Ana Paula Terossi de Godoi

Ana Paula Terossi de Godoi

Auto-generated profile, based on publicly available information

Ana Paula Terossi de Godoi

Department of Orthodontics, Hermínio Ometto Foundation—FHO , Araras, SP, 13607-339 , Brazil

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2012 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
KTKeico Graciela Sano Trauth
Keico Graciela Sano Trauth
AGAna Paula Terossi de Godoi
Ana Paula Terossi de Godoi
VCVivian Colucci
Vivian Colucci
SCSilmara Aparecida Milori Corona
Silmara Aparecida Milori Corona
ACAlma Blásida Concepción Elizaur Benitez Catirse
Alma Blásida Concepción Elizaur Benitez Catirse
The aim of this study was to determine the influence of mouthrinses on the surface roughness of a nanofilled composite resin after toothbrushing. One hundred nanofilled composite resin specimens were prepared and randomly distributed into two groups-brushed and non-brushed-and then assigned to five subgroups, according to the mouthrinse solutions (n = 10): Colgate Plax Fresh Mint, Oral B, Cepacol, Colgate Plax, and artificial saliva. Each sample was immersed in 20 mL of the mouthrinses for 1 minute, 5 days per week, twice a day, for a 3-week period. The control group used in the study was one in which the specimens were not subjected to brushing and remained only in artificial saliva. Toothbrushing was performed once a week for 1 minute, for 3 weeks. Surface roughness measurements (Ra) were performed after the immersion period and toothbrushing, by means of a profilometer. Data were analyzed by two-way ANOVA and Tukey's test. Analysis revealed that the association between toothbrushing and Colgate Plax Fresh Mint produced the lowest surface roughness (p < 0.05). All other groups tested (Oral B, Cepacol, Colgate Plax, artificial saliva) exhibited no statistically significant differences between surfaces, whether subjected to toothbrushing or not (p < 0.05). It was concluded that the surface roughness of the nanofilled composite resin tested can be influenced by the mouthrinse associated with toothbrushing.

1 June 2015 in Brazilian Dental Journal
Verified
Journal Article
Open access
PDF file
ARAna Carolina Cabral Roque
Ana Carolina Cabral Roque
LBLauren Oliveira Lima Bohner
Lauren Oliveira Lima Bohner
AGAna Paula Terossi de Godoi
Ana Paula Terossi de Godoi
VCVivian Colucci
Vivian Colucci
SCSilmara Aparecida Milori Corona
Silmara Aparecida Milori Corona
ACAlma Blásida Concepción Elizaur Benitez Catirse
Alma Blásida Concepción Elizaur Benitez Catirse
The purpose of this study was to determine the influence of hydrochloric acid on surface roughness of composite resins subjected to brushing. Sixty samples measuring 2 mm thick x 6 mm diameter were prepared and used as experimental units. The study presented a 3x2 factorial design, in which the factors were composite resin (n=20), at 3 levels: microhybrid composite (Z100), nanofilled composite (FiltekTM Supreme), nanohybrid composite (Ice), and acid challenge (n=10) at 2 levels: absence and presence. Acid challenge was performed by immersion of specimens in hydrochloric acid (pH 1.2) for 1 min, 4 times per day for 7 days. The specimens not subjected to acid challenge were stored in 15 mL of artificial saliva at 37 oC. Afterwards, all specimens were submitted to abrasive challenge by a brushing cycle performed with a 200 g weight at a speed of 356 rpm, totaling 17.8 cycles. Surface roughness measurements (Ra) were performed and analyzed by ANOVA and Tukey test (p≤0.05). Surface roughness values were higher in the presence (1.07±0.24) as compared with the absence of hydrochloric acid (0.72±0.04). Surface roughness values were higher for microhybrid (1.01±0.27) compared with nanofilled (0.68 ±0.09) and nanohybrid (0.48±0.15) composites when the specimens were not subjects to acid challenge. In the presence of hydrochloric acid, microhybrid (1.26±0.28) and nanofilled (1.18±0,30) composites presents higher surface roughness values compared with nanohybrid (0.77±0.15). The hydrochloric acid affected the surface roughness of composite resin subjected to brushing.

26 August 2021 in Cranio®
Verified
Journal Article
Closed access
MRMariane Porto Righi
Mariane Porto Righi
AGAna Paula Terossi De Godoi
Ana Paula Terossi De Godoi
GVGiovana Cherubini Venezian
Giovana Cherubini Venezian
VDViviane Veroni Degan
Viviane Veroni Degan
CMCarolina Carmo de Menezes
Carolina Carmo de Menezes
The aim of this study was to assess the association between the symptoms of temporomandibular disorder (TMD), sleep quality, and indicators of burnout syndrome in teachers.This cross-sectional stud...

1 September 2016 in European Journal of General Dentistry
Verified
Journal Article
Open access
PDF file
LBLauren Oliveira Lima Bohner
Lauren Oliveira Lima Bohner
AGAna Paula Terossi de Godoi
Ana Paula Terossi de Godoi
AAAhad Shahid Ahmed
Ahad Shahid Ahmed
PNPedro Tortamano Neto
Pedro Tortamano Neto
ACAlma Blasida Concepcion Elizaur Benitez Catirse
Alma Blasida Concepcion Elizaur Benitez Catirse
Objective: To evaluate the surface roughness of resin composite and ceramic material after immersion in mouthwashes. Methodology: Thirty specimens of resin composite and ceramic material were prepared with a stainless steel matrix (6 mm × 2 mm). The samples of each material were divided into three groups (n = 10), according to the mouthwashes: Distilled water (DW), chlorhexidine (CL) 0.12%, and cetylpyridinium chloride (CC). Specimens were individually submitted to the immersion cycle in 15 mL of mouthwash for 30 days, three times per day, for 1 min/cycle. Surface roughness measurements were performed at three different time intervals: Before the first cycle (T0), after 7 (T1), and 30 days (T2) of immersion. Data were analyzed by the two-way ANOVA and Tukey tests (P ≤ 0.05). Results: There was no statistically significant difference in surface roughness of resin composite among mouthwashes (DW - 1.4 ± 0.13 μm; CL - 1.16 ± 0.13 μm; CC - 1.18 ± 0.13 μm). Surface roughness was statistically significantly lower after 30 days (T2-0.56 ± 0.60 μm) compared with the initial period (T0-1.63 ± 0.60 μm) and after 7 days (T1-1.57 ± 0.60 μm). For ceramic material, CC (3.75 ± 0.60 μm) caused a higher level of surface roughness compared with DW (2.57 ± 0.60 μm) and CL (3.39 ± 0.60 μm). There was no statistically significant difference among the different time intervals (T0-3.05 ± 0.18 μm; T1-3.41 ± 0.18 μm; T2-3.26 ± 0.18 μm). Conclusion: Mouthwashes did not promote a significant change in surface roughness of composite resin. Cetylpyridinium chloride promoted an increase in surface roughness of dental ceramic.

1 January 2021 in Dental Press Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
AMAmanda Galindo Florêncio Miranda
Amanda Galindo Florêncio Miranda
AGAna Paula Terossi de Godoi
Ana Paula Terossi de Godoi
CMCarolina Carmo de Menezes
Carolina Carmo de Menezes
MFMário Vedovello Filho
Mário Vedovello Filho
GVGiovana Cherubini Venezian
Giovana Cherubini Venezian
Aim: To assess the influence of elastomeric ligatures, subjected to a previous in vitro pigmentation process using different substances, on smile aesthetics during orthodontic treatment, from the perception of students and professionals. Methods: Eight elastomeric ligatures of five commercial brands (3M/Unitek, American Orthodontics, Morelli, Ortho Technology, and Orthometric) (n=8) were immersed in coffee, Coca-Cola, and red wine for one minute per day, for 28 days; and another group of ligatures was immersed in artificial saliva. All samples were photographed and subsequently analyzed using the Adobe Photoshop software, by the RGB method. Afterwards, the pigmented ligatures were inserted in a patient wearing orthodontic brackets, and zoomed photographs of the smile were taken and presented to 40 evaluators, who filled in a satisfaction scale sheet to express their opinion on the smile aesthetics of each photograph. The color data were subjected to analysis of variance (ANOVA) and Tukey tests. Results: The substance with the highest pigmentation potential was coffee (p< 0.05) followed by red wine (p< 0.05). Comparison among the brands used in this study showed that American Orthodontics and Orthometric had the lowest degree of pigmentation when immersed in coffee and red wine (p< 0.05), respectively. However, the brand that showed the highest level of satisfaction among the evaluators was Ortho Technology. Conclusions: The presence of pigmented elastomeric ligatures affected smile aesthetics, when compared with the control group.

1 January 2019 in Revista de Odontologia da UNESP
Verified
Journal Article
Open access
PDF file
TKTársio Caleb Bernardon Kieling
Társio Caleb Bernardon Kieling
LCLourenço Correr-Sobrinho
Lourenço Correr-Sobrinho
AGAna Paula Terossi de Godoi
Ana Paula Terossi de Godoi
CMCarolina Carmo de Menezes
Carolina Carmo de Menezes
GVGiovana Cherubini Venezian
Giovana Cherubini Venezian
ACAna Rosa Costa
Ana Rosa Costa
Introduction In recent years, there has been an increasing demand for esthetic treatments, especially among orthodontic patients. Objective This study determined the fracture strength of monocrystalline and polycrystalline ceramic brackets of different manufacturers during archwire torque. Material and method Sixty ceramic brackets (Roth, right upper central incisors, 0.022 x 0.028-inch slot) were allocated into two groups (30 specimens per group) according to the type of ceramics: monocrystalline and polycrystalline. Subsequently, the groups were divided into three subgroups (n = 10) according to the manufacturer: Orthometric, Eurodonto and Ortho Technology. Sixty PVC cylinders were filled with chemically activated acrylic resin (CAAR), the brackets were fixed with CAAR onto the cylinder surface and the excess material was used to partially cover the base of the bracket. After 24h, the U-shaped wire base (0.019 x 0.025 inches; 6 mm height and width) was inserted into the bracket slot and fixed thereon with a stainless-steel wire. Vertical folds were made at the ends of the “U” to support the universal test machine chisel. The fracture strength test was performed at a speed of 1.0 mm/min until fracture into a universal test machine (Instron). The data were recorded, transformed into g.mm and submitted to two-way ANOVA followed by Tukey’s post-hoc test (SAS Institute Inc., Cary, NC, USA, version 9.3) (α=5%). Result Monocrystalline brackets showed a higher fracture strength than polycrystalline brackets, regardless of the manufacturer (p0.05). Conclusion Monocrystalline ceramic brackets have a higher fracture strength than polycrystalline brackets, with significant manufacturer-dependent differences.