Kang Ma

Kang Ma

Auto-generated profile, based on publicly available information

Kang Ma

Department of Electrical Engineering, Tsinghua University, Beijing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
KMKang Ma
Kang Ma
HLHuaqi Liu
Huaqi Liu
QWQiang Wang
Qiang Wang
SWShenghui Wang
Shenghui Wang
FLFangcheng Lv
Fangcheng Lv
Gas insulated transmission lines (GIL) have a wide application prospect in special occasions such as cross terrain power transmission. Metal particle contamination is an important reason for the low insulation performance of GIL. In order to better suppress metal particle contamination, it is necessary to master the motion characteristics of metal particles. Based on that, this paper took the metal particle dust (MPD), which is common in engineering, as the research object. The boundary element method (BEM) was introduced, and the boundary integral equations (BIE) of multimedia domain Poisson equation in three-dimension were given. The electric field distribution considering charged particles was obtained. Then the motion model of MPD was established. Combined with experiments, the movement and distribution characteristics of MPD in direct-current (DC) GIL was studied. The results show that the randomness of MPD movement in DC GIL is strong, and near the ground, MPD presents a ‘sandstorm’ movement. Secondly, due to the influence of charged metal particles on electric field distribution, the collision between metal particles, and the randomness of the collision between metal particles and wall, the range of MPD’s motion in the axial direction of GIL chamber is wide, which increases the probability of MPD adhering to the insulator. And the adhesion of MPD is more obvious on the convex surface of the insulator near the high voltage electrode. The above research results can be used to guide the suppression of metal particle contamination in DC GIL.

26 December 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YMYongchao Ma
Yongchao Ma
NLNanjia Li
Nanjia Li
WLWeibo Liu
Weibo Liu
KMKang Ma
Kang Ma
WZWei Zhao
Wei Zhao
Shisong LiShisong Li
Shisong Li
Although the so-called magnetic geometrical factor, Bl , of a Kibble balance does not appear in the Kibble equations, it offers the precision link between electrical and mechanical quantities and furthers a quasi-quantum traceability path for mass metrology. This feature makes the magnet system, supplying the Bl in Kibble equations, play a core role in Kibble balances. Following the open-hardware idea, we report here on the design, manufacture, assembly, optimization, and finally performance of a compact magnet system for the Tsinghua tabletop Kibble balance. Notably, the magnet system showcased in this study facilitates a straightforward upper levitation of splitting through a streamlined mechanism guide, substantially enhancing the ease of open and close operations. Experimental tests show the realized magnet systems can yield a high Bl value (e.g., 400Tm for a bifilar coil and 800Tm for a single coil with a wire gauge of 0.2 mm) meanwhile a low volume/weight (40 kg) thanks to the uniformity improvement of magnetic profiles. Furthermore, important parameters related to systematic effects, such as the current effect, are checked, aiming for a final mass-realization accuracy at the 10 –8 level.

5 May 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Shisong LiShisong Li
Shisong Li
YMYongchao Ma
Yongchao Ma
KMKang Ma
Kang Ma
WLWeibo Liu
Weibo Liu
NLNanjia Li
Nanjia Li
XYXinjie Yu
Xinjie Yu
With the adoption of the revised International System of Units (SI), the Kibble balance has become a pivotal instrument for mass calibrations against the Planck constant, h. One of the major focuses in the Kibble balance community is prioritizing experiments that achieve both high accuracy and compactness. The Tsinghua tabletop Kibble balance experiment seeks to develop a compact, high-precision, user-friendly, cost-effective, and open-hardware apparatus for mass realization, specifically within the kilogram range. This paper reports on the progress of the Tsinghua tabletop Kibble balance project over the past two years. Various aspects of the Tsinghua tabletop system, including electrical, magnetic, mechanical, and optical components, are summarized. Key achievements, such as the construction and characterization of the magnet system, determination of absolute gravitational acceleration, investigation of a capacitor-sensor-based weighing unit, and development of a high-precision current source, are presented to provide a comprehensive understanding of the experiment’s status.

16 October 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
KMKang Ma
Kang Ma
XLXiaohu Liu
Xiaohu Liu
WZWei Zhao
Wei Zhao
Songling HuangSongling Huang
Songling Huang
Shisong LiShisong Li
Shisong Li
A high-precision current source, capable of supporting weighing measurements with a relative uncertainty at the 10 -9 level, is essential for Kibble balance experiments. However, most current sources utilized in Kibble balances to date are homemade and not commercially available. In this paper, we introduce a digital-feedback, two-stage current source designed for the Tsinghua tabletop Kibble balance, relying solely on commercially available sources and voltmeters. A high-resolution, small-range current source is employed to digitally compensate for current output fluctuations from a large-range current source. Experimental tests show the proposal can offer an easy realization of a current source with nA/A stability to support Kibble balance measurements.

18 April 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
FLFangcheng Lv
Fangcheng Lv
KMKang Ma
Kang Ma
HGHui Geng
Hui Geng
SWShenghui Wang
Shenghui Wang
ZLZhongwei Li
Zhongwei Li
QZQizhe Zhang
Qizhe Zhang
We mainly study the influence of surface charge on the movement and distribution characteristics of metal particle dust (MPD) in DC GIS/GIL. Based on the improved boundary element algorithm, we establish the movement model of MPD. Combined with experiments, we obtained the distribution characteristics of MPD. The research results show that under negative voltage, the metal particle contamination is more serious at convex side of the spacer. Homopolar surface charge enhances the adhesion of MPD near the spacer, but it also enhances the repulsion between spacer and MPD in chamber. Heteropolar surface charge weakens the adhesion of MPD near the spacer, but it also weakens the repulsion between spacer and MPD in chamber. Therefore, we suggest that surface regulation should be adopted to make the spacer surface accumulate homopolar surface charge. Meanwhile particle traps should be installed near the spacer and in middle of the chamber to achieve more comprehensive metal particle suppression.

19 January 2024 in High Voltage
Verified
Journal Article
Open access
KMKang Ma
Kang Ma
FLFangcheng Lv
Fangcheng Lv
SWShenghui Wang
Shenghui Wang
HLHuaqi Liu
Huaqi Liu
LWLihong Wang
Lihong Wang
Accurate surface charge inversion can guide the research on surface modification of insulators in GIS/GIL. The current inversion algorithms have disadvantages of high computational cost and low accuracy. Based on that, the integral equation method (IEM) is proposed to calculate the transformation matrix. Compared with the traditional analytical method (AM), IEM has a simple calculation process. The calculation speed of IEM is much faster than that of AM. To suppress the numerical divergence in IEM, the Tikhonov regularisation method is introduced and Tikhonov‐IEM is proposed. For square insulators, compared to IEM, the peak‐mean square error (PMSE) is reduced by about 40 percent. However, Tikhonov‐IEM is not suitable for basin insulators. Therefore, the least square method (LSM) is introduced and the LSM‐IEM is proposed. For basin insulators, compared to IEM, the PMSE is reduced by about 30 percent. Finally, the accuracy of the algorithms is verified by physical tests.