Alberto Stabilini

Alberto Stabilini

Auto-generated profile, based on publicly available information

Alberto Stabilini

Paul Scherrer Institute (PSI)

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JVJosé Vedelago
José Vedelago
FGFederico A Geser
Federico A Geser
IMIván D Muñoz
Iván D Muñoz
ASAlberto Stabilini
Alberto Stabilini
EYEduardo G Yukihara
Eduardo G Yukihara
OJOliver Jäkel
Oliver Jäkel
Objective . The purpose of this study is to estimate the energy and angular distribution of secondary neutrons inside a phantom in hadron therapy, which will support decisions on detector choice and experimental setup design for in-phantom secondary neutron measurements. Approach . Dedicated Monte Carlo simulations were implemented, considering clinically relevant energies of protons, helium and carbon ions. Since scored quantities can vary from different radiation transport models, the codes FLUKA, TOPAS and MCNP were used. The geometry of an active scanning beam delivery system for heavy ion treatment was implemented, and simulations of pristine and spread-out Bragg peaks were carried out. Previous studies, focused on specific ion types or single energies, are qualitatively in agreement with the obtained results. Main results . The secondary neutrons energy distributions present a continuous spectrum with two peaks, one centred on the thermal/epithermal region, and one on the high-energy region, with the most probable energy ranging from 19 up to 240 MeV, depending on the ion type and its initial energy. The simulations show that the secondary neutron energies may exceed 400 MeV and, therefore, suitable neutron detectors for this energy range shall be needed. Additionally, the angular distribution of the low energy neutrons is quite isotropic, whereas the fast/relativistic neutrons are mainly scattered in the down-stream direction. Significance . It would be possible to minimize the influence of the heavy ions when measuring the neutron-generated recoil protons by selecting appropriate measurement positions within the phantom. Although there are discrepancies among the three Monte Carlo codes, the results agree qualitatively and in order of magnitude, being sufficient to support further investigations with the ultimate goal of mapping the secondary neutron doses both in- and out-of-field in hadrontherapy. The obtained secondary neutron spectra are available as supplementary material.

21 January 2023 in Radiation and Environmental Biophysics
Verified
Journal Article
Open access
PDF file
ASAlberto Stabilini
Alberto Stabilini
LHLuana Hafner
Luana Hafner
LWLinda Walsh
Linda Walsh
In assessments of detrimental health risks from exposures to ionising radiation, many forms of risk to dose–response models are available in the literature. The usual practice is to base risk assessment on one specific model and ignore model uncertainty. The analysis illustrated here considers model uncertainty for the outcome all solid cancer incidence, when modelled as a function of colon organ dose, using the most recent publicly available data from the Life Span Study on atomic bomb survivors of Japan. Seven recent publications reporting all solid cancer risk models currently deemed plausible by the scientific community have been included in a model averaging procedure so that the main conclusions do not depend on just one type of model. The models have been estimated with different baselines and presented for males and females at various attained ages and ages at exposure, to obtain specially computed model-averaged Excess Relative Risks (ERR) and Excess Absolute Risks (EAR). Monte Carlo simulated estimation of uncertainty on excess risks was accounted for by applying realisations including correlations in the risk model parameters. Three models were found to weight the model-averaged risks most strongly depending on the baseline and information criteria used for the weighting. Fitting all excess risk models with the same baseline, one model dominates for both information criteria considered in this study. Based on the analysis presented here, it is generally recommended to take model uncertainty into account in future risk analyses.

15 April 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
DBDavid Breitenmoser
David Breitenmoser
ASAlberto Stabilini
Alberto Stabilini
MKMalgorzata Magdalena Kasprzak
Malgorzata Magdalena Kasprzak
SMSabine Mayer
Sabine Mayer

2 January 2024 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
FGFederico A Geser
Federico A Geser
ASAlberto Stabilini
Alberto Stabilini
JCJeppe Brage Christensen
Jeppe Brage Christensen
IMIván D Muñoz
Iván D Muñoz
EYEduardo G Yukihara
Eduardo G Yukihara
JVJosé Vedelago
José Vedelago
Objective. To study the secondary neutrons generated by primary oxygen beams for cancer treatment and compare the results to those from primary protons, helium, and carbon ions. This information can provide useful insight into the positioning of neutron detectors in phantom for future experimental dose assessments. Approach. Mono-energetic oxygen beams and spread-out Bragg peaks were simulated using the Monte Carlo particle transport codes FLUktuierende KAskade, tool for particle simulation, and Monte Carlo N-Particle, with energies within the therapeutic range. The energy and angular distribution of the secondary neutrons were quantified. Main results. The secondary neutron spectra generated by primary oxygen beams present the same qualitative trend as for other primary ions. The energy distributions resemble continuous spectra with one peak in the thermal/epithermal region, and one other peak in the fast/relativistic region, with the most probable energy ranging from 94 up to 277 MeV and maximum energies exceeding 500 MeV. The angular distribution of the secondary neutrons is mainly downstream-directed for the fast/relativistic energies, whereas the thermal/epithermal neutrons present a more isotropic propagation. When comparing the four different primary ions, there is a significant increase in the most probable energy as well as the number of secondary neutrons per primary particle when increasing the mass of the primaries. Significance. Most previous studies have only presented results of secondary neutrons generated by primary proton beams. In this work, secondary neutrons generated by primary oxygen beams are presented, and the obtained energy and angular spectra are added as supplementary material. Furthermore, a comparison of the secondary neutron generation by the different primary ions is given, which can be used as the starting point for future studies on treatment plan comparison and secondary neutron dose optimisation. The distal penumbra after the maximum dose deposition appears to be a suitable location for in-phantom dose assessments.

16 March 2024 in Radiation Measurements
Verified
Journal Article
Open access
SSStefan Schmidt
Stefan Schmidt
ASAlberto Stabilini
Alberto Stabilini
LTLong-Yang J. Thai
Long-Yang J. Thai
EYEduardo G. Yukihara
Eduardo G. Yukihara
OJOliver Jäkel
Oliver Jäkel
JVJosé Vedelago
José Vedelago

20 April 2025 in Medical Physics
Verified
Journal Article
Open access
SSStefan Schmidt
Stefan Schmidt
JCJeppe Brage Christensen
Jeppe Brage Christensen
BLBenjamin Lutz
Benjamin Lutz
ASAlberto Stabilini
Alberto Stabilini
EYEduardo G. Yukihara
Eduardo G. Yukihara
JVJosé Vedelago
José Vedelago
Background: In ion beam radiotherapy, treatment radiation fields are inevitably contaminated with secondary neutrons. The energies of these neutrons can reach several hundreds of MeV. Fluorescent nuclear track detectors (FNTDs) offer a promising solution for dosimetry of fast and high‐energy neutrons, particularly given their low linear energy transfer in water (LET) detection threshold. Purpose: This study presents an experimental FNTD sensitivity analysis in six fast mono‐energetic neutron fields, comparing the response to poly allyl diglycol carbonate (PADC) neutron detectors, and investigates the feasibility of estimating ambient dose equivalent for neutrons, (10). Moreover, it investigates the impact of converter thickness on the detector signal for both fast and high‐energy neutrons and analyzes the resulting differences in signal. Methods: FNTDs and PADCs were exposed to mono‐energetic neutron fields with energies of 1.2 MeV, 2.5 MeV, 5 MeV, 6.5 MeV, 14.8 MeV, and 19 MeV and evaluated based on the track density. The (10) values for FNTDs were determined by applying energy calibration factors, , which were determined through Monte Carlo (MC) simulations. The benchmarked MC model is employed to investigate the sensitivity of FNTDs to high‐energy neutrons up to 200 MeV for various polyethylene (PE) converter thicknesses and to analyze the detector signal, including the particle type and the recoil proton LET. Results: The sensitivity values revealed an energy dependence for FNTDs, with variations by a factor of up to 23, whereas PADC detectors showed a smaller variation, ranging from 3 to 12. Accurate (10) estimation can be achieved employing MC‐derived factors, with deviations not exceeding . The sensitivity values increased almost continuously up to for PE converter thicknesses above , whereas plateaued for thinner PE converters above 10 MeV to 15 MeV. For neutrons above , the generated fragments are deuterons, tritons and , which constitutes up to or more of the total fluence in a neutron field. The recoil proton LET dropped from approximately to nearly one order of magnitude less between 1.2 MeV and 19 MeV, with an average LET of approximately at . Conclusions: This study compares FNTD and PADC detector sensitivities, demonstrating a notable energy and converter thickness dependence for FNTDs, which is essential for precise dosimetry. Accurate (10) values for fast mono‐energetic neutrons up to were determined utilizing MC simulations. A benchmarked MC model for fast neutrons was then applied to analyze the FNTD signal for high‐energy neutrons.