Roberto Miguel Lang

Roberto Miguel Lang

Auto-generated profile, based on publicly available information

Roberto Miguel Lang

University of Chicago Medical Center, Chicago, Illinois, USA

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2005 in European Heart Journal
Verified
Journal Article
Open access
PDF file
LJLawrence D. Jacobs
Lawrence D. Jacobs
ISIvan S. Salgo
Ivan S. Salgo
SGSascha Goonewardena
Sascha Goonewardena
LWLynn Weinert
Lynn Weinert
PCPatrick Coon
Patrick Coon
RLRoberto M. Lang
Roberto M. Lang
Aims Determination of left ventricular (LV) volumes and ejection fraction (EF) from two-dimensional echocardiographic (2DE) images is subjective, time-consuming, and relatively inaccurate because of foreshortened views and the use of geometric assumptions. Our aims were (1) to validate a new method for rapid, online measurement of LV volumes from real-time three-dimensional echocardiographic (RT3DE) data using cardiac magnetic resonance (CMR) as the reference and (2) to compare its accuracy and reproducibility with standard 2DE measurements. Methods and results CMR, 2DE, and RT3DE datasets were obtained in 50 patients. End-systolic and end-diastolic volumes (ESV and EDV) were calculated from the 2DE images using biplane method of disks. ES and ED RT3DE datasets were analysed using prototype software designed to automatically detect the endocardial surface using a deformable shell model and calculate ESV and EDV from voxel counts. 2DE and RT3DE-derived volumes were compared with CMR (linear regression, Bland–Altman analysis). In most patients, analysis of RT3DE data required <2 min per patient. RT3DE measurements correlated highly with CMR (r: 0.96, 0.97, and 0.93 for EDV, ESV, and EF, respectively) with small biases (−14 mL, −6.5 mL, −1%) and narrow limits of agreement (SD: 17 mL, 16 mL, 6.4%). 2DE measurements correlated less well with CMR (r: 0.89, 0.92, 0.86) with greater biases (−23 mL, −15 mL, 1%) and wider limits of agreement (SD: 29 mL, 24 mL, 9.5%). RT3DE resulted in lower intra-observer (EDV: 7.9 vs. 23%; ESV: 7.6 vs. 26%) and inter-observer variability (EDV: 11 vs. 26%; ESV: 13 vs. 31%). Conclusion Semi-automated detection of the LV endocardial surface from RT3DE data is suitable for clinical use because it allows rapid, accurate, and reproducible measurements of LV volumes, superior to conventional 2DE methods.

1 November 2006 in JACC
Verified
Journal Article
Closed access
RLRoberto M. Lang
Roberto M. Lang
VMVictor Mor-Avi
Victor Mor-Avi
LSLissa Sugeng
Lissa Sugeng
PNPetra S. Nieman
Petra S. Nieman
DSDavid J. Sahn
David J. Sahn

1 January 2012 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
BFBenjamin H Freed
Benjamin H Freed
MGMardi Gomberg-Maitland
Mardi Gomberg-Maitland
SCSonal Chandra
Sonal Chandra
VMVictor Mor-Avi
Victor Mor-Avi
SRStuart Rich
Stuart Rich
APAmit Patel
Amit Patel
Late gadolinium enhancement (LGE) occurs at the right ventricular (RV) insertion point (RVIP) in patients with pulmonary hypertension (PH) and has been shown to correlate with cardiovascular magnetic resonance (CMR) derived RV indices. However, the prognostic role of RVIP-LGE and other CMR-derived parameters of RV function are not well established. Our aim was to evaluate the predictive value of contrast-enhanced CMR in patients with PH. RV size, ejection fraction (RVEF), and the presence of RVIP-LGE were determined in 58 patients with PH referred for CMR. All patients underwent right heart catheterization, exercise testing, and N-terminal pro-brain natriuretic peptide (NT-proBNP) evaluation; results of which were included in the final analysis if performed within 4 months of the CMR study. Patients were followed for the primary endpoint of time to clinical worsening (death, decompensated right ventricular heart failure, initiation of prostacyclin, or lung transplantation). Overall, 40/58 (69%) of patients had RVIP-LGE. Patients with RVIP- LGE had larger right ventricular volume index, lower RVEF, and higher mean pulmonary artery pressure (mPAP), all p < 0.05. During the follow-up period of 10.2 ± 6.3 months, 19 patients reached the primary endpoint. In a univariate analysis, RVIP-LGE was a predictor for adverse outcomes (p = 0.026). In a multivariate analysis, CMR-derived RVEF was an independent predictor of clinical worsening (p = 0.036) along with well-established prognostic parameters such as exercise capacity (p = 0.010) and mPAP (p = 0.001). The presence of RVIP-LGE in patients with PH is a marker for more advanced disease and poor prognosis. In addition, this study reveals for the first time that CMR-derived RVEF is an independent non-invasive imaging predictor of adverse outcomes in this patient population.

1 July 2016 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
WTWendy Tsang
Wendy Tsang
ISIvan S. Salgo
Ivan S. Salgo
DMDiego Medvedofsky
Diego Medvedofsky
MTMasaaki Takeuchi
Masaaki Takeuchi
DPDavid Prater
David Prater
RLRoberto M. Lang
Roberto M. Lang

1 September 2019 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
FAFederico M. Asch
Federico M. Asch
NPNicolas Poilvert
Nicolas Poilvert
TATheodore Abraham
Theodore Abraham
MJMadeline Jankowski
Madeline Jankowski
JCJayne Cleve
Jayne Cleve
RLRoberto M. Lang
Roberto M. Lang
Background: Echocardiographic quantification of left ventricular (LV) ejection fraction (EF) relies on either manual or automated identification of endocardial boundaries followed by model-based calculation of end-systolic and end-diastolic LV volumes. Recent developments in artificial intelligence resulted in computer algorithms that allow near automated detection of endocardial boundaries and measurement of LV volumes and function. However, boundary identification is still prone to errors limiting accuracy in certain patients. We hypothesized that a fully automated machine learning algorithm could circumvent border detection and instead would estimate the degree of ventricular contraction, similar to a human expert trained on tens of thousands of images. Methods: Machine learning algorithm was developed and trained to automatically estimate LVEF on a database of >50 000 echocardiographic studies, including multiple apical 2- and 4-chamber views (AutoEF, BayLabs). Testing was performed on an independent group of 99 patients, whose automated EF values were compared with reference values obtained by averaging measurements by 3 experts using conventional volume-based technique. Inter-technique agreement was assessed using linear regression and Bland-Altman analysis. Consistency was assessed by mean absolute deviation among automated estimates from different combinations of apical views. Finally, sensitivity and specificity of detecting of EF ≤35% were calculated. These metrics were compared side-by-side against the same reference standard to those obtained from conventional EF measurements by clinical readers. Results: Automated estimation of LVEF was feasible in all 99 patients. AutoEF values showed high consistency (mean absolute deviation =2.9%) and excellent agreement with the reference values: r =0.95, bias=1.0%, limits of agreement =±11.8%, with sensitivity 0.90 and specificity 0.92 for detection of EF ≤35%. This was similar to clinicians’ measurements: r =0.94, bias=1.4%, limits of agreement =±13.4%, sensitivity 0.93, specificity 0.87. Conclusions: Machine learning algorithm for volume-independent LVEF estimation is highly feasible and similar in accuracy to conventional volume-based measurements, when compared with reference values provided by an expert panel.

5 March 2024 in European Heart Journal
Verified
Journal Article
Open access
PDF file
Denisa MuraruDenisa Muraru
Denisa Muraru
LBLuigi P. Badano
Luigi P. Badano
RHRebecca T Hahn
Rebecca T Hahn
RLRoberto M Lang
Roberto M Lang
VDVictoria Delgado
Victoria Delgado
MSMarta Sitges
Marta Sitges
Atrial secondary tricuspid regurgitation (A-STR) is a distinct phenotype of secondary tricuspid regurgitation with predominant dilation of the right atrium and normal right and left ventricular function. Atrial secondary tricuspid regurgitation occurs most commonly in elderly women with atrial fibrillation and in heart failure with preserved ejection fraction in sinus rhythm. In A-STR, the main mechanism of leaflet malcoaptation is related to the presence of a significant dilation of the tricuspid annulus secondary to right atrial enlargement. In addition, there is an insufficient adaptive growth of tricuspid valve leaflets that become unable to cover the enlarged annular area. As opposed to the ventricular phenotype, in A-STR, the tricuspid valve leaflet tethering is typically trivial. The A-STR phenotype accounts for 10%–15% of clinically relevant tricuspid regurgitation and has better outcomes compared with the more prevalent ventricular phenotype. Recent data suggest that patients with A-STR may benefit from more aggressive rhythm control and timely valve interventions. However, little is mentioned in current guidelines on how to identify, evaluate, and manage these patients due to the lack of consistent evidence and variable definitions of this entity in recent investigations. This interdisciplinary expert opinion document focusing on A-STR is intended to help physicians understand this complex and rapidly evolving topic by reviewing its distinct pathophysiology, diagnosis, and multi-modality imaging characteristics. It first defines A-STR by proposing specific quantitative criteria for defining the atrial phenotype and for discriminating it from the ventricular phenotype, in order to facilitate standardization and consistency in research.