Hyeon-Jin Kim

Hyeon-Jin Kim

Auto-generated profile, based on publicly available information

Hyeon-Jin Kim

Seoul Natl Univ, Inst Construct & Environm Engn, 1 Gwanak Ro, Seoul 08826, South Korea

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Journal of Structural Engineering
Verified
Journal Article
Closed access
PDF file
HKHyeon-Jin Kim
Hyeon-Jin Kim
Hyeon-Jong HwangHyeon-Jong Hwang
Hyeon-Jong Hwang
Hong-Gun ParkHong-Gun Park
Hong-Gun Park
For better structural performance and constructability, a concrete-encased steel column that uses a steel cage prefabricated with bolt connections was developed. The steel cage consists of longitudinal steel angles and transverse steel plates. As a fundamental verification of the proposed column, an eccentric-axial-load test was performed on eight composite column specimens. Test parameters included column type (i.e., conventional concrete-encased steel column versus proposed column), shape and spacing of transverse plate, and axial load eccentricity. The test results showed that, owing to the high flexural stiffness of the steel angles placed at the corners of the cross section, the axial strength and ductility of the proposed column were greater than those of the conventional composite column using a wide flange steel section at the center of the cross section, particularly in the large eccentricity of axial load. Z-section plates and closely spaced flat plates used for transverse reinforcement provided better lateral confinement to the concrete, thereby increasing the load-carrying capacity of the proposed columns. In general, existing design methods safely predicted the axial-flexural capacities of the specimens. Nonlinear numerical analysis was performed to verify test results. The numerical analysis results agreed with the test results in terms of yield stiffness, peak strength, and postpeak strength degradation.

1 June 2024 in Journal of Structural Engineering
Verified
Journal Article
Closed access
PDF file
HKHyeon-Jin Kim
Hyeon-Jin Kim
MPMok-In Park
Mok-In Park
Hong-Gun ParkHong-Gun Park
Hong-Gun Park
EPEun-Sang Park
Eun-Sang Park
To study the effect of Grade 700 MPa longitudinal rebars and hoops on the deformation capacity of RC and composite columns, eight rectangular columns were tested under cyclic lateral loadin...

24 July 2024 in Journal of Building Engineering
Verified
Journal Article
Closed access
HKHyeon-Jin Kim
Hyeon-Jin Kim
Hong-Gun ParkHong-Gun Park
Hong-Gun Park

24 August 2024 in Journal of Building Engineering
Verified
Journal Article
Closed access
HKHyeon-Jin Kim
Hyeon-Jin Kim
Hyeon-Jong HwangHyeon-Jong Hwang
Hyeon-Jong Hwang
Hong-Gun ParkHong-Gun Park
Hong-Gun Park
SLSeung Hwan Lee
Seung Hwan Lee

5 January 2023 in Journal of Building Engineering
Verified
Journal Article
Closed access
HKHyeon-Jin Kim
Hyeon-Jin Kim
Hong-Gun ParkHong-Gun Park
Hong-Gun Park

21 August 2025 in Engineering Structures
Verified
Journal Article
Closed access
HKHyeon-Jin Kim
Hyeon-Jin Kim
Hong-Gun ParkHong-Gun Park
Hong-Gun Park