Zeyang Tang

Dr. Zeyang Tang


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2025 in Energies
Verified
Journal Article
Open access
PDF file
YCYang Chen
Yang Chen
ZTZeyang Tang
Zeyang Tang
YCYibo Cui
Yibo Cui
WRWei Rao
Wei Rao
YLYiwen Li
Yiwen Li
The accurate estimation and prediction of charging demand are crucial for the planning of charging infrastructure, grid layout, and the efficient operation of charging networks. To address the shortcomings of existing methods in utilizing the spatial interdependencies among urban regions, this paper proposes a forecasting approach that integrates dynamic time warping (DTW) with a spatial–temporal attention graph convolutional neural network (ASTGCN). First, this method delves into the correlations between various regions within the target city, establishing intricate coupling relationships among them. Subsequently, the FastDTW algorithm is employed to construct an adjacency matrix, capturing the spatiotemporal correlation among different urban regions. Finally, the ASTGCN model is applied to predict the power load of each region, which can accurately capture the spatiotemporal characteristics of the power load. The experimental results indicate that the proposed model has a more powerful comprehensive ability to capture spatiotemporal relationships and improve accuracy and stability in different prediction steps.

31 July 2024 in Electric Power Systems Research
Verified
Journal Article
Closed access
MTMingwei Tang
Mingwei Tang
YGYujun Guo
Yujun Guo
SXSong Xiao
Song Xiao
JZJiani Zeng
Jiani Zeng
HZHemin Zhong
Hemin Zhong
GWGuangning Wu
Guangning Wu

27 April 2020 in IEEE Access
Verified
Journal Article
Open access
ZTZeyang Tang
Zeyang Tang
YSYu Shen
Yu Shen
KZKunpeng Zhoua
Kunpeng Zhoua
KCKan Cao
Kan Cao
FYFan Yang
Fan Yang
CZChengke Zhoua
Chengke Zhoua
Many power utilities may have problems with the quality of data in records about which feeder a distribution transformer is connected to. This affects the operation and maintenance of smart grid infrastructure, outage management, line loss management, and workforce safety. The traditional manual way of verifying and updating the distribution transformer connectivity (DTC) is time-consuming and labor-intensive. Researchers have proposed the method which makes use of secondary side single-phase voltage of distribution transformers to verify DTC. However, when the windings of distribution transformers are yyn0 connected, the performance of the single-phase voltage method (SPVM) is unsatisfactory due to the unbalanced three-phase voltages. This paper proposed a dimension reduction method (DRM) that can convert the unbalanced three-phase voltage to a balanced voltage. The data which include 29 days’ secondary side voltages of 3866 distribution transformers have been collected. The performances of the DRM and the SPVM have been compared. Results show that the DRM always has higher accuracy compared with SPVM. The influences of the maximum voltage difference and the reference distribution transformer have also been discussed. The DRM’s results are more stable compared with SPVM.

2 March 2023 in IEEE Access
Verified
Journal Article
Open access
ZTZeyang Tang
Zeyang Tang
GLGang Li
Gang Li
SXSONG XIAO
SONG XIAO
XDXiaoxun Deng
Xiaoxun Deng
LRLing Ruan
Ling Ruan
MLMingzhen Li
Mingzhen Li
During the operation of the urban subway, there will be stray current leaking into the ground, which may invade the neutral point of the transformer along the subway line, causing the working magnetization curve of the transformer core to shift, thereby causing the direct-current (DC) bias effect of the transformer. Since there are unknown parameters in the equivalent circuit model of the stray current of the subway, in order to simplify the process of the influence of the subway operation on the neutral current, based on the analysis of the formation mechanism of stray current, a real subway line has been selected and a monitoring platform in the nearby high-voltage (HV) substation has been built to record the neutral current. Meanwhile, through the on-site recording of the entry and exit time of subway trains at four consecutive stations, the running trajectories of the subway trains can be reversed. According to the trajectory of the subway train, the recorded neutral current was re-divided into time periods, and the synergistic analysis of the neutral current and the train trajectory in the corresponding time period was carried out. The neutral current measurement results for 4 consecutive days indicate that the influence of the subway train on the neutral current of the substation is mainly the influence of the unbalanced load, and the degree of the unbalance mainly comes from the distance and the acceleration and braking of the subway train. The trajectory of the subway train is related to the amplitude of the neutral current. The closer the subway train is to the substation, the greater the impact on the neutral current.

Verified
Journal Article
Open access
PDF file
ZTZeyang Tang
Zeyang Tang
HBHu Qi Biao
Hu Qi Biao
YCYi-Bo Cui
Yi-Bo Cui
LHLei Hu
Lei Hu
YLYi-Wen Li
Yi-Wen Li
YLYu-Jie Li
Yu-Jie Li
This paper aims to address the issue of evaluating the operation of electric vehicle charging stations (EVCSs). Previous studies have commonly employed the method of constructing comprehensive evaluation systems, which greatly relies on manual experience for index selection and weight allocation. To overcome this limitation, this paper proposes an evaluation method based on natural language models for assessing the operation of charging stations. By utilizing the proposed SimCSEBERT model, this study analyzes the operational data, user charging data, and basic information of charging stations to predict the operational status and identify influential factors. Additionally, this study compared the evaluation accuracy and impact factor analysis accuracy of the baseline and the proposed model. The experimental results demonstrate that our model achieves a higher evaluation accuracy (operation evaluation accuracy = 0.9464; impact factor analysis accuracy = 0.9492) and effectively assesses the operation of EVCSs. Compared with traditional evaluation methods, this approach exhibits improved universality and a higher level of intelligence. It provides insights into the operation of EVCSs and user demands, allowing for the resolution of supply–demand contradictions that are caused by power supply constraints and the uneven distribution of charging demands. Furthermore, it offers guidance for more efficient and targeted strategies for the operation of charging stations.

1 September 2018
Verified
Conference Paper
Closed access
XYXiaodong Yu
Xiaodong Yu
KCKan Cao
Kan Cao
YDYameng Dai
Yameng Dai
ZTZeyang Tang
Zeyang Tang
KZKunpeng Zhou
Kunpeng Zhou
As MMC-HVDC system is of a large number of applications, the mechanism of its influence on the SSO characteristics of the adjacent units needs to be studied. This article proposed the coupling loop of the voltage disturbance between HVDC system and the AC bus, and further established the response characteristics equations of MMC-HVDC control system between amplitude and phase perturbation of the AC bus voltage. Then, the damping characteristics based on response characteristic equations above were analyzed to reveal the phenomena and reason of the weak connection between MMC-HVDC and the units' SSO characteristics. Finally, the results are verified by electromagnetic transient simulations. The results show that MMC-HVDC system has weaker damping effect on the units' SSO characteristics.