Nanjia Li

Nanjia Li

Auto-generated profile, based on publicly available information

Nanjia Li

Department of Electrical Engineering, Tsinghua University, Beijing, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YMYongchao Ma
Yongchao Ma
NLNanjia Li
Nanjia Li
WLWeibo Liu
Weibo Liu
KMKang Ma
Kang Ma
WZWei Zhao
Wei Zhao
Shisong LiShisong Li
Shisong Li
Although the so-called magnetic geometrical factor, Bl , of a Kibble balance does not appear in the Kibble equations, it offers the precision link between electrical and mechanical quantities and furthers a quasi-quantum traceability path for mass metrology. This feature makes the magnet system, supplying the Bl in Kibble equations, play a core role in Kibble balances. Following the open-hardware idea, we report here on the design, manufacture, assembly, optimization, and finally performance of a compact magnet system for the Tsinghua tabletop Kibble balance. Notably, the magnet system showcased in this study facilitates a straightforward upper levitation of splitting through a streamlined mechanism guide, substantially enhancing the ease of open and close operations. Experimental tests show the realized magnet systems can yield a high Bl value (e.g., 400Tm for a bifilar coil and 800Tm for a single coil with a wire gauge of 0.2 mm) meanwhile a low volume/weight (40 kg) thanks to the uniformity improvement of magnetic profiles. Furthermore, important parameters related to systematic effects, such as the current effect, are checked, aiming for a final mass-realization accuracy at the 10 –8 level.

5 May 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Shisong LiShisong Li
Shisong Li
YMYongchao Ma
Yongchao Ma
KMKang Ma
Kang Ma
WLWeibo Liu
Weibo Liu
NLNanjia Li
Nanjia Li
XYXinjie Yu
Xinjie Yu
With the adoption of the revised International System of Units (SI), the Kibble balance has become a pivotal instrument for mass calibrations against the Planck constant, h. One of the major focuses in the Kibble balance community is prioritizing experiments that achieve both high accuracy and compactness. The Tsinghua tabletop Kibble balance experiment seeks to develop a compact, high-precision, user-friendly, cost-effective, and open-hardware apparatus for mass realization, specifically within the kilogram range. This paper reports on the progress of the Tsinghua tabletop Kibble balance project over the past two years. Various aspects of the Tsinghua tabletop system, including electrical, magnetic, mechanical, and optical components, are summarized. Key achievements, such as the construction and characterization of the magnet system, determination of absolute gravitational acceleration, investigation of a capacitor-sensor-based weighing unit, and development of a high-precision current source, are presented to provide a comprehensive understanding of the experiment’s status.

3 October 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WLWeibo Liu
Weibo Liu
NLNanjia Li
Nanjia Li
YMYongchao Ma
Yongchao Ma
RHRuo Hu
Ruo Hu
SWShuqing Wu
Shuqing Wu
Shisong LiShisong Li
Shisong Li
The Kibble balance requires a measurement of the local gravitational acceleration, g, with a typical relative measurement uncertainty of $10^{-9}$ . In this article, the determination of g for the Tsinghua tabletop Kibble balance is presented. A polynomial fitting method is proposed for referenceless transfers of the absolute gravitational acceleration using relative gravimeters, showing agreement with the value obtained by the tide correction within a few parts in $10^{9}$ . Horizontal gravity gradient (HGG) and vertical gravity gradient (VGG) are extracted by mapping the gravity distribution at different heights. The self-attraction effect of major components in the experiment and some time-varying systematic effects are modeled. The final determination of the gravitational acceleration at the mass position, with an uncertainty of $5.4~\mu $ Gal ( $k=2$ ), is achieved for the Tsinghua tabletop Kibble balance experiment.

8 December 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
NLNanjia Li
Nanjia Li
WLWeibo Liu
Weibo Liu
YMYongchao Ma
Yongchao Ma
WZWei Zhao
Wei Zhao
Songling HuangSongling Huang
Songling Huang
Shisong LiShisong Li
Shisong Li
The Kibble balance realizes the kilogram by linking mechanical and electrical quantities via a magnet system. In an improved BIPM-type magnet design by Tsinghua University, an open/close surface was incorporated, facilitating operation. However, an unavoidable mechanical air gap at the splitting plane introduces asymmetry in the magnetic flux density profile, degrading field uniformity. This study proposes a two-step yoke compensation method to restore symmetry by adjusting the upper outer yoke’s inner radius and the splitting gap height. Finite element simulations show linear relationships between asymmetry and these parameters, enabling predictive compensation. Experimental results confirm that sequential tuning successfully eliminates asymmetry and recovers the designed uniform field range. The method provides an effective solution for enhancing magnetic field quality in openable Kibble balance magnets.

27 February 2026 in Metrologia
Verified
Journal Article
Open access
Shisong LiShisong Li
Shisong Li
NLNanjia Li
Nanjia Li
WLWeibo Liu
Weibo Liu
EQElsayed E E Qupasie
Elsayed E E Qupasie
WZWei Zhao
Wei Zhao
Songling HuangSongling Huang
Songling Huang
Tabletop version Kibble balances are a significant developing trend for mass realizations following the revised International System of Units. A key innovation through the miniaturization of the Kibble balance from a large-scale instrument into a tabletop device is making the quantum-based realization of mass accessible to a wider range of calibration laboratories and industries. This paper presents a tabletop Kibble balance design at Tsinghua University targeting E2-accuracy class mass calibrations from 1 g to 1 kg. For calibrating a mass of 1 kg, for instance, the required relative standard measurement uncertainty must be below 0.27 ppm to meet E2-accuracy class. Major components and features of the proposed system are discussed. A novel method of multi-harmonic excitation is proposed to improve the coil-motion linearity during velocity measurement. We show that injecting odd-order harmonics into the motion-driving current can significantly improve the uniformity of the coil’s moving velocity, while the second-order component can address the asymmetry between upward and downward movements. This achieves a flat velocity Δ v / v < 5 % over 60% of the motion cycle.