sergio uribe

Dr. sergio uribe


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2023 in Medical Image Analysis
Verified
Journal Article
Open access
SDSanuwani Dayarathna
Sanuwani Dayarathna
Kh Tohidul ISLAMKh Tohidul ISLAM
Kh Tohidul ISLAM
SUsergio uribe
sergio uribe
Guang YangGuang Yang
Guang Yang
MHMunawar Hayat
Munawar Hayat
ZCZhaolin Chen
Zhaolin Chen
Medical image synthesis represents a critical area of research in clinical decision-making, aiming to overcome the challenges associated with acquiring multiple image modalities for an accurate clinical workflow. This approach proves beneficial in estimating an image of a desired modality from a given source modality among the most common medical imaging contrasts, such as Computed Tomography (CT), Magnetic Resonance Imaging (MRI), and Positron Emission Tomography (PET). However, translating between two image modalities presents difficulties due to the complex and non-linear domain mappings. Deep learning-based generative modelling has exhibited superior performance in synthetic image contrast applications compared to conventional image synthesis methods. This survey comprehensively reviews deep learning-based medical imaging translation from 2018 to 2023 on pseudo-CT, synthetic MR, and synthetic PET. We provide an overview of synthetic contrasts in medical imaging and the most frequently employed deep learning networks for medical image synthesis. Additionally, we conduct a detailed analysis of each synthesis method, focusing on their diverse model designs based on input domains and network architectures. We also analyse novel network architectures, ranging from conventional CNNs to the recent Transformer and Diffusion models. This analysis includes comparing loss functions, available datasets and anatomical regions, and image quality assessments and performance in other downstream tasks. Finally, we discuss the challenges and identify solutions within the literature, suggesting possible future directions. We hope that the insights offered in this survey paper will serve as a valuable roadmap for researchers in the field of medical image synthesis.

1 January 2018 in NeuroImage: Clinical
Verified
Journal Article
Open access
MZMariana Zurita
Mariana Zurita
CMCristian Montalba
Cristian Montalba
TLTomás Labbé
Tomás Labbé
JCJuan Pablo Cruz
Juan Pablo Cruz
JRJosue Luiz Dalboni da Rocha
Josue Luiz Dalboni da Rocha
SUsergio uribe
sergio uribe
Multiple Sclerosis patients' clinical symptoms do not correlate strongly with structural assessment done with traditional magnetic resonance images. However, its diagnosis and evaluation of the disease's progression are based on a combination of this imaging analysis complemented with clinical examination. Therefore, other biomarkers are necessary to better understand the disease. In this paper, we capitalize on machine learning techniques to classify relapsing-remitting multiple sclerosis patients and healthy volunteers based on machine learning techniques, and to identify relevant brain areas and connectivity measures for characterizing patients. To this end, we acquired magnetic resonance imaging data from relapsing-remitting multiple sclerosis patients and healthy subjects. Fractional anisotropy maps, structural and functional connectivity were extracted from the scans. Each of them were used as separate input features to construct support vector machine classifiers. A fourth input feature was created by combining structural and functional connectivity. Patients were divided in two groups according to their degree of disability and, together with the control group, three group pairs were formed for comparison. Twelve separate classifiers were built from the combination of these four input features and three group pairs. The classifiers were able to distinguish between patients and healthy subjects, reaching accuracy levels as high as 89% ± 2%. In contrast, the performance was noticeably lower when comparing the two groups of patients with different levels of disability, reaching levels below 63% ± 5%. The brain regions that contributed the most to the classification were the right occipital, left frontal orbital, medial frontal cortices and lingual gyrus. The developed classifiers based on MRI data were able to distinguish multiple sclerosis patients and healthy subjects reliably. Moreover, the resulting classification models identified brain regions, and functional and structural connections relevant for better understanding of the disease.

10 December 2019 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Open access
PDF file
NBNicholas Burris
Nicholas Burris
DNDavid A Nordsletten
David A Nordsletten
JSJulio Sotelo
Julio Sotelo
RGRoss Grogan-Kaylor
Ross Grogan-Kaylor
IHIgnas B Houben
Ignas B Houben
HPHimanshu J Patel
Himanshu J Patel
Current risk assessment strategies in type B aortic dissection are focused on anatomic parameters, although haemodynamic abnormalities that result in false lumen (FL) pressurization are thought to play a significant role in aortic growth. The objective of this study was to evaluate blood flow of the FL using 4D flow magnetic resonance imaging (MRI) and identify haemodynamic and anatomic factors that independently predict the rate of aortic growth. Patients with dissection of the descending thoraco-abdominal aorta (n = 18) were enrolled in a prospective observational study and underwent 4D flow MRI for haemodynamic assessment of the entry tear and FL. Anatomic parameters were obtained by magnetic resonance angiography and baseline computed tomography. False lumen ejection fraction (FL EF) was defined the ratio of retrograde flow rate at the dominant entry tear during diastole over the antegrade systolic flow rate. The median aortic growth rate was 3.5 mm/year (interquartile range 0.5–8.1 mm/year). Entry tear peak velocity was lower in patients with enlarging aortic dimensions (95.5 ± 24.1 vs 128.1 ± 37.4 cm/s, P = 0.039). After adjusting for co-variates FL EF (β = 0.15, P = 0.004), baseline maximal aortic diameter (β = 0.37, P = 0.001) and the entry tear distance from the left subclavian artery (β = 0.07, P = 0.016) were significant predictors of aortic growth rate. Beyond standard anatomic risk factors, FL EF is an independent predictor of aortic growth rate and may represent an intuitive, non-invasive method to estimate FL pressurization and improve patient-specific risk assessment in patients with type B aortic dissection.

1 January 2012 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
IVIsrael Valverde
Israel Valverde
SNSarah Nordmeyer
Sarah Nordmeyer
SUsergio uribe
sergio uribe
GGGerald Greil
Gerald Greil
FBFelix Berger
Felix Berger
PBPhilipp Beerbaum
Philipp Beerbaum
Systemic-to-pulmonary collateral flow (SPCF) may constitute a risk factor for increased morbidity and mortality in patients with single-ventricle physiology (SV). However, clinical research is limited by the complexity of multi-vessel two-dimensional (2D) cardiovascular magnetic resonance (CMR) flow measurements. We sought to validate four-dimensional (4D) velocity acquisition sequence for concise quantification of SPCF and flow distribution in patients with SV.

9 August 2023 in Medical Image Analysis
Verified
Journal Article
Closed access
PLPablo Arratia López
Pablo Arratia López
HMHernán Mella
Hernán Mella
SUsergio uribe
sergio uribe
DHDaniel Hurtado
Daniel Hurtado
FCFrancisco Sahli Costabal
Francisco Sahli Costabal

4 October 2017 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
JSJulio Sotelo
Julio Sotelo
LDLydia Dux-Santoy
Lydia Dux-Santoy
AGAndrea Guala
Andrea Guala
JRJose Rodríguez-Palomares
Jose Rodríguez-Palomares
AEArturo Evangelista
Arturo Evangelista
SUsergio uribe
sergio uribe