A newly combined, comprehensive, rapid and high-throughput doping control screening method for the analysis of 350 substances with different polarities in human urine using UPLC-QE Plus-HRMS and UPLC-QQQ-MS has been developed and validated.
This study described a reliable analytical method, which combines solid-phase extraction (SPE) with liquid chromatography-high resolution mass spectrometry (LC-HRMS) employing the parallel reaction monitoring (PRM) mode, for screening 41 small peptides and 3 non-peptide growth hormone secretagogues in human urine. Additionally 36 small peptides and 3 non-peptide growth hormone secretagogues were also confirmed in the same way. For the whole screening procedure, the PRM mode was applied to the HRMS detection of small peptides, which reduces the background noise from matrix compounds to a large extent and thus improves the selectivity and reliability of the peptide analytes. Meanwhile, competent chromatographic separation was achieved within a total runtime of 14 minutes, indicating an improvement in the detection efficiency. Moreover, the PRM mode could also be applied to the confirmation procedure due to its strong identification power with a low risk of generating false positives or negatives and good selectivity. Validation was performed according to the relevant World Anti-Doping Agency (WADA) criteria, including selectivity and reliability, limit of detection (LOD), limit of identification (LOI), recovery, extraction stability and carryover. The LODs of the peptide analytes ranged between 0.20 ng mL−1 and 0.92 ng mL−1 in urine, while their LOIs ranged between 0.20 ng mL−1 and 2.00 ng mL−1, which met the corresponding Minimum Required Performance Levels (MRPLs) as defined by WADA. The developed method furnished the rapid and sensitive detection of small peptides in urine for more than 5000 samples with no false-positive or false-negative, indicating that it is an eligible method for doping control analysis.
2 April 2022 in Journal of Chromatographic Science
An accurate quantitative method for four prohibited ephedrine substances in human urine has been established, based on ultra-performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS). The quantitative bias caused by pretreatment operations and matrix effects was reduced by the dilute and shoot pretreatment method. The good separation of isomers was achieved with the advantages of the UPLC instrument and Agilent Poroshell 120 EC-C8 UPLC column. Stable quantitative ions were selected during the analysis with MS/MS. The result of the method validation experiment showed an excellent linearity between 50% and 200% threshold concentration with a correlation coefficient (r2) greater than 0.999. The coefficient of variation at the limit of quantification and threshold was <20% and 10%, respectively. The uncertainty was below the maximum uncertainty specified in the technical document of the World Anti-Doping Agency (WADA). The analytical result using this method has passed the WADA-external quality assessment scheme. The anti-doping laboratory has applied the method in routine tests and reported adverse analytical finding.