23 January 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
GBGeorg Bergmann
Georg Bergmann
ABAlwina Bender
Alwina Bender
FGFriedmar Graichen
Friedmar Graichen
JDJörn Dymke
Jörn Dymke
ARAntonius Rohlmann
Antonius Rohlmann
IKInes Kutzner
Ines Kutzner
The loads acting in knee joints must be known for improving joint replacement, surgical procedures, physiotherapy, biomechanical computer simulations, and to advise patients with osteoarthritis or fractures about what activities to avoid. Such data would also allow verification of test standards for knee implants. This work analyzes data from 8 subjects with instrumented knee implants, which allowed measuring the contact forces and moments acting in the joint. The implants were powered inductively and the loads transmitted at radio frequency. The time courses of forces and moments during walking, stair climbing, and 6 more activities were averaged for subjects with I) average body weight and average load levels and II) high body weight and high load levels. During all investigated activities except jogging, the high force levels reached 3,372–4,218N. During slow jogging, they were up to 5,165N. The peak torque around the implant stem during walking was 10.5 Nm, which was higher than during all other activities including jogging. The transverse forces and the moments varied greatly between the subjects, especially during non-cyclic activities. The high load levels measured were mostly above those defined in the wear test ISO 14243. The loads defined in the ISO test standard should be adapted to the levels reported here. The new data will allow realistic investigations and improvements of joint replacement, surgical procedures for tendon repair, treatment of fractures, and others. Computer models of the load conditions in the lower extremities will become more realistic if the new data is used as a gold standard. However, due to the extreme individual variations of some load components, even the reported average load profiles can most likely not explain every failure of an implant or a surgical procedure.

1 July 2001 in Journal of Biomechanics
Verified
Journal Article
Closed access
MMMichael Morlock
Michael Morlock
ESE Schneider
E Schneider
ABA Bluhm
A Bluhm
MVM Vollmer
M Vollmer
GBG Bergmann
G Bergmann
MHM Honl
M Honl

1 January 2010 in Bio-Medical Materials and Engineering
Verified
Journal Article
Closed access
GBG. Bergmann
G. Bergmann
FGF. Graichen
F. Graichen
ARA. Rohlmann
A. Rohlmann
ABA. Bender
A. Bender
BHB. Heinlein
B. Heinlein
MMMichael Morlock
Michael Morlock
The aim here was to define realistic load conditions for hip implants, based on in vivo contact force measurements, and to see whether current ISO standards indeed simulate real loads. The load scenarios obtained are based on in vivo hip contact forces measured in 4 patients during different activities and on activity records from 31 patients. The load scenarios can be adapted to various test purposes by applying average or high peak loads, high-impact activities or additional low-impact activities, and by simulating normal or very active patients. The most strenuous activities are walking (average peak forces 1800 N, high peak forces 3900 N), going up stairs (average peak forces 1900 N, high peak forces 4200 N) and stumbling (high peak forces 11,000 N). Torsional moments are 50% higher for going up stairs than for walking. Ten million loading cycles simulate an implantation time of 3.9 years in active patients. The in vitro fatigue properties of cementless implant fixations are exceeded during stumbling. At least for heavyweight and very active subjects, the real load conditions are more critical than those defined by the ISO standards for fatigue tests.

1 May 2011 in Journal of Biomechanics
Verified
Journal Article
Closed access
GBG. Bergmann
G. Bergmann
FGF. Graichen
F. Graichen
ABA. Bender
A. Bender
ARA. Rohlmann
A. Rohlmann
AHA. Halder
A. Halder
PWP. Westerhoff
P. Westerhoff

1 June 2017 in The Bone & Joint Journal
Verified
Journal Article
Closed access
IKI. Kutzner
I. Kutzner
ABA. Bender
A. Bender
JDJ. Dymke
J. Dymke
GDG. Duda
G. Duda
PRP. von Roth
P. von Roth
GBG. Bergmann
G. Bergmann
Aims: Tibiofemoral alignment is important to determine the rate of progression of osteoarthritis and implant survival after total knee arthroplasty (TKA). Normally, surgeons aim for neutral tibiofemoral alignment following TKA, but this has been questioned in recent years. The aim of this study was to evaluate whether varus or valgus alignment indeed leads to increased medial or lateral tibiofemoral forces during static and dynamic weight-bearing activities. Patients and Methods: Tibiofemoral contact forces and moments were measured in nine patients with instrumented knee implants. Medial force ratios were analysed during nine daily activities, including activities with single-limb support (e.g. walking) and double-limb support (e.g. knee bend). Hip-knee-ankle angles in the frontal plane were analysed using full-leg coronal radiographs. Results: The medial force ratio strongly correlated with the tibiofemoral alignment in the static condition of one-legged stance (R² = 0.88) and dynamic single-limb loading (R² = 0.59) with varus malalignment leading to increased medial force ratios of up to 88%. In contrast, the correlation between leg alignment and magnitude of medial compartment force was much less pronounced. A lateral shift of force occurred during activities with double-limb support and higher knee flexion angles. Conclusion: The medial force ratio depends on both the tibiofemoral alignment and the nature of the activity involved. It cannot be generalised to a single value. Higher medial ratios during single-limb loading are associated with varus malalignment in TKA. The current trend towards a ‘constitutional varus’ after joint replacement, in terms of overall tibiofemoral alignment, should be considered carefully with respect to the increased medial force ratio. Cite this article: Bone Joint J 2017;99-B:779–87.

1 July 2012 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
ABA. Bender
A. Bender
GBG. Bergmann
G. Bergmann
Forces measured in human joints vary considerably when an activity such as walking is carried out by different subjects or when it is repeated. ‘Typical’ standardised force–time patterns are needed to test and improve joint implants. Mechanically most important for their endurance are the magnitudes and times of force maxima and minima. They should equal the arithmetic means from the single measurements. Similar problems exist when evaluating other strongly varying signals, as in gait analysis. The new method to calculate typical signals (TSs) enhances existing dynamic time warping (DTW) procedures. It allows us to combine any number of signals. The sequence of input signals – used for calculating the TS – has only a minor influence. The accuracy of the method was tested numerically on signals for which the typical patterns could be defined exactly, and also on real joint forces that varied to different extents.