Thiago Bulhões da Silva Costa

Thiago Bulhões da Silva Costa

Auto-generated profile, based on publicly available information

Thiago Bulhões da Silva Costa

Universidade Federal do ABC

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2015 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
SCSarah N. Carvalho
Sarah N. Carvalho
TCThiago B.S. Costa
Thiago B.S. Costa
LULuisa F.S. Uribe
Luisa F.S. Uribe
DSDiogo Coutinho Soriano
Diogo Coutinho Soriano
GYGlauco F.G. Yared
Glauco F.G. Yared
RARomis Attux
Romis Attux

25 October 2022 in Expert Systems with Applications
Verified
Journal Article
Closed access
PPPatrick Oliveira de Paula
Patrick Oliveira de Paula
TCThiago Bulhões da Silva Costa
Thiago Bulhões da Silva Costa
RARomis Ribeiro de Faissol Attux
Romis Ribeiro de Faissol Attux
DFDenis Gustavo Fantinato
Denis Gustavo Fantinato

1 January 2018 in Computational Intelligence and Neuroscience
Verified
Journal Article
Open access
HLHarlei Miguel de Arruda Leite
Harlei Miguel de Arruda Leite
SCSarah Negreiros de Carvalho
Sarah Negreiros de Carvalho
TCThiago Bulhões da Silva Costa
Thiago Bulhões da Silva Costa
RARomis Attux
Romis Attux
HHHeiko Horst Hornung
Heiko Horst Hornung
DADalton Soares Arantes
Dalton Soares Arantes
This paper presents a systematic analysis of a game controlled by a Brain-Computer Interface (BCI) based on Steady-State Visually Evoked Potentials (SSVEP). The objective is to understand BCI systems from the Human-Computer Interface (HCI) point of view, by observing how the users interact with the game and evaluating how the interface elements influence the system performance. The interactions of 30 volunteers with our computer game, named “Get Coins,” through a BCI based on SSVEP, have generated a database of brain signals and the corresponding responses to a questionnaire about various perceptual parameters, such as visual stimulation, acoustic feedback, background music, visual contrast, and visual fatigue. Each one of the volunteers played one match using the keyboard and four matches using the BCI, for comparison. In all matches using the BCI, the volunteers achieved the goals of the game. Eight of them achieved a perfect score in at least one of the four matches, showing the feasibility of the direct communication between the brain and the computer. Despite this successful experiment, adaptations and improvements should be implemented to make this innovative technology accessible to the end user.

13 April 2022 in Journal of Medical Internet Research
Verified
Journal Article
Open access
TCThiago Bulhões da Silva Costa
Thiago Bulhões da Silva Costa
LSLucas Shinoda
Lucas Shinoda
RMRamon Alfredo Moreno
Ramon Alfredo Moreno
JKJose Krieger
Jose Krieger
MGMarco Antonio Gutierrez
Marco Antonio Gutierrez
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: The importance of blockchain-based architectures for personal health record (PHR) lies in the fact that they are thought and developed to allow patients to control and at least partly collect their health data. Ideally, these systems should provide the full control of such data for the respective owner. In spite of this importance, most of the works focus more on describing how blockchain models can be used in a PHR scenario than whether these models are in fact feasible and robust enough to support a large number of users. Objective: Toward a consistent, reproducible and comparable PHR system, we build a novel ledger-oriented architecture out of a permissioned distributed network, providing patients with a manner to securely collect, store, share and manage their health data. We also emphasize the importance of suitable ledgers and smart contracts to operate the blockchain network as well as discuss the necessity of standardizing evaluation metrics to compare related (net)works. Methods: We adopted the Hyperledger Fabric platform to implement our blockchain-based architecture design and the Hyperledger Caliper framework to provide a detailed assessment of our system: firstly, under workload, ranging from 100 to 2,500 simultaneous record submissions, and, secondly, increasing the network size, from 3 to 13 peers. In both experiments, we used throughput and average latency as primary metrics. We also create a health database, a cryptographic unit and a server to complement the blockchain network. Results: With a 3-peer network, smart contracts that write on the ledger have throughputs, measured in transactions per second (tps), in an order of magnitude close to 102 tps while those contracts that only read have rates close to 103 tps. Smart contracts that write also have latencies, measured in seconds (s), in an order of magnitude close to 101 s while that only read have delays close to 100 s. In particular, smart contracts that retrieve, list and view history have throughputs varying, respectively, from 1,100 to 1,300 tps, 650 to 750 tps and 850 to 950 tps, impacting the overall system response if they are equally requested under the same workload. Varying the network size and applying an equal fixed load, in turn, writing throughputs go from 102 to 101 tps and latencies go from 101 to 102 s while reading ones maintain similar values. Conclusions: To the best of our knowledge, we are the first to evaluate, using Hyperledger Caliper, the performance of a PHR blockchain architecture and also the first to evaluate each smart contract separately. Nevertheless, blockchain systems achieve performances far below the traditional distributed databases achieve, indicating the assessment of blockchain solutions for PHR is a major concern to be addressed before putting them into a real production.

9 June 2023 in IEEE Access
Verified
Journal Article
Open access
TCThiago Bulhões Da Silva Costa
Thiago Bulhões Da Silva Costa
FDFelipe Meneguitti Dias
Felipe Meneguitti Dias
DCDiego Armando Cardona Cardenas
Diego Armando Cardona Cardenas
MTMarcelo Arruda Fiuza De Toledo
Marcelo Arruda Fiuza De Toledo
DLDaniel Mário De Lima
Daniel Mário De Lima
MGMarco Antonio Gutierrez
Marco Antonio Gutierrez
Cardiovascular diseases are the leading causes of death, and blood pressure (BP) monitoring is essential for prevention, diagnosis, assessment, and treatment. Photoplethysmography (PPG) is a low-cost opto-electronic technique for BP measurement that allows the acquisition of a modulated light signal highly correlated with BP. There are several reports of methods to estimate BP from PPG with impressive results; in this study, we demonstrate that the previous results are excessively optimistic because of their train/test split configuration. To manage this limitation, we considered intra- and inter-subject data arrangements and demonstrated how they affect the results of feature-based BP estimation algorithms (i.e., XGBoost, LightGBM, and CatBoost) and signal-based algorithms (i.e., Residual U-Net, ResNet-18, and ResNet-LSTM). Inter-subject configuration performance is inferior to intra-subject configuration performance, regardless of the model. We also showed that, using only demographic attributes (i.e., age, sex, weight, and subject index number), a regression model achieved results comparable to those obtained in an intra-subject scenario.Although limited to a public clinical database, our findings suggest that algorithms that use an intra-subject setting without a calibration strategy may be learning to identify patients and not predict BP.

1 October 2019 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
LULuisa Fernanda Suarez Uribe
Luisa Fernanda Suarez Uribe
CFCarlos Alberto Stefano Filho
Carlos Alberto Stefano Filho
VOVinicius Alves de Oliveira
Vinicius Alves de Oliveira
TCThiago Bulhões da Silva Costa
Thiago Bulhões da Silva Costa
PRPaula Gabrielly Rodrigues
Paula Gabrielly Rodrigues
RARomis Attux
Romis Attux
Objective. This work aims to present a deeper investigation of the performance achieved by a motor imagery (MI) EEG-based brain-computer interface (BCI) using functional connectivity (FC) measures as features. The analysis is performed for two different datasets and analytical setups, including an information-theoretic based FC estimator (correntropy). Approach. In the first setup, using data acquired by our group, correntropy was compared to Pearson and Spearman correlations for FC estimation followed by graph-based feature extraction and two different classification strategies - linear discriminant analysis (LDA) and extreme learning machines (ELMs) - coupled with a wrapper for feature selection in the mu (7 - 13 Hz) and beta (13 - 30 Hz) frequency bands. In the second setup, the BCI competition IV dataset 2a was considered for a broader comparison. Main results. For our own database the correntropy / degree centrality / ELM approach resulted in the most solid framework, with overall classification error as low as 5\%. When using the BCI competition dataset, our best result provided a performance comparable to those of the top three competitors. Significance. Correntropy was shown to be the best FC estimator in all analyzed situations in the first experimental setup, capturing the signal temporal behavior and being less sensitive to outliers. The second experimental setup showed that the inclusion of different frequency bands can bring more information and improve the classification performance. Finally, our results pointed towards the importance of the joint use of different graph measures for the classification.