4 May 2017 in Building Research & Information
The difference between actual and calculated energy is called the ‘energy-performance gap’. Possible explanations for this gap are construction mistakes, improper adjusting of equipment, excessive simplification in simulation models and occupant behaviour. Many researchers and governmental institutions think the occupant is the main cause of this gap. However, only limited evidence exists for this. Therefore, an analysis is presented of actual and theoretical energy consumption based on specific household types and building characteristics. Using a large dataset (1.4 million social housing households), the average actual and theoretical energy consumptions (gas and electricity) of different household types and characteristics (income level, type of income, number of occupants and their age) were compared for each energy label. Additionally, the 10% highest and lowest energy-consuming groups were analysed. The use of combinations of occupant characteristics instead of individual occupant characteristics provides new insights into the influence of the occupant on energy demand. For example, in contrast to previous studies, low-income households consume more gas per m2 (space heating and hot water) than households with a high income for all types of housing. Furthermore, the performance gap is caused not only by the occupant but also by the assumed building characteristics.
1 September 2019 in Applied Energy
5 July 2022 in Building Research & Information
Achieving energy efficiency in the built environment requires extensive efforts in the renovation and adaptation of housing stock. A promising design solution is the heat pump. While gas boiler systems are commonly used in Dutch non-profit housing stock, the share of dwellings with a heat pump grew from 1.6% in 2017 to 3.2% in 2021. However, building characteristics and the energy consumption of dwellings with a heat pump are unclear. Therefore, a dataset of 69,422 dwellings with different types of heat pumps has been examined and compared to dwellings with a traditional HR107 condensing gas boiler. This research reports average characteristics and the average actual energy consumption of dwellings with all-electric, hybrid and gas absorption heat pump systems. Dwellings with a heat pump system are on average of higher building quality, their gas consumption is lower and their electricity consumption is higher than dwellings with an HR107 condensing gas boiler. Detailed insight is provided for dwellings with different heat pump systems and for dwellings with different building characteristics. Further research to determine the energy performance of dwellings with specific heat pump configurations is recommended in light of the energy transition in the built environment.