Pierre-Guy Allinei

Pierre-Guy Allinei

Auto-generated profile, based on publicly available information

Pierre-Guy Allinei

CEA, DES, IRESNE, Nuclear Measurement Laboratory, Cadarache, Saint-Paul-lez-Durance, FRANCE

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2020 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
TMThomas Marchais
Thomas Marchais
PBPérot Bertrand
Pérot Bertrand
CCCedric Carasco
Cedric Carasco
JMJean-Luc Ma
Jean-Luc Ma
PAPierre-Guy Allinei
Pierre-Guy Allinei
JCJohann Collot
Johann Collot
Gamma logging for uranium exploration is currently based on total counting with Geiger-M|ller gas detectors or NaI(Tl) scintillators. However, the total count rate interpretation in terms of uranium concentration may be impaired in case of roll fronts, when the radioactive equilibrium of the natural 238U radioactive chain is modified by the differential leaching of uranium and its daughter radioisotopes radium, radon, etc. Indeed, in the case of secular equilibrium, more than 95 % of gamma rays emitted by uranium ores come from 214Pb and 214Bi isotopes, that are in the back-end of the 238U decay chain. These two isotopes might produce an intense gamma signal even when uranium is not present, or with a much smaller activity, in the ore. Therefore, gamma spectroscopy measurements of core samples are performed in surface with HPGe detectors to directly characterize uranium activity from the 1001 keV gamma ray of 234mPa that is in the beginning of the 238U chain. However, due to the low intensity of this gamma ray, acquisitions of several hours are needed. In view to characterize uranium concentration within a few minutes, we propose a method using both the 92 keV gamma rays of 234Th and 235U, and the 98.4 keV uranium X-ray. This last is due to uranium self-induced fluorescence caused by gamma rays of the uranium chain, mainly 214Pb and 214Bi. The gamma rays of 214Pb and 214Bi undergo scatterings in the sample leading to photons with an energy in the 100 keV range that favor photoelectric interactions, and thus fluorescence. The comparison of the uranium activity obtained with the 92 keV and 98.4 keV lines allows detecting a uranium heterogeneity in the ore. Indeed, in the case of uranium nugget, the 92 keV peak leads to underestimated uranium concentration due to gamma self-absorption, but on the contrary the 98.4 keV peak leads to an overestimation because of increased fluorescence. In order to test this new approach, tens of uranium ore samples have.

23 July 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MDM. Delarue
M. Delarue
ESE. Simon
E. Simon
PBPérot Bertrand
Pérot Bertrand
PAP.-G. Allinei
P.-G. Allinei
NEN. Estre
N. Estre
JCJ. Collot
J. Collot

16 March 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
PAP.G. Allinei
P.G. Allinei
NPN. Pérot
N. Pérot
BPB. Pérot
B. Pérot
TMT. Marchais
T. Marchais
VFV. Fondement
V. Fondement
RGR. Goupillou
R. Goupillou

1 September 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MDM. Delarue
M. Delarue
ESE. Simon
E. Simon
PBPérot Bertrand
Pérot Bertrand
PAP.G. Allinei
P.G. Allinei
NEN. Estre
N. Estre
JCJ. Collot
J. Collot

24 January 2018 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
TMT. Marchais
T. Marchais
PBPérot Bertrand
Pérot Bertrand
CCC. Carasco
C. Carasco
PAP.-G. Allinei
P.-G. Allinei
PCP. Chaussonnet
P. Chaussonnet
HTH. Toubon
H. Toubon
AREVA Mines and the Nuclear Measurement Laboratory of CEA Cadarache are collaborating to improve the sensitivity and precision of uranium concentration evaluation by means of gamma-ray measurements. This paper reports gamma-ray spectra, recorded with two high-purity germanium detectors, on standard cement blocks with increasing uranium content, and the corresponding MCNP simulations. The detailed MCNP model of detectors and experimental setup has been validated by calculation vs. experiment comparisons. An optimization of detector MCNP models is presented in this paper, as well as a comparison of different nuclear data libraries to explain missing or exceeding peaks in the simulation. Energy shifts observed between the fluorescence X-rays produced by MCNP and atomic data are also investigated, as well as gamma backscattering and beta radiation effects. The validated numerical models will be used in further studies to develop new gamma-ray spectroscopy approaches aiming at reducing acquisition times, especially for ore samples with low uranium content.

22 June 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
FSF. Salvador
F. Salvador
TMT. Marchais
T. Marchais
PBPérot Bertrand
Pérot Bertrand
PAP.-G. Allinei
P.-G. Allinei
FMF. Morales
F. Morales
FMF. Mayet
F. Mayet