ionization. It is demonstrated that the interaction with HiPIMS plasma results in the significant ionization of the material flux sputtered from the DCMS source. Experiments conducted with elements of similar mass but having different IPMe1 values, Si and Al (Si-HiPIMS/Al-DCMS and Al-HiPIMS/Si-DCMS) reveal that the ionization of the DCMS flux is favored if the sputtered element has lower ionization potential than the one operating in the HiPIMS mode. If elements having similar IPMe1 are used on both sources, the metal mass becomes a decisive parameter as evidenced by experiments involving Ti and Hf (Ti-HiPIMS/Hf-DCMS and Hf-HiPIMS/Ti-DCMS). In such a case, Ti+ fluxes during Hf-HiPIMS/Ti-DCMS may even exceed Hf+ fluxes from the HiPIMS cathode and are much stronger than Hf+ fluxes during Ti-HiPIMS/Hf-DCMS. The latter effect can be explained by the fact that heavier Hf+ ions require longer transit time from the ionization zone to the substrate, which effectively increases the probability of interaction between the Hf-HiPIMS plasma plume and the Ti-DCMS flux, thereby leading to higher Ti ionization. Thus, the common notion of low ionization levels associated with DCMS has to be revised if DCMS is used together with highly ionized plasmas such as HiPIMS operating at higher peak target currents. These results are particularly important for the film growth in the hybrid configuration with substrate bias pulses synchronized to specific ion types.

1 March 2023 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Closed access
PDF file
VŠViktor Šroba
Viktor Šroba
TFTomáš Fiantok
Tomáš Fiantok
MTMartin Truchly
Martin Truchly
TRTomáš Roch
Tomáš Roch
BGBranislav Grančič
Branislav Grančič
MMMarián Mikula
Marián Mikula
Alloying of transition metal diborides with other metals seems to be a suitable way to maintain their excellent mechanical properties under high-temperature loads. Here, we focus on the perspective tantalum diboride (TaB2) hard film, where we investigate the effect of aluminum alloying on the thermally induced structural evolution and mechanical properties of α-Ta1−xAlxB2 using a combination of density functional theory and experiments. Ab initio calculations predict a strong tendency toward the spinodal phase decomposition of the α-TaAlB2 solid solution into isostructural binaries in the entire concentration range at T = 0 K. However, an increase in temperature (T > 773 K) leads to stabilization of the α-Ta1−xAlxB2 solid solution at x < 0.5. The experimental results of magnetron co-sputtered Ta0.75Al0.25B2.14 and Ta0.69Al0.31B2.16 films with aluminum concentrations of 8 and 12.5 at. %, respectively, confirm the insolubility of aluminum in the TaB2 phase. The structure has a nanocomposite character formed by α-TaB2 nanofilaments surrounded by an Al-rich tissue phase. The films are structurally stable up to 1200 °C, but Al atoms already begin to diffuse from the boundary regions when the temperature exceeds 1000 °C. Al alloying causes a decrease in hardness, since the hardness of the reference as-deposited TaB1.21, Ta0.75Al0.25B2.14, and Ta0.69Al0.31B2.16 films is 34, 28, and 27 GPa, respectively. Exposing the films to high temperatures does not lead to a hardening effect; the hardness of Al-depleted films annealed at a temperature of 1200 °C decreased by approximately 10%. The decrease in Young's modulus from 420 GPa (TaB1.21) to 370 GPa (Ta0.69Al0.31B2.16) indicates a tendency toward the ductile behavior of Al alloyed films under mechanical load.

25 May 2023 in Coatings
Verified
Journal Article
Open access
PDF file
MVMarek Vidiš
Marek Vidiš
MTMartin Truchly
Martin Truchly
VIVitalii Izai
Vitalii Izai
TFTomáš Fiantok
Tomáš Fiantok
MRMiroslav Rajninec
Miroslav Rajninec
MMMarián Mikula
Marián Mikula
The use of silver-based antimicrobial materials has been growing recently. Considering the threat of developing silver-resistant bacteria, it is essential to address the endurance of such materials and the amount of silver released into the environment. Here we report on a durable, antibacterial Ag/TiBx nanocomposite coating prepared by conventional magnetron sputtering. The coating consists of fine Ag clusters embedded in extremely hard, wear-resistant overstoichiometric TiBx, which serves as a protective matrix. The highest E. coli growth inhibition of 97% is observed for the coating containing 24 at.% of Ag. A strong antibacterial effect is also maintained after 45 days of immersion in the Luria–Bertani + 5% HNO3 solution. Despite a marked hardness decrease from 40 GPa for TiBx to 6.4 GPa for Ag/TiBx with 28 at.% of Ag, the coating maintains a good specific wear rate of 6 × 10−5 mm3/Nm. Moreover, the addition of Ag, which acts as a solid lubricant, decreases the coefficient of friction from 0.77 to 0.35, even at room temperature. Thanks to the combination of antibacterial properties and enhanced wear resistance, such material can find application as a protective coating for cutlery, door handles, water taps, and other daily-used objects in public areas.