Renata de Faria Santos

Renata de Faria Santos

Auto-generated profile, based on publicly available information

Renata de Faria Santos

Universidade de São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Dental Press Journal of Orthodontics
Verified
Journal Article
Open access
RSRenata de Faria Santos
Renata de Faria Santos
BSBruno Fernandes de Oliveira Santos
Bruno Fernandes de Oliveira Santos
VFVictor Miranda Fernandes
Victor Miranda Fernandes
LCLuciana Duarte Caldas
Luciana Duarte Caldas
TBTaiana de Oliveira Baldo
Taiana de Oliveira Baldo
GDGladys Cristina Dominguez
Gladys Cristina Dominguez
Objective: The objectives of the present study were to develop a method for longitudinally measuring tooth rotation, inclination and angulation on digital models, and to test the method validity and reliability. Methods: The initial and final planned models of 14 patients treated with Invisalign® (386 teeth) were exported from ClinCheck®. The rotation, inclination and angulation values were assessed for the incisors, canines, premolars and molars, in both models, using trigonometry. An application was developed in Python 2.7 to automate the measurements. The ∆planned (variation in the position between the initial and final planned models) was obtained for each tooth and each type of movement. To test the validity, the degree of agreement between the ∆planned and the values available in the Invisalign® Table of Movements was assessed using the Intraclass Correlation Coefficient (ICC) and Bland-Altman analysis. For intra and inter-rater reliabilities, the ∆planned was obtained again. Results: Excellent ICCs (> 0.9) and limits of agreement with narrow and clinically acceptable discrepancies were obtained for the rotation of all teeth (except maxillary canines, which had broader limits: -3.47 - 5.43) and for the inclination of premolars and molars. The inclination of anterior teeth and angulation of all teeth had ICCs and limits that were not indicative of great agreement. The reliability was high for the three movements (discrepancy <2°). Conclusions: The method developed is reliable and suitable for longitudinally measuring inclination (posterior teeth) and rotation (except maxillary canines). It has limited value for the other movements measurements.

19 October 2022 in Revista da Faculdade de Odontologia de Porto Alegre
Verified
Journal Article
Open access
PDF file
ABAíla Andrade Batista
Aíla Andrade Batista
GGGabriela Mancia De Gutierrez
Gabriela Mancia De Gutierrez
RSRenata de Faria Santos
Renata de Faria Santos
Introdução: O Transtorno do Espectro Autista (TEA) é um distúrbio de desenvolvimento que interfere nas áreas de interação social e comportamental, podendo ser classificado em níveis leve, moderado e severo. Objetivo: Realizar uma revisão de literatura para identificar os sinais presentes em pacientes com esse transtorno, e assim auxiliar os cirurgiões dentistas, principalmente o odontopediatra, no diagnóstico precoce. Revisão de literatura: As primeiras manifestações do TEA aparecem antes dos 36 meses de idade. Um dos sinais clínicos relacionados à interação social são crianças que preferem ficar sozinhas, não participando de brincadeiras. Costumam ser observados sinais de comportamentos repetitivos e interesses restritos, que podem dificultar o convívio social. Atrasos na fala são, frequentemente, o principal sinal observado pelos pais. Alguns questionários de rastreamento de TEA podem ser aplicados pelos profissionais da saúde. Discussão: O cirurgião-dentista, especialmente o odontopediatra, deve estar atento ao desenvolvimento do paciente infantil, verificando a presença de atraso na fala, característica importante do espectro, bem como de desvios de comportamento incompatíveis com a idade ou procedimento odontológico. Na presença de algum sinal do espectro o profissional não deve hesitar em encaminhar para outros profissionais para melhor avaliação. Conclusão: O conhecimento desses sinais por parte dos profissionais de saúde, em especial o odontopediatra, é de fundamental importância para auxiliar no diagnóstico precoce, a fim de minimizar os sintomas e contribuir para o desenvolvimento e integração da criança com TEA na sociedade.

1 January 2024 in Dental Press Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
RMRaquel Bueno Medeiros
Raquel Bueno Medeiros
RSRenata Faria Santos
Renata Faria Santos
JMJose Augusto Mendes-Miguel
Jose Augusto Mendes-Miguel
EREduardo Kant Colunga Rothier
Eduardo Kant Colunga Rothier
FMFausto Mendes
Fausto Mendes
GDGladys Cristina Dominguez
Gladys Cristina Dominguez
Objective: The purpose of this retrospective study was to compare accuracy of arch expansion using two different thermoplastic materials in Invisalign aligners: EX30® (Polyethylene Terephthalate Glycol, or PETG) and SmartTrack® (polyurethane). Methods: The study sample comprised 65 adult patients consecutively treated with Invisalign from two private practices: group 1 - treated with EX30® (358 teeth) and group 2 - treated with SmartTrack® (888 teeth). Six hundred and twenty-three measurements were assessed in three digital models throughout treatment: model 1 - initial, model 2 - predicted tooth position, and model 3 - achieved position. Sixteen reference points per arch were marked and, after best alignment, 2 points per tooth were copied from one digital model to another. Linear values of both arches were measured for canines, premolars, and first molars: on lingual gingival margins and cusp tips of every tooth. Comparisons were performed by Wilcoxon and Mann-Whitney test. Results: Both termoplastic materials presented significant differences between predicted and achieved values for all measurements, except for the lower molar cusp tip in the SmartTrack® group. There is no statistical difference in the accuracy of transverse expansion between these two materials. Overall accuracy for EX30® aligners in maxilla and mandible were found to be 37 and 38%, respectively; and Smarttrack® presented an overall accuracy of 56.62% in the maxilla and 68.72% in the mandible. Conclusions: It is not possible to affirm one material expands better than the other. Further controlled clinical studies should be conducted comparing SmartTrack® and EX30® under similar conditions.

1 January 2024 in Dental Press Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
RMRaquel Bueno Medeiros
Raquel Bueno Medeiros
RSRenata Faria Santos
Renata Faria Santos
JMJose Augusto Mendes-Miguel
Jose Augusto Mendes-Miguel
EREduardo Kant Colunga Rothier
Eduardo Kant Colunga Rothier
FMFausto Mendes
Fausto Mendes
GDGladys Cristina Dominguez
Gladys Cristina Dominguez
Objective: This retrospective study aimed to assess the predictability of Invisalign® aligners regarding rotational, mesio-distal and buccal-lingual tip movements. Methods: Two materials were included in the analysis - EX30, used until 2013; and SmartTrack, in current use. The study comprised 56 adult patients treated with Invisalign Comprehensive. Data sample were assessed on three sets of digital models; model 1 - initial, model 2 - predicted, and model 3 - achieved. Sixty reference points were marked in each dental arch, and two reference planes assisted the superimposition. The degree of rotation, mesio-distal and buccal-lingual tip was obtained via trigonometric calculations, through a previously published validated method. The accuracy of outcomes was compared according to the types of tooth movement and teeth groups,and the influence of predetermined variables on movement accuracy was also investigated. Results: Rotation and mesio-distal tip did not present any significant difference when comparing EX30 and SmartTrack groups. Only buccal-lingual tip presented a significant difference, incisor and canine groups treated with EX30 aligners presented an increase in accuracy (p= 0.007 and p = 0.007, respectively). For each additional degree planned for rotation movements, there was an increase of 0.35° in the discrepancy, and an increase of 0.40° and 0.41° for mesio-distal and buccal-lingual tip, respectively. EX30 and SmartTrack discrepancies were compared by multilevel linear regression. Conclusion: EX30 aligners reached higher accuracy for buccal-lingual tip in anterior teeth. However, for rotation and mesio-distal tip, SmartTrack and EX30 are similarly accurate. The total amount of planned movement has a significant impact on accuracy rates, with a decrease in accuracy for every additional degree.

10 April 2022 in AJO-DO Clinical Companion
Verified
Journal Article
Closed access
LCLuciana Duarte Caldas
Luciana Duarte Caldas
RSRenata de Faria Santos
Renata de Faria Santos
ANAnna Paula Nigri
Anna Paula Nigri
ESEduardo Franzotti Sant'ANna
Eduardo Franzotti Sant'ANna