Diego Armando Cardona Cardenas

Diego Armando Cardona Cardenas

Auto-generated profile, based on publicly available information

Diego Armando Cardona Cardenas

Clinics Hospital University of São Paulo Medical School

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2025 in Physiological Measurement
Verified
Journal Article
Closed access
FDFelipe Meneguitti Dias
Felipe Meneguitti Dias
DCDiego A C Cardenas
Diego A C Cardenas
MTMarcelo A F Toledo
Marcelo A F Toledo
FOFilipe A C Oliveira
Filipe A C Oliveira
EREstela Ribeiro
Estela Ribeiro
MGMarco Antonio Gutierrez
Marco Antonio Gutierrez
Objetive. Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) emerges as a promising approach for continuous BP monitoring. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, requiring a comprehensive evaluation of their efficacy. This paper aims to provide the potentials and limitations regarding BP estimation from single-site PPG signals. Approach. We developed a calibration-based Siamese ResNet model for BP estimation. We compared the use of normalized PPG (N-PPG) against the normalized invasive arterial BP (N-IABP) signals as input. N-IABP signals, while not directly presenting systolic (SBP) and diastolic (DBP) BP values, are expected to offer more precise estimations than PPG since it is a direct pressure sensor inside the body. Thus, if N-IABP poses challenges in BP estimation, predicting BP from PPG signals might be even more challenging. Main results. Our evaluation, conducted using the AAMI and BHS standards on the VitalDB dataset, revealed that inference using N-IABP signals meet with AAMI standards for both SBP and DBP, with errors of 1.29 ± 6.33 mmHg for systolic pressure and 1.17 ± 5.78 for diastolic pressure. In contrast, N-PPG based inference exhibited inferior performance than N-IABP, presenting 1.49 ± 11.82 mmHg and 0.89 ± 7.27 mmHg for systolic and diastolic pressure respectively in their best setup. Significance. Our findings establish a critical benchmark for PPG performance, providing realistic expectations for its BP estimation capabilities. We concluded that while PPG signals contain BP-correlated information, they may not suffice for accurate prediction.

9 June 2023 in IEEE Access
Verified
Journal Article
Open access
TCThiago Bulhões Da Silva Costa
Thiago Bulhões Da Silva Costa
FDFelipe Meneguitti Dias
Felipe Meneguitti Dias
DCDiego Armando Cardona Cardenas
Diego Armando Cardona Cardenas
MTMarcelo Arruda Fiuza De Toledo
Marcelo Arruda Fiuza De Toledo
DLDaniel Mário De Lima
Daniel Mário De Lima
MGMarco Antonio Gutierrez
Marco Antonio Gutierrez
Cardiovascular diseases are the leading causes of death, and blood pressure (BP) monitoring is essential for prevention, diagnosis, assessment, and treatment. Photoplethysmography (PPG) is a low-cost opto-electronic technique for BP measurement that allows the acquisition of a modulated light signal highly correlated with BP. There are several reports of methods to estimate BP from PPG with impressive results; in this study, we demonstrate that the previous results are excessively optimistic because of their train/test split configuration. To manage this limitation, we considered intra- and inter-subject data arrangements and demonstrated how they affect the results of feature-based BP estimation algorithms (i.e., XGBoost, LightGBM, and CatBoost) and signal-based algorithms (i.e., Residual U-Net, ResNet-18, and ResNet-LSTM). Inter-subject configuration performance is inferior to intra-subject configuration performance, regardless of the model. We also showed that, using only demographic attributes (i.e., age, sex, weight, and subject index number), a regression model achieved results comparable to those obtained in an intra-subject scenario.Although limited to a public clinical database, our findings suggest that algorithms that use an intra-subject setting without a calibration strategy may be learning to identify patients and not predict BP.

25 June 2024 in European Heart Journal - Digital Health
Verified
Journal Article
Open access
PDF file
EREstela Ribeiro
Estela Ribeiro
DCDiego A C Cardenas
Diego A C Cardenas
FDFelipe Meneguitti Dias
Felipe Meneguitti Dias
JKJose Krieger
Jose Krieger
MGMarco Antonio Gutierrez
Marco Antonio Gutierrez
Aims: Aortic elongation can result from age-related changes, congenital factors, aneurysms, or conditions affecting blood vessel elasticity. It is associated with cardiovascular diseases and severe complications like aortic aneurysms and dissection. We assess qualitatively and quantitatively explainable methods to understand the decisions of a deep learning model for detecting aortic elongation using chest X-ray (CXR) images. Methods and results: In this study, we evaluated the performance of deep learning models (DenseNet and EfficientNet) for detecting aortic elongation using transfer learning and fine-tuning techniques with CXR images as input. EfficientNet achieved higher accuracy (86.7% ± 2.1), precision (82.7% ± 2.7), specificity (89.4% ± 1.7), F1 score (82.5% ± 2.9), and area under the receiver operating characteristic (92.7% ± 0.6) but lower sensitivity (82.3% ± 3.2) compared with DenseNet. To gain insights into the decision-making process of these models, we employed gradient-weighted class activation mapping and local interpretable model-agnostic explanations explainability methods, which enabled us to identify the expected location of aortic elongation in CXR images. Additionally, we used the pixel-flipping method to quantitatively assess the model interpretations, providing valuable insights into model behaviour. Conclusion: Our study presents a comprehensive strategy for analysing CXR images by integrating aortic elongation detection models with explainable artificial intelligence techniques. By enhancing the interpretability and understanding of the models’ decisions, this approach holds promise for aiding clinicians in timely and accurate diagnosis, potentially improving patient outcomes in clinical practice.

31 August 2023 in medRxiv
Verified
Preprint
Open access
PDF file
EREstela Ribeiro
Estela Ribeiro
DCDiego Armando Cardona Cardenas
Diego Armando Cardona Cardenas
FDFelipe Meneguitti Dias
Felipe Meneguitti Dias
JKJose Krieger
Jose Krieger
MGMarco Antonio Gutierrez
Marco Antonio Gutierrez
Aim: Aortic Elongation can result from age-related changes, congenital factors, aneurysms, or conditions affecting blood vessel elasticity. It is associated with cardiovascular diseases and severe complications like aortic aneurysms and dissection. We aim to assess qualitatively and quantitatively explainable methods in order to understand the decisions of a deep learning model for Aortic Elongation detection with Chest X-Ray (CXR) images. Methods and Results: In this work, we evaluated the performance of deep learning models (DenseNet and EfficientNet) for aortic elongation detection based on transfer learning and fine-tunning techniques using CXR as input. DenseNet achieved higher accuracy (84.7% ± 0.7), precision (75.6% ± 1.3), sensitivity (88.7% ± 2.7), specificity (82.3% ± 1.6), F1-score (81.6% ± 1.0), and AUROC (93.1% ± 0.4) than EfficientNet. To gain insights into the decision-making process of the deep learning models, we employed Grad-CAM and LIME explainability methods. Through these techniques, we were able to successfully identify the expected location of aortic elongation in the x-ray images. Moreover, we used the pixel-flipping method to assess quantitatively the interpretations providing valuable insights into models behavior. Conclusion: Our study presents a comprehensive strategy for analyzing CXR by integrating Aortic Elongation detection models with explainable methods. By incorporating explainable AI techniques, we enhanced the interpretability and understanding of the models’ decisions. This approach holds promise for aiding clinicians in timely and accurate diagnosis, potentially improving patient outcomes in clinical practice.

16 May 2019
Verified
Book Chapter
Closed access
PDF file
DCDiego Armando Cardona Cardenas
Diego Armando Cardona Cardenas
SFSergio Shiguemi Furuie
Sergio Shiguemi Furuie

15 January 2022 in Revista da Sociedade de Cardiologia do Estado de São Paulo
Verified
Journal Article
Closed access
MGMarco Antonio Gutierrez
Marco Antonio Gutierrez
DCDiego Armando Cardona Cardenas
Diego Armando Cardona Cardenas
KMKarem Daiane Marcomin
Karem Daiane Marcomin
ATAgma Juci Machado Traina
Agma Juci Machado Traina
RMRamon Alfredo Moreno
Ramon Alfredo Moreno
JKJose Krieger
Jose Krieger
Avanços recentes na área de inteligência artificial, especialmente em aprendizagem profunda, levaram a um desempenho promissor em muitas tarefas de análise e proces- samento de imagens médicas. Como exame radiológico mais comumente realizado, a radiografia de tórax é uma modalidade particularmente importante para a qual uma variedade de métodos e aplicações tem sido proposta. Paralelamente, com a crescente disponibilização de vários conjuntos de dados de raios-X de tórax (CXR), muitos deles, com dezenas de milhares de exames e publicamente disponíveis nos últimos anos, motivaram o interesse na pesquisa e o desenvolvimento nessa área. Neste artigo, apresentamos uma breve revisão de alguns dos estudos recentes que envolvem a aprendizagem profunda em radiografia de tórax, bem como os principais conceitos que envolvem redes neurais artificiais e a capacidade dessas redes nas tarefas de classificação, segmentação e localização de lesões a partir das informações presentes na imagem.