1 September 2012 in Chinese Physics C
A readout system for X-ray CCDs based on an improved architecture is presented; by optimizing several critical circuit blocks along the analog signal chain, the conflict between the readout speed and readout noise is greatly alleviated. Using CCD47-10 as its target CCD, the readout system has achieved 8.6e− readout noise and 142 eV FWHM at 5.9 keV Mn Kα under a pixel rate of 80 kHz. Also its performance of imaging has been investigated.
1 June 2017 in Electronics Letters
Correlated double sampling (CDS) circuits are essential to process the X‐ray charge‐coupled devices (CCDs) that have been used in the modern X‐ray astronomical field. A novel CDS circuit is presented. The innovation of the circuit is that it greatly improves the noise and linearity performances through moving the clamping switch out of the signal path as well as omitting the sampling switch which eliminates the nonlinearity and thermal noise introduced by these switches. Also, a baseline adjustment (BLA) circuit is incorporated so as to make efficient use of the dynamic range of the ADC, making the CDS circuit flexible to interface the CCD operating under a wide range of temperatures. A prototype application‐specific integrated circuit (ASIC) is designed with GlobalFoundries 0.35 μm CMOS process and the experimental results show that with pixel rate varying from 100 kHz to 1 MHz, the integral nonlinearity and equivalent input noise performances are quite consistent, which are better than 27 ppm and 23 μV, respectively, within a dynamic range of 1.5 V pp . The effective adjustment range of the BLA is at least 2 V, and the power consumption for a single CDS core is 10 mW approximately from a 3.3 V power supply.
7 May 2018 in IEEE Transactions on Nuclear Science
Design, analysis and experimental results of a four-channel correlated double sampling (CDS) ASIC, named CDS4C, are presented. It aims to interface a type of multi-readout swept charge device (SCD) for applications in the fields of X-ray spectroscopy, imaging as well as timing. Compared with the conventional CDS architectures based on clamping technique, the innovation of the CDS4C ASIC is that it not only moves the clamping switch out of the signal path but also omits the sampling switch, eliminating the nonlinearity and thermal noise introduced by these switches. Besides, it is implemented in a fully differential architecture which suppresses the second-order harmonic distortion and common-mode (CM) interferences, improving the linearity further more. A theoretical noise analysis which takes into account the limited bandwidth of the opamp highly coincides with the simulation results. A prototype of the CDS4C ASIC is fabricated with GlobalFoundries 0.35 μm CMOS process. The experimental results show, within the effective input dynamic range of 0~20 mV which is equivalent to an X-ray energy band from 0 to 18.25 keV, its integral nonlinearity (INL) is 0.032 % and equivalent noise charge (ENC) is 8.6 e- under 100 kHz pixel rate, whilst the total power consumption is only 8.5 mW from a single 3.3 V supply voltage. When tested with the target X-ray CCD–CCD236 using a 1 μCi 55Fe radioisotope, the ASIC achieves together with the CCD an overall energy resolution characterized by full-width-half-magnitude (FWHM) as 165 ± 4.5 eV@5.9 keV and a total ENC as 10.3 e- where CCD236 is cooled down to in the vicinity of 190 K.
8 May 2020 in IEEE Transactions on Nuclear Science
Correlated double sampling (CDS) circuits are essential to processing the X-ray charge-coupled devices (CCDs) that have been widely used in the modern X-ray astronomical field. For timing observations, both energy resolution and timing resolution are of great importance. We are developing the XCR4C application-specific integrated circuit (ASIC), which is a fully customized four-channel radiation-hardened CDS ASIC targeting the readout of X-ray CCDs, for future space astronomical missions. The ASIC is implemented in a differential switched-capacitor architecture, making it highly linear, low power, immune to common-mode noise and interferences, as well as easily configurable. To combat the harsh low-earth-orbit space environment, some radiation-hardening techniques are applied, including the process hardening method, even-finger double-side bulk butting, and pseudo-double guard ring layout techniques. The XCR4C ASIC was fabricated with 0.35-μm 2P4M CMOS technology with an epitaxial layer. The ASIC achieves a maximum 23-ppm integral nonlinearity and 5.8 e- rms equivalent noise charge under a typical 1-MHz pixel rate and only consumes 50 mW approximately from a single 3.3-V supply voltage. The results from radiation hardness assurance testing show that the ASIC has at least a total ionizing dose tolerance of 300 krad(Si), and no single-event latchup has been found up to a linear energy transfer of 81.35 MeV · cm 2 /mg with a total fluence up to 1.68 × 10 7 ions/cm 2 .
18 May 2023 in IEEE Transactions on Nuclear Science
For more than two decades, amplifier-discriminator ASICs have been demonstrated to be the optimal choice for time measurement in high-energy physics experiments. With the requirement of time resolution further evolving towards the picosecond and sub-picosecond ranges, circuit innovation has become increasingly essential. We present a PIcoSecond Timing (PIST1) ASIC, utilizing the conventional amplifier-discriminator architecture and optimized for the readout of silicon photomultipliers (SiPMs) in the electromagnetic calorimeter (ECAL) for future Higgs factories such as the Circular Electron Positron Collider (CEPC). Further circuit developments are made to enable the ASIC to operate under minimal power with reduced supply voltage. A comprehensive analysis of the noise in the signal link is also conducted and the findings presented. A single-channel prototype is designed in 55 nm CMOS with a single 1.2 V supply voltage. The standalone ASIC testing highlights a time resolution of 4.20±0.04 ps for a minimum ionizing particle (MIP) which is equivalent to 32 pC charge. Additionally, a linear time-over-threshold (ToT) response from 1 to 12 MIP is attained and typical 15 mW power consumption realized.
6 September 2017 in Nuclear Science and Techniques