Ethan P. Bernard

Ethan P. Bernard

Auto-generated profile, based on publicly available information

Ethan P. Bernard

Lawrence Livermore National Laboratory

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2023 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
MAM. Andriamirado
M. Andriamirado
ABA. B. Balantekin
A. B. Balantekin
CBC. D. Bass
C. D. Bass
DBD. E. Bergeron
D. E. Bergeron
EBE. P. Bernard
E. P. Bernard
PCPROSPECT Collaboration
PROSPECT Collaboration
This Letter reports one of the most precise measurements to date of the antineutrino spectrum from a purely U235-fueled reactor, made with the final dataset from the PROSPECT-I detector at the High Flux Isotope Reactor. By extracting information from previously unused detector segments, this analysis effectively doubles the statistics of the previous PROSPECT measurement. The reconstructed energy spectrum is unfolded into antineutrino energy and compared with both the Huber-Mueller model and a spectrum from a commercial reactor burning multiple fuel isotopes. A local excess over the model is observed in the 5–7 MeV energy region. Comparison of the PROSPECT results with those from commercial reactors provides new constraints on the origin of this excess, disfavoring at 2.0 and 3.7 standard deviations the hypotheses that antineutrinos from U235 are solely responsible and noncontributors to the excess observed at commercial reactors, respectively.

1 November 2017 in Journal of Instrumentation
Verified
Journal Article
Open access
PDF file
DAD.S. Akerib
D.S. Akerib
SAS. Alsum
S. Alsum
HAH.M. Araújo
H.M. Araújo
XBX. Bai
X. Bai
ABA.J. Bailey
A.J. Bailey
CZC. Zhang
C. Zhang

14 April 2025 in Physical Review Letters
Verified
Journal Article
Open access
MAM. Andriamirado
M. Andriamirado
ABA. B. Balantekin
A. B. Balantekin
CBC. D. Bass
C. D. Bass
ORO. Benevides Rodrigues
O. Benevides Rodrigues
EBE. P. Bernard
E. P. Bernard
PCPROSPECT Collaboration
PROSPECT Collaboration
The PROSPECT experiment is designed to perform precise searches for antineutrino disappearance at short distances (7–9 m) from compact nuclear reactor cores. This Letter reports results from a new neutrino oscillation analysis performed using the complete data sample from the PROSPECT-I detector operated at the High Flux Isotope Reactor in 2018. The analysis uses a multiperiod selection of inverse beta decay neutrino interactions with reduced backgrounds and enhanced statistical power to set limits on electron neutrino disappearance caused by mixing with sterile neutrinos with 0.2 – 20 eV 2 mass splittings. Inverse beta decay positron energy spectra from six different reactor-detector distance ranges are found to be statistically consistent with one another, as would be expected in the absence of sterile neutrino oscillations. The data excludes at 95% confidence level the existence of sterile neutrinos in regions above 3 eV 2 previously unexplored by terrestrial experiments, including all space below 10 eV 2 suggested by the recently strengthened Gallium Anomaly. The best-fit point of the Neutrino-4 reactor experiment’s claimed observation of short-baseline oscillation is ruled out at more than 5 standard deviations.

1 February 2020 in Journal of Instrumentation
Verified
Journal Article
Open access
PDF file
DAD.S. Akerib
D.S. Akerib
SAS. Alsum
S. Alsum
HAH.M. Araújo
H.M. Araújo
XBX. Bai
X. Bai
JBJon Balajthy
Jon Balajthy
CZC. Zhang
C. Zhang
We report here methods and techniques for creating an improved model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the β decays of 3H and 14C in the Large Underground Xenon (LUX) detector were used to tune the model, in addition to external data sets that allow for extrapolation beyond the LUX data-taking conditions. This paper also presents techniques used for modeling complicated temporal and spatial detector pathologies that can adversely affect data using a simplified model framework. The methods outlined in this report show an example of the robust applications possible with NEST v2.0 framework and how it can be modified to produce a final, detector-specific, electronic recoil model. This example provides the final model for LUX and detector parameters that will used in the new analysis package, the LUX Legacy Analysis Monte Carlo Application (LLAMA), for accurate reproduction of the LUX data. As accurate background reproduction is crucial for the success of rare-event searches, such as dark matter direct detection experiments, the techniques outlined here can be used in other single-phase and dual-phase xenon detectors to assist with accurate ER background reproduction.

20 October 2023 in Physical Review C
Verified
Journal Article
Closed access
PDF file
EBE. P. Bernard
E. P. Bernard
EME. Mizrachi
E. Mizrachi
JKJ. Kingston
J. Kingston
JXJ. Xu
J. Xu
SPS. V. Pereverzev
S. V. Pereverzev
PBP. S. Barbeau
P. S. Barbeau
Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we analyze the causes of these instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with O(1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. This work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

1 January 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
JWJ. Watson
J. Watson
IOI. Olcina
I. Olcina
JSJ. Soria
J. Soria
DMD. N. McKinsey
D. N. McKinsey
SKS. Kravitz
S. Kravitz
KOK. O’sUllivan
K. O’sUllivan
Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding 1 m, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment. The Xenon Breakdown Apparatus (XeBrA) is a 5-l, high voltage test chamber built to investigate the contributing factors to electrical breakdown in noble liquids. In this work, we present the main findings after conducting scans over stressed electrode areas, surface finish, pressure, and high voltage ramp speed in the medium of liquid xenon. Area scaling and surface finish were observed to be the dominant factors affecting breakdown, whereas no significant changes were observed with varying pressure or ramp speed. A general rise in both the anode current and photon rate was observed in the last 30 s, leading up to a breakdown, with a marked increase in the last couple of seconds. In addition, the position of breakdowns was reconstructed with a system of high-speed cameras and a moderate correlation with the Fowler–Nordheim field emission model was found. Tentative evidence for bubble nucleation being the originating mechanism of breakdown in the liquid was also observed. We deem the results presented in this work to be of particular interest for the design of future, large TPCs, and practical recommendations are provided.