Paolino De Risi

Paolino De Risi

Auto-generated profile, based on publicly available information

Paolino De Risi

Department of Information Technology and Electrical Engineering, Universit degli Studi di Napoli Federico II, Naples, Italy

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2025 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
SSShifa Sulaiman
Shifa Sulaiman
PRPaolino De Risi
Paolino De Risi
FSFrancesco Schetter
Francesco Schetter
FFFanny Ficuciello
Fanny Ficuciello
Advanced control algorithms are essential for enhancing the functionality of prosthetic hands, enabling them to operate in diverse conditions. This paper presents a Model Reference Adaptive Controller (MRAC) developed for a tendon-driven soft continuum wrist, integrated into the ’PRISMA HAND II’ prosthetic hand. The primary objective of our research is to design an adaptive controller that facilitates wrist movements eliminating external disturbances while minimizing computational requirements. To achieve this, kinematic and dynamic models of the wrist are developed based on the Piece-wise Constant Curvature (PCC) hypothesis. The controller consists of a reference model generated using the PCC model, and state errors are evaluated by comparing the responses of the reference model to those of the wrist model. These errors are reduced using the MRAC approach to make the wrist’s behavior closely align with that of the reference model. Stability of the closed-loop system is ensured using the Lyapunov direct method, along with the ’New Theorem of Stability’, a replacement for Barbalat’s lemma, ensuring that the error between the reference model and the actual system converges to zero and that the adaptive gains stabilize to fixed values. The adaptive performance of the controller is evaluated through experimental validations, where the motions of the prosthetic hand attached to the wrist are treated as unknown disturbances, and the mechanical stiffness of the wrist is considered as an uncertain parameter, resulting from the degradation of the internal springs.

26 May 2026 in Digital Dentistry Journal
Verified
Journal Article
Open access
Gennaro RuggieroGennaro Ruggiero
Gennaro Ruggiero
Fernando ZaroneFernando Zarone
Fernando Zarone
Roberto SorrentinoRoberto Sorrentino
Roberto Sorrentino
AMAnnamaria Mastrosimone
Annamaria Mastrosimone
PRPaolino De Risi
Paolino De Risi
FFFanny Ficuciello
Fanny Ficuciello