Pierre Chatelain

Pierre Chatelain

Auto-generated profile, based on publicly available information

Pierre Chatelain

Université de Rennes 1, IRISA, France

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2017 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
PCPierre Chatelain
Pierre Chatelain
AKAlexandre Krupa
Alexandre Krupa
NNNassir Navab
Nassir Navab
We present a control framework for optimizing image quality during robotic ultrasound acquisitions. The quality of the ultrasound signal across the field of view is represented by a confidence map that is computed online from the B-mode frames, following a model of sound propagation. Moments extracted from this confidence map are used to design a control law for optimizing imaging quality, based on the task function approach. The proposed confidence control is combined with force and position control to build two illustrative applications. First, we use force control and confidence control in order to maintain a correct pressure and a good orientation of the probe during teleoperation. Thus, control is shared between a human operator and the robot. Then, we add an automatic positioning task, so that the quality is optimized while maintaining a target in the image center. We show experimentally that confidence-driven control can effectively optimize the acoustic window in real time. In addition, we show that it can improve the tracking robustness, by preventing the target from being shadowed. Finally, we present the results of experiments performed on a human volunteer.

1 May 2015
Verified
Conference Paper
Closed access
PCPierre Chatelain
Pierre Chatelain
AKAlexandre Krupa
Alexandre Krupa
NNNassir Navab
Nassir Navab
In this paper we propose a new ultrasound-based visual servoing framework, for the optimization of the positioning of an ultrasound probe manipulated by a robotic arm, in order to improve the quality of the acquired ultrasound images. To this end, we use the recent framework of ultrasound confidence map, which aims at estimating the perpixel quality of the ultrasound signal based on a model of sound propagation in soft tissues. More specifically, we treat the ultrasound confidence maps as a new modality to design a visual servoing control law for image quality optimization. The proposed framework aims at improving ultrasound imaging techniques, such as robotic tele-echography, target tracking or volume reconstruction. Here we illustrate our approach with the application of robotic tele-echography. Experiments are performed on both an ultrasound examination training phantom and ex vivo tissue samples.

1 May 2013
Verified
Conference Paper
Closed access
PCPierre Chatelain
Pierre Chatelain
AKAlexandre Krupa
Alexandre Krupa
MMMaud Marchal
Maud Marchal
In this paper, we present a method to localize and track manually inserted needles in real-time using a three-dimensional ultrasound probe mounted on a robotized arm. The system tracks the needle using online image processing. We first propose a new algorithm capable of robustly detecting a needle from the moment it is inserted, without any a priori information on the insertion direction. By combining the random sample consensus (RANSAC) algorithm with Kalman filtering in closed loop, we achieve robust real-time tracking of the needle. In addition, we propose a control scheme to automatically guide the ultrasonic probe in order to keep the needle within the field of view, while aligning its axis with the ultrasound beam. This method will ease the insertion of the needle by the operator, and allow the development of autonomous needle insertion by medical robots.

1 October 2020 in Medical Image Analysis
Verified
Journal Article
Open access
YCYifan Cai
Yifan Cai
RDRichard Droste
Richard Droste
HSHarshita Sharma
Harshita Sharma
PCPierre Chatelain
Pierre Chatelain
LDLior Drukker
Lior Drukker
JNJ. Alison Noble
J. Alison Noble
We present a novel multi-task neural network called Temporal SonoEyeNet (TSEN) with a primary task to describe the visual navigation process of sonographers by learning to generate visual attention maps of ultrasound images around standard biometry planes of the fetal abdomen, head (trans-ventricular plane) and femur. TSEN has three components: a feature extractor, a temporal attention module (TAM), and an auxiliary video classification module (VCM). A soft dynamic time warping (sDTW) loss function is used to improve visual attention modelling. Variants of the model are trained on a dataset of 280 video clips, each containing one of the three biometry planes and lasting 3-7 seconds, with corresponding real-time recorded gaze tracking data of an experienced sonographer. We report the performances of the different variants of TSEN for visual attention prediction at standard biometry plane detection. The best model performance is achieved using bi-directional convolutional long-short term memory (biCLSTM) in both TAM and VCM, and it outperforms a previous spatial model on all static and dynamic saliency metrics. As an auxiliary task to validate the clinical relevance of the visual attention modelling, the predicted visual attention maps were used to guide standard biometry plane detection in consecutive US video frames. All spatio-temporal TSEN models achieve higher scores compared to a spatial-only baseline; the best performing TSEN model achieves F1 scores on these standard biometry planes of 83.7%, 89.9% and 81.1%, respectively.

26 September 2018
Verified
Book Chapter
Closed access
PDF file
YCYifan Cai
Yifan Cai
HSHarshita Sharma
Harshita Sharma
PCPierre Chatelain
Pierre Chatelain
JNJ. Alison Noble
J. Alison Noble

1 May 2015
Verified
Conference Paper
Closed access
PCPierre Chatelain
Pierre Chatelain
AKAlexandre Krupa
Alexandre Krupa
NNNassir Navab
Nassir Navab
We present a method for the three-dimensional (3D) steering of a flexible needle under 3D ultrasound guidance. The proposed solution is based on a duty-cycling visual servoing strategy we designed in a previous work, and on a new needle tracking algorithm for 3D ultrasound. The flexible needle modeled as a polynomial curve is tracked during automatic insertion using particle filtering. This new tracking algorithm enables real-time closed-loop needle control with 3D ultrasound feedback. Experimental results of a targeting task demonstrate the robustness of the proposed tracking algorithm and the feasibility of 3D ultrasound-guided needle steering.