Purpose. To report long-term visual and refractive results of small-incision lenticule extraction (SMILE) in treatment of high myopia. Materials and Methods. Medical records of patients who underwent SMILE for surgical correction of myopia or myopic astigmatism were retrospectively reviewed. Only patients with a preoperative spherical equivalent of subjective manifest refraction (SE) ≥ 6 D and a postoperative follow-up of 5 years were included in the study. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and SE were analyzed preoperatively and at 1-, 3-, and 5-year postoperative periods. Results. Thirty-seven eyes of 37 patients were included in the study. The mean attempted SE was −7.47 ± 1.10 D (range −6.00 to −10.00 D). At the 5-year visit, the mean difference between achieved and attempted SE was −0.43 ± 0.47 (0.50 to −1.25 D). Mean postoperative UDVA and CDVA were 0.20 ± 0.18 and 0.06 ± 0.08 logMAR, respectively. At the 1-year visit, 70% and 97% of the eyes were within ±0.50 D and ±1.00 D of the intended correction. At the 5-year follow-up, 59% and 92% percent of the eyes were within ±0.50 D and ±1.00 D of the intended SE, respectively. At the 5-year visit, the efficacy index was 0.89 ± 0.26 and the safety index was 1.16 ± 0.20. Fifty-four percent of the eyes gained one or more lines of CDVA. Conclusion. SMILE with an intended correction of up to a spherical equivalent of 10 D is safe and effective. However, there is regression of the refractive effect over extended follow-up.
2 January 2025 in Turkish Journal of Ophthalmology
Readability and Appropriateness of Responses Generated by ChatGPT 3.5, ChatGPT 4.0, Gemini, and Microsoft Copilot for FAQs in Refractive Surgery - Turkish Journal of Ophthalmology
Purpose: To evaluate the long-term refractive outcomes of Eyecryl posterior chamber spherical phakic intraocular lens (pIOL) implantation in high myopia and endothelial cell density (ECD) change. Setting: Beyoglu Eye Training and Research Hospital, Istanbul, Turkey. Design: Retrospective. Methods: Eyes that were not suitable for corneal refractive surgery, had high myopia between −6.00 diopters (D) and −20.00 D, had Eyecryl posterior chamber spherical pIOL implantation, and had at least 5 years of follow-up were included. Preoperative ECD was ≥2300 cells/mm2 and cylindrical value was ≤2.0 D in all cases. Preoperative and postoperative first, third, and fifth years of refraction, uncorrected and corrected distance visual acuity (UDVA/CDVA), and ECD were recorded. Results: 36 eyes of 18 patients were examined. The mean UDVA and CDVA in postoperative fifth years were 0.24 ± 0.19 logMAR and 0.12 ± 0.18 logMAR, respectively. The safety and efficacy indices were 1.52 ± 0.54 and 1.14 ± 0.38, respectively. At 5 years, the spherical equivalent was ±0.50 D in 75% of eyes and ±1.00 D in 92% of eyes. After 5 years, the mean cumulative ECD loss was 6.91% (P = .07). The annual ECD loss was 1.57% in the first year, 0.26% between 1 year and 3 years, and 2.38% between 3 years and 5 years. Asymptomatic anterior capsule opacity developed in 1 eye 4 years after surgery. Rhegmatogenous retinal detachment developed in 1, and myopic choroidal neovascular membrane occurred in 1 eye. Conclusions: Eyecryl posterior chamber spherical pIOL implantation is one of the effective and safe refractive surgical methods in correcting high myopia with predictable and stable refractive results over a 5-year period. Longer-term studies are needed for complications such as decreased ECD, retinal complications, and lens opacity.