Monay Mokhtar Shoushan

Monay Mokhtar Shoushan

Auto-generated profile, based on publicly available information

Monay Mokhtar Shoushan

Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2020 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
MSMonay Mokhtar Shoushan
Monay Mokhtar Shoushan
BRBersain Reyes
Bersain Reyes
AMAldo Rodrigo Mejía-Rodríguez
Aldo Rodrigo Mejía-Rodríguez
Jo Woon ChongJo Woon Chong
Jo Woon Chong
As a reliable indicator for individual's healthiness conditions, heart rate (HR) has been widely considered and used. Imaging photoplethysmography (iPPG) is recently highlighted as a promising HR measurement method, due to its non-contact characteristics, by extracting the HR from facial video recordings. In this study, we propose a camera-based HR monitoring technique that estimates HR information from iPPG signals extracted from a video sequence. Videos were recorded using a smartphone or a laptop camera. We adopted the plane-orthogonal-to-skin (POS) method to compute iPPG. The proposed method is evaluated by applying it to extract HR of 9 subjects at rest and during two motion conditions (lateral and frontal) while they were performing several respiratory maneuvers - spontaneous, metronome and forced. Automatic face detection algorithms were implemented in the proposed method. Our experimental results show that mean values of HR have error = 0.56% and accuracy = 99.44% when compared to HR calculated from the gold-standard electrocardiography (ECG) reference in diverse conditions of motions and respiratory maneuvers.

6 June 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Bengie L. OrtizBengie L. Ortiz
Bengie L. Ortiz
Jo Woon ChongJo Woon Chong
Jo Woon Chong
Vibhuti GuptaVibhuti Gupta
Vibhuti Gupta
MSMonay Shoushan
Monay Shoushan
Kwanghee JungKwanghee Jung
Kwanghee Jung
TDTim Dallas
Tim Dallas
Biometric Authentication (BA) is the process by which physiological measurements can be used to identify a specific person. BA has been implemented in various applications such as financial transactions, data privacy, and access control. Photoplethysmography (PPG) signals can be acquired from devices such as smartphones, smartwatches, or web cameras, which allow biometric signals to be readily captured. In this paper, we developed a BA classifier method for smart devices, which first reduces motion and noise artifacts (MNAs) in raw PPG signals, and then identifies subjects using the MNA-reduced PPG signals. Specifically, our BA classifier algorithm adopts an ensemble bagged trees (EBT) classifier with 16 PPG signal features from time and frequency domains. In the BA context, false positive (FP) and false negative (FN) rates are very important measurements to be considered. Acceptable FP and FN values were obtained. Experimental results show that our EBT-based BA algorithm achieved accuracy levels of 98.0% and 95.0%. Also, equal error rates (EER) measurements accomplished acceptable values of 2.42% and 5.90%.

12 May 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MSMonay Mokhtar Shoushan
Monay Mokhtar Shoushan
BRBersain Reyes
Bersain Reyes
AMAldo Rodrigo Mejía-Rodríguez
Aldo Rodrigo Mejía-Rodríguez
Jo Woon ChongJo Woon Chong
Jo Woon Chong
Heart rate variability (HRV) is a noninvasive marker for the cardiovascular system and the substantial influence of this system on the autonomous nervous system (ANS). Contact and remote photoplethysmography (PPG) proved to be a reliable means of pulse rate variability (PRV) measurement as in wearable devices or imaging PPG using video cameras with evolved technical specifications. However, PRV effectiveness remains unclear during controlled breathing rate. Specifically, respiratory rate, among other physiological factors, applies profound effects on ANS balance. In this study, we demonstrated that PRV can be a reliable marker, as HRV, during various controlled breathing rates. We evaluated the proposed PRV monitoring study against reference HRV obtained from an ECG measurement device. PRV was measured from video streams captured using a smartphone and a webcam for the upper abdominal section of healthy volunteers while in standing position and performing six different respiratory maneuvers. We evaluated frequency and nonlinear HRV indices. Agreement between all indices was tested for camera-based devices and ground truth for all performed tasks. The agreement presented a consistent mean close to 95% limit of agreement (LoA). Also, we employed spectral analysis and measured the spectral divergences, normalized root mean squared error (NRMSE), and correlation. Kullback-Leibler Divergence median and percentiles results indicate congruent spectrums, where the maximum median was 0.18. A significant spectral correlation with minimum value of 0.98, and relatively low spectrum NRMSE of 0.24 were observed. Moreover, the results led to HRV physiological related phenomena which agreed with physiologically interpretations found in the literature.