The present study aimed to analyze the effect of LED phototherapy on the presence of hyalinization and root resorption during orthodontic tooth movement (OTM) in rats and to measure the amount of tooth movement. Eighty rats were allocated into two groups: LED and control (CON), where the LED rats were irradiated with infrared LED (850 nm, 30 mW) for 5 min during the first five days of OTM and where controls were not irradiated. Both groups were subdivided into four subgroups (n=10) according to the date of euthanasia (4, 7, 14 and 21 days). Five out of ten LED21 and five of ten CON21 rats were submitted to micro-computed tomography (μCT); μCT scans were taken on days 0, 7, 14 and 21. For histological study, maxillae were processed to light microscopy using Hematoxylin-Eosin (HE) and Tartrate-Resistant Acid Phosphatase (TRAP) histochemistry. The amount of tooth movement did not differ between LED and CON. Hyalinization was observed at the pressure areas in both groups, and it did not show a statistically significant difference between the groups. Root resorption was also observed in both groups after 7 days and it did not represent any differences between the two groups. LED phototherapy was not able to increase the amount of OTM. Similar characteristics of hyalinization and root resorption were observed in both groups.
10 August 2022 in Orthodontics & Craniofacial Research
Objective: The objectives of the present study were to develop a method for longitudinally measuring tooth rotation, inclination and angulation on digital models, and to test the method validity and reliability. Methods: The initial and final planned models of 14 patients treated with Invisalign® (386 teeth) were exported from ClinCheck®. The rotation, inclination and angulation values were assessed for the incisors, canines, premolars and molars, in both models, using trigonometry. An application was developed in Python 2.7 to automate the measurements. The ∆planned (variation in the position between the initial and final planned models) was obtained for each tooth and each type of movement. To test the validity, the degree of agreement between the ∆planned and the values available in the Invisalign® Table of Movements was assessed using the Intraclass Correlation Coefficient (ICC) and Bland-Altman analysis. For intra and inter-rater reliabilities, the ∆planned was obtained again. Results: Excellent ICCs (> 0.9) and limits of agreement with narrow and clinically acceptable discrepancies were obtained for the rotation of all teeth (except maxillary canines, which had broader limits: -3.47 - 5.43) and for the inclination of premolars and molars. The inclination of anterior teeth and angulation of all teeth had ICCs and limits that were not indicative of great agreement. The reliability was high for the three movements (discrepancy <2°). Conclusions: The method developed is reliable and suitable for longitudinally measuring inclination (posterior teeth) and rotation (except maxillary canines). It has limited value for the other movements measurements.
1 January 2024 in Dental Press Journal of Orthodontics
Objective: The purpose of this retrospective study was to compare accuracy of arch expansion using two different thermoplastic materials in Invisalign aligners: EX30® (Polyethylene Terephthalate Glycol, or PETG) and SmartTrack® (polyurethane). Methods: The study sample comprised 65 adult patients consecutively treated with Invisalign from two private practices: group 1 - treated with EX30® (358 teeth) and group 2 - treated with SmartTrack® (888 teeth). Six hundred and twenty-three measurements were assessed in three digital models throughout treatment: model 1 - initial, model 2 - predicted tooth position, and model 3 - achieved position. Sixteen reference points per arch were marked and, after best alignment, 2 points per tooth were copied from one digital model to another. Linear values of both arches were measured for canines, premolars, and first molars: on lingual gingival margins and cusp tips of every tooth. Comparisons were performed by Wilcoxon and Mann-Whitney test. Results: Both termoplastic materials presented significant differences between predicted and achieved values for all measurements, except for the lower molar cusp tip in the SmartTrack® group. There is no statistical difference in the accuracy of transverse expansion between these two materials. Overall accuracy for EX30® aligners in maxilla and mandible were found to be 37 and 38%, respectively; and Smarttrack® presented an overall accuracy of 56.62% in the maxilla and 68.72% in the mandible. Conclusions: It is not possible to affirm one material expands better than the other. Further controlled clinical studies should be conducted comparing SmartTrack® and EX30® under similar conditions.