Eli Mizrachi

Eli Mizrachi

Auto-generated profile, based on publicly available information

Eli Mizrachi

Physics Department, University of Maryland, College Park, Maryland 20742, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2024 in Physical Review D
Verified
Journal Article
Open access
PDF file
JXJ. Xu
J. Xu
DAD. Adams
D. Adams
BLB. G. Lenardo
B. G. Lenardo
TPT. Pershing
T. Pershing
RMR. L. Mannino
R. L. Mannino
MTM. Tripathi
M. Tripathi
The Migdal effect predicts that a nuclear recoil interaction can be accompanied by atomic ionization, allowing many dark matter direct detection experiments to gain sensitivity to sub-GeV masses. We report the first direct search for the Migdal effect for M- and L-shell electrons in liquid xenon using nuclear recoils produced by tagged neutron scatters. Despite an observed background rate lower than that of expected signals in the region of interest, we do not observe a signal consistent with predictions. We discuss possible explanations, including inaccurate predictions for either the Migdal rate or the signal response in liquid xenon. We comment on the implications for direct dark matter searches and future Migdal characterization efforts. Published by the American Physical Society 2024

20 October 2023 in Physical Review C
Verified
Journal Article
Closed access
PDF file
EBE. P. Bernard
E. P. Bernard
EME. Mizrachi
E. Mizrachi
JKJ. Kingston
J. Kingston
JXJ. Xu
J. Xu
SPS. V. Pereverzev
S. V. Pereverzev
PBP. S. Barbeau
P. S. Barbeau
Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we analyze the causes of these instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with O(1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. This work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

30 September 2022 in Physical Review D
Verified
Journal Article
Closed access
PDF file
TPT. Pershing
T. Pershing
DND. Naim
D. Naim
BLB. G. Lenardo
B. G. Lenardo
JXJ. Xu
J. Xu
JKJ. Kingston
J. Kingston
MTM. Tripathi
M. Tripathi
Liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models, but few xenon recoil calibrations above 100 keV are currently available. In this work, we measured the scintillation and ionization yields of xenon recoils up to 426 keV. The experiment uses 14.1 MeV neutrons to scatter off xenon in a compact liquid xenon time projection chamber and produce quasimonoenergetic xenon recoils between 39 and 426 keV. We report the xenon recoil responses and their electric field dependence for recoil energies up to 306 keV; due to the low event statistics and the relatively mild field dependence, the yield values at higher energies are reported as the average of xenon responses for electric fields between 0.2 and 2.0  kV/cm. This result will enable xenon-based dark matter experiments to significantly increase their high-energy dark matter sensitivities by including energy regions that were previously inaccessible due to lack of calibrations.

29 October 2022 in arXiv
Verified
Preprint
Open access
PDF file
TPTeal Pershing
Teal Pershing
DNDaniel Naim
Daniel Naim
BLBrian Lenardo
Brian Lenardo
JXJingke Xu
Jingke Xu
JKJames Kingston
James Kingston
MTMani Tripathi
Mani Tripathi
Liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models, but few xenon recoil calibrations above 100 keV are currently available. In this work, we measured the scintillation and ionization yields of xenon recoils up to 426 keV. The experiment uses 14.1 MeV neutrons to scatter off xenon in a compact liquid xenon time projection chamber and produce quasi-monoenergetic xenon recoils between 39 keV and 426 keV. We report the xenon recoil responses and their electric field-dependence for recoil energies up to 306 keV; due to the low event statistics and the relatively mild field dependence, the yield values at higher energies are reported as the average of xenon responses for electric fields between 0.2-2.0 kV/cm. This result will enable xenon-based dark matter experiments to significantly increase their high energy dark matter sensitivities by including energy regions that were previously inaccessible due to lack of calibrations.

12 September 2022 in arXiv
Verified
Preprint
Open access
PDF file
EBEthan P. Bernard
Ethan P. Bernard
EMEli Mizrachi
Eli Mizrachi
JKJames Kingston
James Kingston
JXJingke Xu
Jingke Xu
SPSergey V. Pereverzev
Sergey V. Pereverzev
PBPhillip S. Barbeau
Phillip S. Barbeau
Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we discuss the causes for such instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with O(1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. This work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.