Jacquelyn R. Brokamp

Jacquelyn R. Brokamp

Auto-generated profile, based on publicly available information

Jacquelyn R. Brokamp

Department of Mechanical Engineering, Auburn University, Auburn, AL, USA

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2025 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
JBJacquelyn R. Brokamp
Jacquelyn R. Brokamp
RPRyan Pollard
Ryan Pollard
INIvan Nail-Ulloa
Ivan Nail-Ulloa
MZMichael E. Zabala
Michael E. Zabala
Additive manufacturing enables the rapid production and customization of ankle-foot orthoses (AFOs), offering substantial advantages over traditional fabrication methods. Understanding the mechanical properties of these devices, particularly stiffness and deflection during ambulation, is essential for their effective deployment as it may inform future benchtop performance tests, such as fatigue life analysis. However, previous studies seemingly disregard the combined effects of the passive and active ankle joint contributions to stiffness during ambulation, limiting the predictive accuracy of the mechanical performance tests. Accordingly, this study investigates how the AFO-ankle complex quasi-stiffness (the combined stiffness of the AFO and the ankle joint) and participant-specific anthropometric measures (height and body mass) influence AFO deflection throughout the gait cycle. Nine healthy, unimpaired participants were fitted unilaterally with custom-fit AFOs fabricated using XO-Armor® 3D-scanning and 3D-printing technology. Gait analyses were conducted under AFO and no-AFO conditions, focusing on three subphases of stance: controlled plantarflexion (CPF), controlled dorsiflexion (CDF), and powered plantarflexion (PPF). The results revealed significant positive correlations between anthropometric measures and both AFO-ankle complex quasi-stiffness throughout stance phase and peak AFO deflection in dorsiflexion (θDF,max). Additionally, AFO-ankle complex quasi-stiffness during CDF (KAFO,CDF) exhibited an inverse relationship with θDF,max. No significant relationships were identified between maximum deflection in plantarflexion (θPF,max) and either anthropometric measures or AFO-ankle complex quasi-stiffness during CPF (KAFO,CDF). The findings of this study suggest that height, weight, and KAFO,CDF should be considered when developing standardized protocols for custom-fit AFOs to enhance the predictive accuracy of benchtop testing, particularly when estimating θDF,max.

1 November 2025 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
RPRyan Pollard
Ryan Pollard
JBJacquelyn R. Brokamp
Jacquelyn R. Brokamp
INIvan Nail-Ulloa
Ivan Nail-Ulloa
MZMichael Zabala
Michael Zabala

31 July 2026 in Journal of Biomechanics
Verified
Journal Article
Closed access
JBJacquelyn R. Brokamp
Jacquelyn R. Brokamp
RPRyan Pollard
Ryan Pollard
INIván E. Nail-Ulloa
Iván E. Nail-Ulloa
JLJacob S. Larson
Jacob S. Larson
MZMichael Zabala
Michael Zabala