Ferenc Varga

Ferenc Varga

Auto-generated profile, based on publicly available information

Ferenc Varga

Nemzeti Közszolgálati Egyetem

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2023 in IDRiM Journal
Verified
Journal Article
Open access
PDF file
GÉGergő Érces
Gergő Érces
SRSándor Rácz
Sándor Rácz
GVGyula Vass
Gyula Vass
FVFerenc Varga
Ferenc Varga
Today, smart city principles are emerging as a highly relevant method in contemporary urban planning and development. In line with international trends, nations almost without exception have smart city strategies. The assessment system supporting smart development strategies for EU municipalities defines complex indicators in six thematic sub-systems: smart mobility, smart environment, smart people, smart living conditions, smart governance, smart economy. One monitoring aspect of the smart living subsystem is safety. The smart cities of the future will be made up of a network of smart buildings, which will fundamentally determine fire safety based on prevention. In this monitoring theme, the researchers will show how the future of fire safety - a cornerstone of safety- will evolve in smart buildings of smart cities. The researchers will describe the potential of building a smart fire safety network using data generated by building information modelling. They will show how BIM-based complex digital fire safety can be integrated into the fire safety network based on the new digital “one urban one plan” regulation in Hungary. The authors show that their method is suitable for the expansion of a smart cities database based on a digital urban plan.

1 September 2023 in Fire
Verified
Journal Article
Open access
PDF file
MKMaxim Kátai-Urbán
Maxim Kátai-Urbán
TBTibor Bíró
Tibor Bíró
LKLajos - Kátai-Urbán
Lajos - Kátai-Urbán
FVFerenc Varga
Ferenc Varga
ZCZsolt Cimer
Zsolt Cimer
Major accidents involving flammable substances can lead to significant environmental damage. The operators of chemical warehouses—in order to prevent and mitigate harmful environmental impacts—based on fire prevention strategies should apply “firewater pollution prevention” (FPP) measures. The identification of affected warehouses already in operation is an important law enforcement task. Therefore, the authors—based on the assessment of firewater run-off scenarios—propose a simple and easy-to-use dangerous establishment identification procedure and methodology based on event tree analysis and indexing preliminary risk analysis approaches. Two independent expert groups validated—in the case of 10 facilities—the index components of the approach. The testing of the applicability of the approach took place in parallel with the analyses of the Hungarian operator’s practice. The research results—covering the inspection of 24 facilities—can assist the operators in the effective and unified implementation of FPP measures. In the case of 14 facilities, it was necessary to introduce FPP measures, which highlight the need to improve the law enforcement compliance of identified operators. The investigation results can also contribute to increases in the fire and environmental safety performance of chemical warehouses, which ensures a higher level of environmental protection and people’s health near chemical warehouses.

25 May 2024 in Belügyi Szemle
Verified
Journal Article
Open access
PDF file
GVGyula Vass
Gyula Vass
JAJózsef Ambrusz
József Ambrusz
Agoston RestasAgoston Restas
Agoston Restas
FVFerenc Varga
Ferenc Varga
LKLajos - Kátai-Urbán
Lajos - Kátai-Urbán
Aim: The purpose of this study is to analyse and evaluate the main results and experiences of disaster management research and development activities, on the basis of which to determine future development directions. Methodology: The impact assessment prepared in the framework of the study presents the characteristics of disaster management research and development activities, and also makes structured proposals for solving the appeared research problems. Findings: The results of disaster management scientific activity carried out as part of law enforcement researches provide an opportunity to modernise the legal regulatory, professional and technical bases of disaster management administration in a manner appropriate to recent scientific development. Value: The disaster management research and development experiences processed in the framework of the study provide a suitable basis for a high level of compliance with the relevant social needs.

25 December 2024 in Fire
Verified
Journal Article
Open access
PDF file
IMIstván Mihály
István Mihály
LBLászló Bérczi
László Bérczi
BBBalázs Bognár
Balázs Bognár
MKMaxim Kátai-Urbán
Maxim Kátai-Urbán
LTLevente Toth
Levente Toth
FVFerenc Varga
Ferenc Varga
On the occasion of building fires, the risk of smoke, which adversely influences escape conditions, must be minimised. One way to reduce the risk is, for example, to pressurise the escape route in order to limit the infiltration of smoke. Careful determination of the design parameters of the pressurisation system is of great importance. This study will propose a new leakage area for single-leaf smoke control doors based on the analysis of the leakage area of the doors in the EN 12101-13 standard, estimating the leakage rate through closed doors. This value is half the currently recommended value, regardless of the opening direction. The determination of the leakage area is supported by measurements in pressurised smoke-free lobbies with single-leaf smoke control doors opening into and outwards from a pressurised space. The measurements are performed using the fans of the lobbies’ pressurisation systems to provide the required air volume. The suitability of this method has also been tested using blower door assembly measurements. The newly proposed leakage area takes into account the increased air tightness of the smoke control doors, thereby ensuring that the optimum air volume to be supplied by the pressurisation system can be determined. The results of this research suggest an appropriate leakage area value for designers when using the calculation method proposed by the applicability of the investigated standard.

25 May 2024 in Belügyi Szemle
Verified
Journal Article
Open access
PDF file
GVGyula Vass
Gyula Vass
JAJózsef Ambrusz
József Ambrusz
Agoston RestasAgoston Restas
Agoston Restas
FVFerenc Varga
Ferenc Varga
LKLajos - Kátai-Urbán
Lajos - Kátai-Urbán
Aim: The purpose of this study is to analyse and evaluate the main results and experiences of disaster management research and development activities, on the basis of which to determine future development directions. Methodology: The impact assessment prepared in the framework of the study presents the characteristics of disaster management research and development activities, and also makes structured proposals for solving the appeared research problems. Findings: The results of disaster management scientific activity carried out as part of law enforcement researches provide an opportunity to modernise the legal regulatory, professional and technical bases of disaster management administration in a manner appropriate to recent scientific development. Value: The disaster management research and development experiences processed in the framework of the study provide a suitable basis for a high level of compliance with the relevant social needs.

1 January 2023 in Hadmérnök
Verified
Journal Article
Open access
PDF file
IMIstván Mihály
István Mihály
FVFerenc Varga
Ferenc Varga
Pressurised staircases play an important role in ensuring both safe evacuation and conditions for rescue and firefighting intervention. Occupants may be delayed in getting to safety or extinguishing the fire for unforeseen reasons. In some cases, the pressurised staircase or its lobby may serve as a temporary protected area for persons unable to escape independently, which should ensure the safety of the persons fleeing or being evacuated for a limited period of time. In such cases, the role of effective smoke control should be a priority. The purpose of pressurisation is to prevent the entry of smoke and toxic combustion gases at dangerous levels, but the possibility cannot be excluded. In the present series of studies, the smoke flow in a pressurised staircase was investigated in order to gain experience of the characteristics of smoke movement and propagation under these conditions.This involved a series of experiments with smoke cartridges placed on different staircase levels, supported by ventilation measurements to investigate the smoke flow. Based on the results of the measurements and observations, we proposed possible improvements to the technical solutions.