Bengie L. Ortiz

Dr. Bengie L. Ortiz

Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas, USA
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2024 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
Bengie L. OrtizBengie L. Ortiz
Bengie L. Ortiz
Vibhuti GuptaVibhuti Gupta
Vibhuti Gupta
RKRajnish Kumar
Rajnish Kumar
AJAditya Jalin
Aditya Jalin
XCXiao Cao
Xiao Cao
SCSung Won Choi
Sung Won Choi
Background: Wearable sensors are increasingly being explored in health care, including in cancer care, for their potential in continuously monitoring patients. Despite their growing adoption, significant challenges remain in the quality and consistency of data collected from wearable sensors. Moreover, preprocessing pipelines to clean, transform, normalize, and standardize raw data have not yet been fully optimized. Objective: This study aims to conduct a scoping review of preprocessing techniques used on raw wearable sensor data in cancer care, specifically focusing on methods implemented to ensure their readiness for artificial intelligence and machine learning (AI/ML) applications. We sought to understand the current landscape of approaches for handling issues, such as noise, missing values, normalization or standardization, and transformation, as well as techniques for extracting meaningful features from raw sensor outputs and converting them into usable formats for subsequent AI/ML analysis. Methods: We systematically searched IEEE Xplore, PubMed, Embase, and Scopus to identify potentially relevant studies for this review. The eligibility criteria included (1) mobile health and wearable sensor studies in cancer, (2) written and published in English, (3) published between January 2018 and December 2023, (4) full text available rather than abstracts, and (5) original studies published in peer-reviewed journals or conferences. Results: The initial search yielded 2147 articles, of which 20 (0.93%) met the inclusion criteria. Three major categories of preprocessing techniques were identified: data transformation (used in 12/20, 60% of selected studies), data normalization and standardization (used in 8/20, 40% of the selected studies), and data cleaning (used in 8/20, 40% of the selected studies). Transformation methods aimed to convert raw data into more informative formats for analysis, such as by segmenting sensor streams or extracting statistical features. Normalization and standardization techniques usually normalize the range of features to improve comparability and model convergence. Cleaning methods focused on enhancing data reliability by handling artifacts like missing values, outliers, and inconsistencies. Conclusions: While wearable sensors are gaining traction in cancer care, realizing their full potential hinges on the ability to reliably translate raw outputs into high-quality data suitable for AI/ML applications. This review found that researchers are using various preprocessing techniques to address this challenge, but there remains a lack of standardized best practices. Our findings suggest a pressing need to develop and adopt uniform data quality and preprocessing workflows of wearable sensor data that can support the breadth of cancer research and varied patient populations. Given the diverse preprocessing techniques identified in the literature, there is an urgency for a framework that can guide researchers and clinicians in preparing wearable sensor data for AI/ML applications. For the scoping review as well as our research, we propose a general framework for preprocessing wearable sensor data, designed to be adaptable across different disease settings, moving beyond cancer care.

6 June 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Bengie L. OrtizBengie L. Ortiz
Bengie L. Ortiz
Jo Woon ChongJo Woon Chong
Jo Woon Chong
Vibhuti GuptaVibhuti Gupta
Vibhuti Gupta
MSMonay Shoushan
Monay Shoushan
Kwanghee JungKwanghee Jung
Kwanghee Jung
TDTim Dallas
Tim Dallas
Biometric Authentication (BA) is the process by which physiological measurements can be used to identify a specific person. BA has been implemented in various applications such as financial transactions, data privacy, and access control. Photoplethysmography (PPG) signals can be acquired from devices such as smartphones, smartwatches, or web cameras, which allow biometric signals to be readily captured. In this paper, we developed a BA classifier method for smart devices, which first reduces motion and noise artifacts (MNAs) in raw PPG signals, and then identifies subjects using the MNA-reduced PPG signals. Specifically, our BA classifier algorithm adopts an ensemble bagged trees (EBT) classifier with 16 PPG signal features from time and frequency domains. In the BA context, false positive (FP) and false negative (FN) rates are very important measurements to be considered. Acceptable FP and FN values were obtained. Experimental results show that our EBT-based BA algorithm achieved accuracy levels of 98.0% and 95.0%. Also, equal error rates (EER) measurements accomplished acceptable values of 2.42% and 5.90%.

18 January 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
RKRajnish Kumar
Rajnish Kumar
JFJunhan Fu
Junhan Fu
Bengie L. OrtizBengie L. Ortiz
Bengie L. Ortiz
XCXiao Cao
Xiao Cao
KSKerby Shedden
Kerby Shedden
SCSung Won Choi
Sung Won Choi
Background: Twenty-four-hour heart rate (HR) integrates multiple physiological and psychological systems related to health and well-being, and can be continuously monitored in high temporal resolution over several days with wearable HR monitors. Using HR data from two independent datasets of cancer patients and their caregivers, we aimed to identify dyadic and individual patterns of 24 h HR variation and assess their relationship to demographic, environmental, psychological, and clinical variables of interest. Methods: a novel regularized approach to high-dimensional canonical correlation analysis (CCA) was used to identify factors reflecting dyadic and individual variation in the 24 h (circadian) HR trajectories of 430 people in 215 dyads, then regression analysis was used to relate these patterns to explanatory variables. Results: Four distinct factors of dyadic covariation in circadian HR were found, contributing approximately 7% to overall circadian HR variation. These factors, along with non-dyadic factors reflecting individual variation exhibited diverse and statistically robust patterns of association with explanatory variables of interest. Conclusions: Both dyadic and individual anomalies are present in the 24 h HR patterns of cancer patients and their caregivers. These patterns are largely synchronous, and their presence robustly associates with multiple explanatory variables. One notable finding is that higher mood scores in cancer patients correspond to an earlier HR nadir in the morning and higher HR during the afternoon.

Verified
Journal Article
Open access
PDF file
Bengie L. OrtizBengie L. Ortiz
Bengie L. Ortiz
Vibhuti GuptaVibhuti Gupta
Vibhuti Gupta
Jo Woon ChongJo Woon Chong
Jo Woon Chong
Kwanghee JungKwanghee Jung
Kwanghee Jung
TDTim Dallas
Tim Dallas
User authentication (UA) is the process by which biometric techniques are used by a person to gain access to a physical or virtual site. UA has been implemented in various applications such as financial transactions, data privacy, and access control. Various techniques, such as facial and fingerprint recognition, have been proposed for healthcare monitoring to address biometric recognition problems. Photoplethysmography (PPG) technology is an optical sensing technique which collects volumetric blood change data from the subject’s skin near the fingertips, earlobes, or forehead. PPG signals can be readily acquired from devices such as smartphones, smartwatches, or web cameras. Classical machine learning techniques, such as decision trees, support vector machine (SVM), and k-nearest neighbor (kNN), have been proposed for PPG identification. We developed a UA classification method for smart devices using long short-term memory (LSTM). Specifically, our UA classifier algorithm uses raw signals so as not to lose the specific characteristics of the PPG signal coming from each user’s specific behavior. In the UA context, false positive and false negative rates are crucial. We recruited thirty healthy subjects and used a smartphone to take PPG data. Experimental results show that our Bi-LSTM-based UA algorithm based on the feature-based machine learning and raw data-based deep learning approaches provides 95.0% and 96.7% accuracy, respectively.


22 November 2023
Verified
Conference Paper
Closed access
Bengie L. OrtizBengie L. Ortiz
Bengie L. Ortiz
LMLance McMahon
Lance McMahon
PHPeter Ho
Peter Ho
JCJo Woon Chong
Jo Woon Chong
Glaucoma, characterized by its damage to the retinal nerve, is one of the most statistically dominant eye diseases in the U.S. It can cause vision loss and blindness by affecting the optic nerve. As the disease progresses, it is not necessarily noticeable to patients, requiring elaborate solutions to manage this critical condition. In this paper, we propose a novel detection model that provides improved accuracy and performance in the detection of glaucoma using retinographies as input. After careful consideration, we adopted multiple features suitable for distinguishing healthy and diseased eyes. Moreover, the adoption, integration, and feature extraction of 3D meshes was a significant factor in developing our glaucoma detection system. With our acquired dataset, we compared the performance of Classification Decision Trees (CDT), Support Vector Machine (SVM), and K-Nearest Neighbor (KNN) in classifying retinographies as being healthy or having glaucoma. Experimental results show that the proposed model methodology can efficiently predict glaucoma detection with 100%, 100%, and 83.3% accuracy from CDT, SVM, and KNN, respectively.