Fernando Zarone

Prof. Dr. Fernando Zarone

Dipartimento di Neuroscienze, Scienze riproduttive e odontostomatologiche, Università degli Studi di Napoli Federico II, Corso Umberto I 40, 80138 Napoli, Italy
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2019 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
Fernando ZaroneFernando Zarone
Fernando Zarone
MMMaria Irene Di Mauro
Maria Irene Di Mauro
PIETRO AUSIELLOPIETRO AUSIELLO
PIETRO AUSIELLO
Gennaro RuggieroGennaro Ruggiero
Gennaro Ruggiero
Roberto SorrentinoRoberto Sorrentino
Roberto Sorrentino
The introduction of the new generation of particle-filled and high strength ceramics, hybrid composites and technopolymers in the last decade has offered an extensive palette of dental materials broadening the clinical indications in fixed prosthodontics, in the light of minimally invasive dentistry dictates. Moreover, last years have seen a dramatic increase in the patients’ demand for non-metallic materials, sometimes induced by metal-phobia or alleged allergies. Therefore, the attention of scientific research has been progressively focusing on such materials, particularly on lithium disilicate and zirconia, in order to shed light on properties, indications and limitations of the new protagonists of the prosthetic scene. This article is aimed at providing a narrative review regarding the state-of-the-art in the field of these popular ceramic materials, as to their physical-chemical, mechanical and optical properties, as well as to the proper dental applications, by means of scientific literature analysis and with reference to the authors’ clinical experience. A huge amount of data, sometimes conflicting, is available today. Both in vitro and in vivo studies pointed out the outstanding peculiarities of lithium disilicate and zirconia: unparalleled optical and esthetic properties, together with high biocompatibility, high mechanical resistance, reduced thickness and favorable wear behavior have been increasingly orientating the clinicians’ choice toward such ceramics. The noticeable properties and versatility make lithium disilicate and zirconia materials of choice for modern prosthetic dentistry, requiring high esthetic and mechanical performances combined with a minimal invasive approach, so that the utilization of such metal-free ceramics has become more and more widespread over time.

19 September 2017 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
Tim JodaTim Joda
Tim Joda
Fernando ZaroneFernando Zarone
Fernando Zarone
Marco FerrariMarco Ferrari
Marco Ferrari
The continuous development in dental processing ensures new opportunities in the field of fixed prosthodontics in a complete virtual environment without any physical model situations. The aim was to compare fully digitalized workflows to conventional and/or mixed analog-digital workflows for the treatment with tooth-borne or implant-supported fixed reconstructions. A PICO strategy was executed using an electronic (MEDLINE, EMBASE, Google Scholar) plus manual search up to 2016–09-16 focusing on RCTs investigating complete digital workflows in fixed prosthodontics with regard to economics or esthetics or patient-centered outcomes with or without follow-up or survival/success rate analysis as well as complication assessment of at least 1 year under function. The search strategy was assembled from MeSH-Terms and unspecific free-text words: {((“Dental Prosthesis” [MeSH]) OR (“Crowns” [MeSH]) OR (“Dental Prosthesis, Implant-Supported” [MeSH])) OR ((crown) OR (fixed dental prosthesis) OR (fixed reconstruction) OR (dental bridge) OR (implant crown) OR (implant prosthesis) OR (implant restoration) OR (implant reconstruction))} AND {(“Computer-Aided Design” [MeSH]) OR ((digital workflow) OR (digital technology) OR (computerized dentistry) OR (intraoral scan) OR (digital impression) OR (scanbody) OR (virtual design) OR (digital design) OR (cad/cam) OR (rapid prototyping) OR (monolithic) OR (full-contour))} AND {(“Dental Technology” [MeSH) OR ((conventional workflow) OR (lost-wax-technique) OR (porcelain-fused-to-metal) OR (PFM) OR (implant impression) OR (hand-layering) OR (veneering) OR (framework))} AND {((“Study, Feasibility” [MeSH]) OR (“Survival” [MeSH]) OR (“Success” [MeSH]) OR (“Economics” [MeSH]) OR (“Costs, Cost Analysis” [MeSH]) OR (“Esthetics, Dental” [MeSH]) OR (“Patient Satisfaction” [MeSH])) OR ((feasibility) OR (efficiency) OR (patient-centered outcome))}. Assessment of risk of bias in selected studies was done at a ‘trial level’ including random sequence generation, allocation concealment, blinding, completeness of outcome data, selective reporting, and other bias using the Cochrane Collaboration tool. A judgment of risk of bias was assigned if one or more key domains had a high or unclear risk of bias. An official registration of the systematic review was not performed. The systematic search identified 67 titles, 32 abstracts thereof were screened, and subsequently, three full-texts included for data extraction. Analysed RCTs were heterogeneous without follow-up. One study demonstrated that fully digitally produced dental crowns revealed the feasibility of the process itself; however, the marginal precision was lower for lithium disilicate (LS2) restorations (113.8 μm) compared to conventional metal-ceramic (92.4 μm) and zirconium dioxide (ZrO2) crowns (68.5 μm) (p < 0.05). Another study showed that leucite-reinforced glass ceramic crowns were esthetically favoured by the patients (8/2 crowns) and clinicians (7/3 crowns) (p < 0.05). The third study investigated implant crowns. The complete digital workflow was more than twofold faster (75.3 min) in comparison to the mixed analog-digital workflow (156.6 min) (p < 0.05). No RCTs could be found investigating multi-unit fixed dental prostheses (FDP). The number of RCTs testing complete digital workflows in fixed prosthodontics is low. Scientifically proven recommendations for clinical routine cannot be given at this time. Research with high-quality trials seems to be slower than the industrial progress of available digital applications. Future research with well-designed RCTs including follow-up observation is compellingly necessary in the field of complete digital processing.

18 August 2016 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
Fernando ZaroneFernando Zarone
Fernando Zarone
Marco FerrariMarco Ferrari
Marco Ferrari
FMFrancesco Guido Mangano
Francesco Guido Mangano
RLRenato Leone
Renato Leone
RSRoberto Sorrentino
Roberto Sorrentino
The present paper was aimed at reporting the state of the art about lithium disilicate ceramics. The physical, mechanical, and optical properties of this material were reviewed as well as the manufacturing processes, the results of in vitro and in vivo investigations related to survival and success rates over time, and hints for the clinical indications in the light of the latest literature data. Due to excellent optical properties, high mechanical resistance, restorative versatility, and different manufacturing techniques, lithium disilicate can be considered to date one of the most promising dental materials in Digital Dentistry.

1 June 2021 in Journal of Dentistry
Verified
Journal Article
Open access
Fernando ZaroneFernando Zarone
Fernando Zarone
Gennaro RuggieroGennaro Ruggiero
Gennaro Ruggiero
RLRenato Leone
Renato Leone
Lorenzo BreschiLorenzo Breschi
Lorenzo Breschi
Stefania LeuciStefania Leuci
Stefania Leuci
Roberto SorrentinoRoberto Sorrentino
Roberto Sorrentino
This paper aimed to provide a literature review of the mechanical and biological properties of zirconia-reinforced lithium silicate glass-ceramics (ZLS) in Computer-aided design / Computer-aided manufacturing (CAD/CAM) systems. An extensive search of the literature for papers related to ZLS was made on the databases of PubMed/Medline, Scopus, Embase, Google Scholar, Dynamed, and Open Grey. The papers were selected by 3 independent calibrated reviewers. The search strategy produced 937 records. After the removal of duplicates and the exclusion of papers that did not meet the inclusion criteria, 71 papers were included. After reviewing the included records, it was found that two types of ZLS (Vita Suprinity PC; Vita Zahnfabrik and Celtra Duo; Dentsply Sirona) are nowadays available on the market for CAD/CAM systems, similar in their chemical composition, microstructure, and biological-mechanical properties. ZLS is reported to be a biocompatible material, whose fracture resistance can withstand physiological chewing loads. The firing process influences the improvements of strength and fatigue failure load, with a volumetric shrinkage. To date, ZLS can be considered a viable alternative to other glass-ceramics for fixed single restorations. . As to biocompatibility and mechanical properties of ZLS, data are still scarce, often controversial and limited to short-term observational periods. These promising ceramics require further in vitro/in vivo studies to accurately define mechanical and biological properties, mainly in the long-term performance of restorations produced with such materials.

1 March 2007 in Dental Materials
Verified
Journal Article
Closed access
Fernando ZaroneFernando Zarone
Fernando Zarone
RSRoberto Sorrentino
Roberto Sorrentino
Tonino TrainiTonino Traini
Tonino Traini
DLDonato Di Lorio
Donato Di Lorio
SCSergio Caputi
Sergio Caputi

31 January 2003 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
Fernando ZaroneFernando Zarone
Fernando Zarone
Antonio ApicellaAntonio Apicella
Antonio Apicella
LNLuigi Nicolais
Luigi Nicolais
RARaffaella Aversa
Raffaella Aversa
RSRoberto Sorrentino
Roberto Sorrentino