Kunpeng Zhoua

Kunpeng Zhoua

Auto-generated profile, based on publicly available information

Kunpeng Zhoua

Electric Power Research Institute, State Grid Hubei Electric Power Co., Ltd., Wuhan, 430077, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2020 in IEEE Access
Verified
Journal Article
Open access
ZTZeyang Tang
Zeyang Tang
YSYu Shen
Yu Shen
KZKunpeng Zhoua
Kunpeng Zhoua
KCKan Cao
Kan Cao
FYFan Yang
Fan Yang
CZChengke Zhoua
Chengke Zhoua
Many power utilities may have problems with the quality of data in records about which feeder a distribution transformer is connected to. This affects the operation and maintenance of smart grid infrastructure, outage management, line loss management, and workforce safety. The traditional manual way of verifying and updating the distribution transformer connectivity (DTC) is time-consuming and labor-intensive. Researchers have proposed the method which makes use of secondary side single-phase voltage of distribution transformers to verify DTC. However, when the windings of distribution transformers are yyn0 connected, the performance of the single-phase voltage method (SPVM) is unsatisfactory due to the unbalanced three-phase voltages. This paper proposed a dimension reduction method (DRM) that can convert the unbalanced three-phase voltage to a balanced voltage. The data which include 29 days’ secondary side voltages of 3866 distribution transformers have been collected. The performances of the DRM and the SPVM have been compared. Results show that the DRM always has higher accuracy compared with SPVM. The influences of the maximum voltage difference and the reference distribution transformer have also been discussed. The DRM’s results are more stable compared with SPVM.

1 September 2018
Verified
Conference Paper
Closed access
XYXiaodong Yu
Xiaodong Yu
KCKan Cao
Kan Cao
YDYameng Dai
Yameng Dai
ZTZeyang Tang
Zeyang Tang
KZKunpeng Zhou
Kunpeng Zhou
As MMC-HVDC system is of a large number of applications, the mechanism of its influence on the SSO characteristics of the adjacent units needs to be studied. This article proposed the coupling loop of the voltage disturbance between HVDC system and the AC bus, and further established the response characteristics equations of MMC-HVDC control system between amplitude and phase perturbation of the AC bus voltage. Then, the damping characteristics based on response characteristic equations above were analyzed to reveal the phenomena and reason of the weak connection between MMC-HVDC and the units' SSO characteristics. Finally, the results are verified by electromagnetic transient simulations. The results show that MMC-HVDC system has weaker damping effect on the units' SSO characteristics.